Instruction Manual
MA 10061
Please read this instruction manual thoroughly to fully understand the features and functions so that you
can enjoy the safe and correct operation of this unique product.
By following the operating instructions, you also avoid damage to the equipment and the risk of
voiding warranty rights through misuse.
The manufacturer and supplier will not be held liable for actions due to failure
to comply with this instruction manual or from data inaccuracies that may
occur with this product!
Pay particular attention to the safety instructions!
Keep the manual for further reference!
Contents of delivery
• 1 x Gateway
• 1 x AC 20V-Adapter
• 1 x LAN-Cable
• 1 x Thermo-/Hygro-Sensor with 2 x C-batteries
• 1 x Rain gauge with 2 x AA-batteries
• 1 x Wind sensor with solar cell (2 x AAA-batteries built in rechargeable alkaline cells (RAM))
• Mounting material
• Instruction manual
Usage
•
The weather station consists of a gateway with corresponding measuring units (transmitters) that measure
weather data such as temperature, humidity, wind speed, wind direction, and rainfall. The data can be accessed
via internet from a device with iOS or Android operating systems by using the Mobile-Alerts App.
Safety Notes:
•
The product is designed exclusively for the usage described above. Don’ t use the product in another way than
described in this manual.
•
For reasons of safety and operation, alterations to this device are strictly prohibited.
Risk of fatal injury from electric shock
• Connect the gateway adapter only to a properly installed socket of 230 V.
• Keep the gateway and power adapter away from contact with water or high humidity. Both should only be used
in dry, interior spaces.
•
Do not use the device if the housing or the cable of the device or the power supply are damaged.
•
Store idle equipment out of the reach of children and do not allow persons unfamiliar with the equipment or
these instructions to operate the equipment.
•
The power wall outlet should be close to the system and easily accessible.
•
Remove the plug from the mains, If you are not going to use the device for a longer period of time
•
Use the power cord and plug that are included only.
•
Place the power cord so that it does not come into contact with sharp or hot objects.
Caution! Danger of injury:
•
Always keep batteries and appliances out of reach of small children.
•
Do not recharge, short-circuit, heat, burn or disassemble batteries
.
Risk of explosion!
•
Batteries contain harmful acids. To avoid damage caused by leakage of the battery uid, replace weak batteries
as soon as possible. Never use dierent types of batteries together or mix old and new batteries. When replacing
the leaking batteries wear chemical resistant gloves and safety goggles!
Important information on product safety!
•
Do not expose the device to extreme temperatures, vibration or shock.
Components
Gateway MA 10251 MA 10650 MA10660
Gateway
The gateway is the main unit. It collects all data of the sensor units, which can be accessed via internet from a
smartphone or tablet with Mobile-Alerts App on an iOS or Android operating system.
Sensors
The sensors transmit the readings wireless via radio (868 MHz) within a range of max. 100 m (free eld) to the
gateway. The included sensors are a temperature/ humdity sensor with repeater function for wind data
(MA10251), wind direction / wind speed sensor (MA10660) and a rain gauge (MA10650). It is possible to connect
further Mobile-Alerts with the gateway.
Requirements
The Mobile-Alerts Gateway collects weather data and transmits them to a server. For this purpose, an Internet
connection is necessary. You will also need a router with network socket (LAN - RJ45).
To view the weather data you need an internet enabled device (for example, smartphone) with an active Internet
connection and the Mobile Alerts App.
Installation
Download the App
Download the app from "Apple App Store" or "Google Play". MOBILE-ALERTS
Connect the Gateway
Connect the gateway to power supply using the supplied AC adapter. Connect included LAN cable with the
gateway and your router. After about 10 seconds, the Gateway is in operation. The LED will turn static green.
If no DHCP server is available in your network, you can congure the gateway in the app under the point
“Settings” manually.
Important: The Gateway should always be put into operation before starting the sensors!
Installation of Sensors
Setting up the thermo / hygro transmitter
•
Pull o the protection cap and open the battery compartment of the temperature sensor and put in 2x C
batteries with the correct polarity.
•
Close the lid of the battery compartment and replace the protection cap.
Setting up the rain gauge
•
Open the cover of the rain gauge by counter-rotating the base to the lid and then remove the cover.
•
Remove the transport securing of the seesaw. The seesaw should be freely moveable forward and backward
now.
•
Remove the lid of the battery compartment on the bottom of the sensor by loosening the screw.
•
Insert 2x AA batteries with correct polarity and close the lid of the battery compartment by tightening the screw.
Setting up the wind sensor
•
Remove the protective lm from the solar panel
•
Press the reset button on the bottom of the sensor using the supplied plastic rod
Add sensors
•
Open the app, dashboard is displayed.
•
The sensors with the prex "Sample" are only for demonstration purposes and can be deleted.
•
Tap "Add new sensor" and scan the QR code on the back or bottom of the temperature sensor.
•
Then set a name for the sensor. To set a name, select the transmitter and then tap on the left area of the pencil
icon in the upper right.
•
Conrm the name by pressing the Enter button, then tap Back.
Read measurements
•
Now you can read the measurements on your mobile phone.
•
For more information on using the app and sensor-specic settings can be found in the app under "Info".
Mounting Sensors
Below we will give you instructions for placement and mounting of the measuring units:
•
Ensure that all of the sensor data can be received by the gateway at the intended
mounting locations. Trees, metal surfaces, walls and electronic devices can interfere with transmission.
•
Please check whether the stations are accessible for cleaning and maintenance easy too.
•
The sensors should be cleaned regularly, as dirt residues can aect the measurements.
Tuotetiedot
Merkki: | Techno Line |
Kategoria: | Sääasema |
Malli: | MA 10061 |
Tarvitsetko apua?
Jos tarvitset apua merkille Techno Line MA 10061 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Sääasema Techno Line Käyttöohjeet
3 Tammikuuta 2025
26 Joulukuuta 2024
26 Joulukuuta 2024
26 Joulukuuta 2024
26 Joulukuuta 2024
26 Joulukuuta 2024
26 Joulukuuta 2024
26 Joulukuuta 2024
26 Joulukuuta 2024
26 Joulukuuta 2024
Sääasema Käyttöohjeet
- Sääasema La Crosse Technology
- Sääasema Sencor
- Sääasema EMOS
- Sääasema Brandson
- Sääasema Muse
- Sääasema TFA
- Sääasema Davis
- Sääasema GlobalTronics
- Sääasema Goddess
- Sääasema EQ-3
Viimeisimmät Sääasema Käyttöohjeet
29 Joulukuuta 2024
29 Joulukuuta 2024
29 Joulukuuta 2024
29 Joulukuuta 2024
27 Joulukuuta 2024
25 Joulukuuta 2024
14 Joulukuuta 2024
14 Joulukuuta 2024
14 Joulukuuta 2024
14 Joulukuuta 2024