Lego NINJAGO 71820 Käyttöohje
Lue alta 📖 käyttöohje suomeksi merkille Lego NINJAGO 71820 (4 sivua) kategoriassa Lelut. Tämä opas oli hyödyllinen 2 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä
Sivu 1/4
KC-C Reels
Safety Warnings and Operation
For use with the DLRO2
User Guide
1. WARNING
These warnings must be read and understood before use:
The lead set is intended only for use with the Megger DLRO2; it must not
be used with other measuring instruments
Read the safety warnings provided with the DLRO2 before use
Before use, inspect the lead set for wear and damage. Probes, wires
and connectors must be in good order, clean and dry with no broken or
cracked insulation
Damaged lead sets must NOT be used
The lead set is rated only for connection to low voltage circuits: <30 V at a
maximum of 2 A
The safe connection rating is that of the lowest rated item in the
measurement circuit which comprises instrument, probe assembly and
accessories
Do NOT connect this lead set to mains circuits
The lead set is rated for indoor and outdoor use
Operating environment between 0 °C and +50 °C, <95% RH
The safe altitude for use is ≤3,000 m above sea level
If the lead set is used in a manner not specified by the manufacturer, the
protection provided by the test lead may be impaired
Mass: KC100C: 7.6 kg. KC50C and KC50E: 4.4 kg
www.megger.com 2
WARNING
2. Operation
This test lead is intended for use with a Megger DLRO2 to measure
bonded conductors. For example, the resistance of lightning receptors to
earth for large equipment in production, or in-situ during commissioning
or maintenance, or following repair
The KC series enable construction of long test leads in 50 m increments
suitable for testing large structures.
A test lead will consist of the appropriate instrument connector and asset
clips at each end of a KC50C (50 m) or KC100C (100 m) lead. One or two
KC50E (50 m) extension leads may be added to the assembly to extend the
length.
For assemblies using more than one cable, the KC50E extension reel
should be unwound and removed from its drum first: lift the extension
cable connector from the slot in the drum and pass it though the hole in
the drum wall. Connect the extension to the next cable to be unwound
and repeat the process.
Ensure that 4 mm test terminals are correctly connected to the DLRO2:
mating red to red and black to black
All tests must be carried out in accordance with the equipment
manufacturers’ procedures and test limits
Before testing tall structures, ensure that any static potential is fully
discharged by connecting an additional ground wire to the installed
lightning protection cable at the base of the structure
When working with tall structures, consider the risks from carrying heavy
equipment and unreeling cables at height. Arrange a safe procedure to
protect those working below and at height during setting-up, testing and
removing the test connections, especially when bad weather, high winds
or precipitation add to the risk
www.megger.com 3
Operation
Tuotetiedot
Merkki: | Lego |
Kategoria: | Lelut |
Malli: | NINJAGO 71820 |
Tarvitsetko apua?
Jos tarvitset apua merkille Lego NINJAGO 71820 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Lelut Lego Käyttöohjeet
9 Tammikuuta 2025
9 Tammikuuta 2025
9 Tammikuuta 2025
29 Joulukuuta 2024
29 Joulukuuta 2024
29 Joulukuuta 2024
29 Joulukuuta 2024
29 Joulukuuta 2024
29 Joulukuuta 2024
29 Joulukuuta 2024
Lelut Käyttöohjeet
- Lelut Denver
- Lelut IKEA
- Lelut SereneLife
- Lelut GoGEN
- Lelut Archos
- Lelut Sharper Image
- Lelut Chipolino
- Lelut Backyard Discovery
- Lelut Valley Dynamo
- Lelut Bullet
- Lelut VTech
- Lelut Pardini
- Lelut Lionelo
- Lelut Playmobil
- Lelut Rovo Kids
- Lelut Plum
- Lelut Woodlii
- Lelut Sunnydaze Decor
- Lelut WowWee
- Lelut Hurtle
- Lelut Merax
- Lelut Zume
- Lelut Hathaway
- Lelut Huffy
- Lelut MD Sports
- Lelut Hacienda
Viimeisimmät Lelut Käyttöohjeet
9 Tammikuuta 2025
9 Tammikuuta 2025
9 Tammikuuta 2025
9 Tammikuuta 2025
9 Tammikuuta 2025
9 Tammikuuta 2025
9 Tammikuuta 2025
8 Tammikuuta 2025
4 Tammikuuta 2025
4 Tammikuuta 2025