PCE Instruments PCE-325D Käyttöohje
PCE Instruments
Mittauslaitteet
PCE-325D
Lue alta 📖 käyttöohje suomeksi merkille PCE Instruments PCE-325D (9 sivua) kategoriassa Mittauslaitteet. Tämä opas oli hyödyllinen 5 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä
Sivu 1/9
© PCE Instruments
PCE- / PCE-325D Sound Level Meter 325
User Manual
User manuals in various languages (français,
italiano, español, português, nederlands, türk, polski,
русский, 中文
中文
中文
中文中文) can be found by using our
product search on: www.pce-instruments.com
Last change: 20 June 2024
v1.0
English
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Technical specication 2 ........................................................................
3 Delivery Scope ...................................................................................... 2
4 Device description ................................................................................ 3
4.1 Key description 3 .................................................................................................................
4.2 Display ............................................................................................................................. 3
5 Operating instructions 4 .........................................................................
5.1 Switch the meter on/o ..................................................................................................... 4
5.2 Select A/C frequency weighting ........................................................................................ 4
5.3 Select F/S Mode ............................................................................................................... 4
5.4 Selecting decibel ranges .................................................................................................. 4
5.5 Measurement ................................................................................................................... 4
5.6 MAX/MIN mode ................................................................................................................ 5
5.7 Hold data 5 ..........................................................................................................................
5.8 Recording mode (PCE-325D only) ................................................................................... 5
5.9 Auto Power O ................................................................................................................. 5
5.10 Data recording and software installation ........................................................................... 5
6 Calibration 6 .............................................................................................
7 Maintenance and cleaning ................................................................... 6
7.1 Cleaning and storage ....................................................................................................... 6
7.2 Charging the battery ......................................................................................................... 6
8 Contact ................................................................................................... 6
9 Disposal ................................................................................................. 6
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the rst time. The
device may only be used by qualied personnel and repaired by PCE Instruments personnel.
Damage or injuries caused by non-observance of the manual are excluded from our liability and
not covered by our warranty.
• The device must only be used as described in this instruction manual. If used otherwise,
this can cause dangerous situations for the user and damage to the meter.
• The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
• Do not expose the device to shocks or strong vibrations.
• The case should only be opened by qualified PCE Instruments personnel.
• Never use the instrument when your hands are wet.
• You must not make any technical changes to the device.
• The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
• The device must only be used with accessories from PCE Instruments or equivalent.
• Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
• Do not use the instrument in explosive atmospheres.
• The measurement range as stated in the specications must not be exceeded under
any circumstances.
• Non-observance of the safety notes can cause damage to the device and injuries to
the user.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of
business.
Tuotetiedot
Merkki: | PCE Instruments |
Kategoria: | Mittauslaitteet |
Malli: | PCE-325D |
Tarvitsetko apua?
Jos tarvitset apua merkille PCE Instruments PCE-325D esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Mittauslaitteet PCE Instruments Käyttöohjeet
24 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
Mittauslaitteet Käyttöohjeet
- Mittauslaitteet Kogan
- Mittauslaitteet PeakTech
- Mittauslaitteet Clean Air Optima
- Mittauslaitteet CSL
- Mittauslaitteet Kern
- Mittauslaitteet Einhell
- Mittauslaitteet Reely
- Mittauslaitteet Joy-it
- Mittauslaitteet Basetech
- Mittauslaitteet Gossen Metrawatt
- Mittauslaitteet TFA
- Mittauslaitteet Extech
- Mittauslaitteet Sonel
- Mittauslaitteet Flir
- Mittauslaitteet Testo
Viimeisimmät Mittauslaitteet Käyttöohjeet
27 Lokakuuta 2024
26 Lokakuuta 2024
25 Lokakuuta 2024
25 Lokakuuta 2024
24 Lokakuuta 2024
22 Lokakuuta 2024
22 Lokakuuta 2024
21 Lokakuuta 2024
21 Lokakuuta 2024
21 Lokakuuta 2024