Daikin FXAQ40PAV1 Käyttöohje

Daikin Ilmastointi FXAQ40PAV1

Lue alta 📖 käyttöohje suomeksi merkille Daikin FXAQ40PAV1 (7 sivua) kategoriassa Ilmastointi. Tämä opas oli hyödyllinen 3 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/7
English
Deutsch
Français
Español
Italiano
Nederlands
Português
SYSTEM Inverter Air Conditioners
OPERATION MANUAL
MODELS
Wall-mounted type
FXAQ15PAV1
FXAQ20PAV1
FXAQ25PAV1
FXAQ32PAV1
FXAQ40PAV1
FXAQ50PAV1
FXAQ63PAV1
1 English
Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using the
air conditioner. It will tell you how to use the unit prop-
erly and help you if any trouble occurs. This manual
explains about the indoor unit only. Use it along with
the operation manual for the outdoor unit. After read-
ing the manual, file it away for future reference.
CONTENTS
1. SAFETY PRECAUTIONS............................................ 1
2. HOW TO ADJUST THE HORIZONTAL FAN
DIRECTION ANGLE.................................................... 3
3. HOW TO CLEAN THE AIR FILTER ............................ 4
4. HOW TO CLEAN THE AIR OUTLET AND
EXTERIOR .................................................................. 4
5. HOW TO CLEAN THE FRONT PANEL....................... 4
6. MAINTENANCE (FOR SERVICE PERSONNEL)........ 5
7. SOUND PRESSURE LEVEL....................................... 5
The original instructions are written in English. All
other languages are translations of the original
instructions.
Important information regarding the
refrigerant used
This product contains fluorinated greenhouse
gases covered by the Kyoto Protocol.
(1) GWP = global warming potential
Periodical inspections for refrigerant leaks may be
required depending on European or local legislation.
Please contact your local dealer for more information.
1. SAFETY PRECAUTIONS
To gain full advantage of the air conditioner’s functions and to
avoid malfunction due to mishandling, please read this oper-
ation manual carefully before use.
This product comes under the term “appliances not accessi-
ble to the general public”.
This appliance is intended to be used
by expert or trained users in shops, in
light industry and on farms, or for com-
mercial use by lay persons.
This appliance can be used by children
aged from 8 years and above and per-
sons with reduced physical, sensory or
mental capabilities or lack of experi-
ence and knowledge if they have been
given supervision or instruction con-
cerning use of the appliance in a safe
way and understand the hazards
involved. Children shall not play with
the appliance. Cleaning and user main-
tenance shall only be done by persons
described in manual.
Drain pipe
Name plate
Air inlet
(front and top of main unit)
Air filter
(Inside intake vent)
Refrigerant pipe transmission
wiring
Remote controller
Horizontal flaps
(vertical air outlet direction adjustment flaps)
Louver
(horizontal air outlet direction
adjustment
flaps)
Air outlet Ground wire
Conducts electricity from the
unit into the ground to prevent
electric shock.
(Indoor unit model name)
Packaging materials
If any packaging materials are
included, please remove
before operating.
Power supply wiring
Refrigerant type R410A
GWP(1) value 1975
English 2
The appliance is not intended for use by unattended
young children or persons who are incompetent to oper-
ate air conditioners.
It may result in injury or electric shocks.
This manual classifies the precautions into WARNINGS
and CAUTIONS. Be sure to follow all the precautions
below: They are all important for ensuring safety.
WARNING....... Indicates a potentially hazardous situa-
tion which, if not avoided, could result in
death or serious injury.
CAUTION ........ Indicates a potentially hazardous situa-
tion which, if not avoided, may result in
minor or moderate injury.
It may also be used to alert against
unsafe practices.
After reading, keep this manual in a convenient place
so that you can refer to it whenever necessary. If the
equipment is transferred to a new user, be sure also to
hand over the manual.
WARNING
When the air conditioner is malfunctioning (giving
off a burning odor, etc.), turn off the power to the air
conditioner and contact your local dealer.
Continued operation under such circumstances may
result in a failure, electric shocks or a fire.
Consult your local dealer regarding modification,
repair and maintenance of the air conditioner.
Improper workmanship may result in water leakage,
