02913 - LTE thermostat
SMART CLIMA
Electronic LTE thermostat for local control and advanced remote temperature management
via View App, heating and air conditioning in ON/OFF and PID mode, class I temperature
control device (contribution 1%) in ON/OFF mode, class IV (contribution 2%) in PID mode,
configuration via View App on standard Bluetooth technology, 1 additional output and 1
digital input, 1 relay output 5(2) A 240 V~, power supply 100-240 V~ 50/60 Hz, white LED
backlighting, surface mounting, white.
Download the View App from the stores onto the tablet/smartphone you will be
using for configuration.
You will also need:
Amazon Alexa, Google Assistant voice assistants for possible voice operation
CONFIGURATION IN
1. Create your Administrator or Installer account on MyVimar (on-line).
2. Wire the thermostat.
3. Start the View App and log in with the credentials you just created.
4. To associate the thermostat:
• In the event of new systems, select “Create smart system” and give it a name. Select the
smart system you just created “Customise” “Smart devices” “Add a device”
“VIMAR Smart Thermostat” “Start”
• In the case of an existing system, select the smart system “Customise” “Smart devices”
“Add a device” “VIMAR Smart Thermostat” “Start”
• Press button B for 5 s; activate the Bluetooth connection on your tablet/smartphone and
approach the thermostat
• Select “Proceed” and enter the APN of your phone operator following the instructions pro-
vided by the wizard
Main APN
TIM ibox.tim.it
Vodafone web.omnitel.it
Wind3 internet.it
Iliad iliad
• Name the thermostat and the actuator of the auxiliary output and then set the time zone
• Go to the “Smart Devices” section and set the thermostat parameters
For details please refer to the manual entitled “Programming thermostats 02912-02913”
available for download from www.vimar.com
OPERATION WITHOUT CONFIGURATION VIA APP.
If configuration is not done via the View App, the thermostat is designed to accommodate
operation in manual mode.
RESETTING THE THERMOSTAT
The reset restores the factory settings. Within the first 5 minutes within which it is powered, press
button B for 30 s.
INSTALLATION RULES.
• Installation and configuration must be carried out by qualified persons in compliance with the
current regulations regarding the installation of electrical equipment in the country where the
products are installed.
• The C-NO contact of the relay must be protected against overloads by installing a device, fuse
or automatic 1-way switch, with a rated current not exceeding 10 A.
• Do not connect a SELV circuit to the NO-C, IN-N and L-1 (auxiliary output) terminals as there
is no double insulation compared to the L-N terminals.
• The device must be installed at a height of 1.5 m above floor level, in a suitable position for the
correct detection of the room temperature, avoiding installation in recesses, behind doors and
curtains, areas affected by heat sources or subject to the flow of forced heating/cooling venti-
lation sources or affected by atmospheric factors. Avoid in particular installation on perimeter
walls or in association with devices which generate heat (e.g. dimmers or lamps).
IMPORTANT WARNINGS
• The LTE connection varies depending on the phone operator; check in advance the one in
your area which guarantees best coverage and purchase the corresponding SIM card.
• We recommend you use a SIM card with a data contract with traffic of at least 50 MB/
month.
• Before inserting the SIM card in the thermostat, disable the PIN code prompt.
To do this, insert the SIM card in your smartphone and follow the instructions provided to
disable the PIN.
CHARACTERISTICS.
• Rated supply voltage: 100-240 V~, 50/60 Hz.
• Consumption at 100 V~:
- brightness L1 (low) and relay OFF 0.3 W
- brightness L3 (high) and relay ON 0.85 W
• Consumption at 240 V~:
- brightness L1 (low) and relay OFF 0.5 W
- brightness L3 (high) and relay ON 1 W
• Bluetooth technology:
- RF transmission power: < 100 mW (20 dBm)
- Frequency range: 2400-2483.5 MHz
• Transmission bands:
- B1 (2100MHz)
- B3 (1800MHz)
- B7 (2600MHz)
- B8 (900MHz)
- B20 (800MHz)
• Terminals:
- 2 (L and N) for line and neutral
- 2 for digital input 120 - 240 V~ for alarm signalling (for instance boiler shutdown)
Maximum length of the 30 m contact connection cable
- 2 (NO-C) for relay output with voltage-free contact: 5(2) A 240 V~
- 2 for output 100 mA 120 - 230 V~ to control an auxiliary relay (for instance to switch a boiler
or a light on/off)
• 2 front buttons with rocking action for control and settings.
• 1 button (positioned at the bottom) for configuration and reset.
• Side LEDs:
- 2 on the left for signalling Cloud connection and LTE network connection
- 3 on the right for signalling ON/OFF, relay state and auxiliary output state
• White LED display for displaying temperature, set point and configuration state signalling.
• Current settable setpoint: 4 °C ÷ 40 °C.
• Temp. measurement precision (integrated probe): 0.5°C between +15°C and 30°C, 0.8°C at
the extremes
• For use for Heating/Air Conditioning (winter/summer).
• Operating modes: Automatic, Manual, Reduction, Absence, Protection, Off, Timed Manual.
