PCE Instruments PCE-SLD 10 Käyttöohje

Lue alta 📖 käyttöohje suomeksi merkille PCE Instruments PCE-SLD 10 (24 sivua) kategoriassa Mittauslaitteet. Tämä opas oli hyödyllinen 3 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/24
SD card real time data recorder
4 - 20 mA output
SOUND LEVEL DATA RECORDER
Model : PCE-SLD 10
Your purchase of this
SOUND LEVEL DATA RECORDER
with 4 - 20 mA output, marks a
step forward for you
into the eld of
precision measurement.
Although this meter a
complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.
OPERATION MANUAL
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Unit 11
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.co.uk
TABLE OF CONTENTS
1. FEATURES..............................................................................
1
2. SPECIFICATIONS...................................................................
2
3. FRONT PANEL DESCRIPTION..............................................
6
4. MEASURING PROCEDURE...................................................
7
4-1 Sound Pressure Level
Measurements (SPL)...........................
7
4-2 Sound Pressure Measurements Range select…………………
7
4-3 Sound Frequency weighting select ..........................................
7
4-4 Sound Time Weighting select ………............................………
8
4-5 Data Hold.................................................................................
8
4-6 Data Record ( Max., Min. reading )..........................................
8
4-7 LCD Backlight ON/OFF……………………………………………
9
4-8 Time check..............................................................................
9
4-9 4-20 mA output…………………………………………..…………
9
5. DATALOGGER........................................................................
10
5-1 Preparation before execute datalogger function.......................
10
5-2 Auto Datalogger ( Set sampling time
5 seconds )...............
10
5-3 Check time and sampling time information...............................
12
5-4 SD Card Data structure............................................................
12
6. Saving data from the SD card to the computer........................
13
7. ADVANCED SETTING.............................................................
15
7-1 Set clock time ( Year/Month/Date, Hour/Minute/ Second ).......
15
7-2 Set sampling time ....................................................................
16
7-3 Auto power OFF management ................................................
16
7-4 Set beeper Sound ON/OFF......................................................
17
7-5 Decimal point of SD card setting..............................................
17
7-6 SD memory card format...........................................................
18
8. POWER SUPPLY FROM
DC ADAPTER................................
19
9. BATTERY REPLACEMENT.....................................................
19
10. RS232 PC SERIAL INTERFACE
...........................................
19
CALIBRATION ........................................................................
21
12. FREQUENCY WEIGHTING CHARACTERISTICS
OF A & C NETWORKS..........................................................
21
13. TONEBURST RESPONSE (FAST & SLOW)
CHARACTERISTICS.............................................................
22
1. FEATURES
* Frequency and Time weighting are designed to meet IEC 61672 class 2.
* A & C weighting networks comply with standards.
* LCD is dot-matrix with backlight and easy reading.
* Data-logger and Sound level meter.
* 0.5" standard microphone head.
* Time weighting (Fast & Slow) dynamic characteristic modes.
* Condenser microphone for high accuracy & long-term stability.
* Memory function to store the Max. & Min. value.
* Hold functions.
* Peak Hold functions.
* Real time Datalogger
Records device of an external
memory device (SD memory card ) ,Real time Datalogger, it Built-in
Clock and Calendar, real time data recorder, sampling time set
from 5,10,30,60,120,300,600,1800,3600 seconds.
* Innovation and easy operation, computer is not need to
setup extra software, after execute datalogger, just take
away the SD card from the meter and plug in the SD card
into the computer, it can download the all the measured
value with the time information ( year/month/date/
hour/minute/second ) to the Excel directly, then user can
make the further data or graphic analysis by themselves.
* SD card capacity : 1 GB to 16 GB.
* Can default auto power off or manual power off.
* 4-20 mA analog output.
* Microcomputer circuit, high accuracy.
* Power by UM4/AAA ( 1.5 V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface.
* Heavy duty & compact housing case.
1

Tuotetiedot

Merkki: PCE Instruments
Kategoria: Mittauslaitteet
Malli: PCE-SLD 10

Tarvitsetko apua?

Jos tarvitset apua merkille PCE Instruments PCE-SLD 10 esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Mittauslaitteet PCE Instruments Käyttöohjeet

Mittauslaitteet Käyttöohjeet

Viimeisimmät Mittauslaitteet Käyttöohjeet

Flir

Flir Cx5 Käyttöohje

27 Lokakuuta 2024
Kern

Kern FL 1KG Käyttöohje

25 Lokakuuta 2024
PeakTech

PeakTech 6193 Käyttöohje

25 Lokakuuta 2024
Testo

Testo Saveris 2 Käyttöohje

24 Lokakuuta 2024
Extech

Extech 380941 Käyttöohje

22 Lokakuuta 2024
Extech

Extech 380926 Käyttöohje

22 Lokakuuta 2024
Kern

Kern FA 50 Käyttöohje

21 Lokakuuta 2024
Kern

Kern DB 500-2 Käyttöohje

21 Lokakuuta 2024
Kern

Kern 289-100 Käyttöohje

21 Lokakuuta 2024