electric shocks or a fire.
Be sure to use fuses with the correct ampere read-
ing.
Do not use improper fuses, copper or other wiring as a
substitute, as this may result in electric shocks, a fire,
injury or damage to the air conditioner.
Consult your local dealer if the air conditioner sub-
merges owing to a natural disaster, such as a flood
or typhoon.
Do not operate the air conditioner in that case, or other-
wise a malfunction, electric shocks, or a fire may result.
Start or stop the air conditioner with the remote con-
troller. Never use the power circuit breaker for this
purpose.
Otherwise, it may cause a fire or water leakage. Further-
more, if an automatic restart control is provided against
power failure and the power is recovered, the fan will
rotate suddenly and may cause injury.
Do not use the air conditioner in the atmosphere
contaminated with oil vapor, such as cooking oil or
machine oil vapor.
Oil vapor may cause crack damage to the air conditioner,
electric shocks, or a fire.
Do not use flammable materials (e.g., hairspray or
insecticide) near the air conditioner.
Do not clean the air conditioner with organic sol-
vents such as paint thinner.
The use of organic solvents may cause crack damage to
the air conditioner, electric shocks, or a fire.
Do not use the air conditioner in places with exces-
sive oily smoke, such as cooking rooms, or in places
with flammable gas, corrosive gas, or metal dust.
Using the air conditioner in such places may cause a fire
or air conditioner failures.
Beware of a fire in case of refrigerant leakage.
If the air conditioner is not operating correctly, i.e. not
generating cool or warm air, refrigerant leakage could be
the cause. Consult your local dealer for assistance. The
refrigerant used for the air conditioner is safe and nor-
mally does not leak. However, if the refrigerant leaks and
gets in contact with a naked burner, heater or cooker, it
may generate hazardous compounds. Turn off the air
conditioner and call your local dealer. Turn on the air con-
ditioner after the qualified service person makes sure to
confirm that the leakage is repaired.
Do not place objects, including rods, your fingers,
etc., in the air inlet or outlet.
Injury may result due to contact with the air conditioner’s
highspeed fan blades.
Consult your local dealer regarding cleaning the
inside of the air conditioner.
Improper cleaning may cause breakage of plastic parts,
water leakage and other damage as well as electric
shocks.
Be aware that prolonged, direct exposure to cool or
warm air from the air conditioner, or to air that is too
cool or too warm can be harmful to your physical
condition and health.
Consult your local dealer about installation work.
Doing the work yourself may result in water leakage,
electric shocks or a fire.
Contact professional personnel about attachment of
accessories and be sure to use only accessories
specified by the manufacturer.
If a defect results from your own workmanship, it may
result in water leakage, electric shocks or a fire.
Consult your local dealer regarding relocation and
reinstallation of the air conditioner.
Improper installation work may result in leakage, electric
shocks or a fire.
Be sure to earth the air conditioner.
Do not earth the air conditioner to a utility piping, light-
ning conductor or telephone earth lead.
Imperfect earthing may result in electric shocks or a fire.
A high surge current from lightning or other sources may
cause damage to the air conditioner.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in
electric shocks or a fire.
Be sure to use a dedicated power supply for the air
conditioner.
The use of any other power supply may cause heat gen-
eration, a fire, or air conditioner failures.
Consult your local dealer regarding what to do in
case of refrigerant leakage.
When the air conditioner is installed in a small room, it is
necessary to take proper measures so that the amount of
any leaked refrigerant does not exceed the concentration
limit in the event of a leakage. Otherwise, this may lead to
an accident due to oxygen depletion.

Tuotetiedot

Merkki: Daikin
Kategoria: Ilmastointi
Malli: FXAQ40PAV1

Tarvitsetko apua?

Jos tarvitset apua merkille Daikin FXAQ40PAV1 esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Ilmastointi Daikin Käyttöohjeet

Ilmastointi Käyttöohjeet

Viimeisimmät Ilmastointi Käyttöohjeet