• Temperature control algorithms: configurable PID or ON/OFF.
• Operating temperature: T40 (0 °C +40 °C) (indoor use).÷
• Protection degree: IP20.
• ErP classification (EU Reg. 811/2013): - ON/OFF: class I, contribution 1%. - PID: class IV,
contribution 2%.
• Device in class II
• Number of manual cycles: 3,000
• Number of automatic cycles: 100,000
• Type of contact opening: micro-disconnection
• Type of action: 1.C
• Tracking index: PTI175
• Degree of pollution: 2
• Rated pulse voltage: 4000 V
• Software class: A
• Reading resolution: 0.1 °C
• Settings resolution: 0.1 °C from App and ± 0.5 °C from device
• Update of temperature displayed: every 10 s
• Room temperature display: 0 °C +40 °C
• Hysteresis adjustable via App: from 0.1 °C to 1 °C
• Hourly temperature setting (via App)
• Room temperature during transportation: -25 °C +60 °C
• Clock error: ≤ 1 s per day
• Configuration via View App using Bluetooth technology
• Controllable via View App, Amazon Alexa and Google Assistant voice assistants.
• Dimensions: 106 x 118 x 23.5 mm.
OPERATION.
Using the View App, making use of the Internet connection
the following can be set:
• Time schedules (times and temperature levels T1, T2 and T3)
• Setpoint for all operating modes (Manual, Reduction, Absence, Protection). The operating
mode can be changed from the View App after one ON/OFF cycle
• Manual operation time: between 1 min and 23 hours (with 1-min steps); default = 60 min
• Lighting in standby: high, medium, low, off with default = medium
• Temperature calibration for heating: between -5°C and +5°C with default = 0°C
• Temperature calibration for air conditioning: between -5°C and +5°C with default = 0°C
• Relay output status: normally open, normally closed; default = normally open
• Auxiliary output state: ON/OFF, timed.
• Control type: On/Off, PID; default = On/Off
• Hysteresis for On/Off control: between 0.1°C and 1°C; default = 0.2°C
• Proportional band for PID control: between 0.5°C and 5°C; default = 3°C
• Integrative time for PID control: between 5 min and 120 min; default = 20 min
• Derivative time for PID control: between 0 and 255 s, disabled; default = 0
• Cycle time for PID control: between 10 min and 30 min; default = 10 min
In the event of a power outage, once the power is restored, the thermostat restarts with the
operating mode prior to the outage. If the mode set was “Automatic” the thermostat will restart
in “Manual” mode and the first time it reconnects to the Cloud, it will synchronise the time/date
again and then switch to “Automatic” mode.
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
02913 03 2206
02913 - LTE thermostat
SMART CLIMA
VIEWS
• Short press = adjustment of set point from 4°C to 40°C in steps of 0.5°C
• Long press (5 s) = if on standby the thermostat is switched off; if switched OFF
the thermostat is switched on
A
Display
• bt = thermostat in Bluetooth configuration
• off = thermostat off; on = thermostat on
• °C = degrees Celsius; °F = degrees Fahrenheit
• animation from the bottom up = Heating
• animation from the top down = Air conditioning
• Rst = thermostat reset
• PIN = PIN entry prompt
• Alr, Con, Cld, ltE, etc. = alarms
B
• Short press = degrees Celsius/Fahrenheit selection
• Long press (5 s) = the thermostat enters the configuration phase (bt)
• Prolonged press (30 s) within the first 5 min of powering = thermostat reset (Rst)
LED indications
• ON green = Cloud correctly connected
• ON red = Cloud not connected
• ON green = LTE network connected
• ON red = LTE network not connected
• ON green = ON thermostat
• OFF = OFF thermostat
• ON white = Active relay
• ON white = Auxiliary output active
USE.
The thermostat display shows the current temperature; when you use “ ” and “ ” the set
point being set during the action is displayed.
REGULATORY COMPLIANCE.
RED Directive. RoHS directive. ErP directive.
Standards EN 60730-2-7, EN IEC 60730-2-9, EN 300 328, EN 301 489-17, EN 301 908-13, EN
301 489-52, EN 62311, EN IEC 63000.
Temperature control device regulation (EU) no. 811/2013.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text
of the EU declaration of conformity is on the product sheet available on the following website:
www.vimar.com
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE - User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life must be collected separately
from other waste. The user must therefore hand the equipment at the end of its life cycle over to the appropriate municipal centres for the
differentiated collection of electrical and electronic waste. As an alternative to independent management, you can deliver the equipment you
want to dispose of free of charge to the distributor when purchasing a new appliance of an equivalent type. You can also deliver electronic
products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to electronics distributors with a sales area
of at least 400 m
2. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal of the old
equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of reusing and/
or recycling materials used in manufacture.
The Apple, iPhone and iPad logos are trademarks of Apple Inc., registered in the United States and in other Countries and
Regions. App Store is a service trademark of Apple Inc.
Google is a trademark of Google LLC.
Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
Alarms
Alr Alarm generated by the wired contact (for instance Boiler shutdown)
Con No connection to the GSM network
Cld No connection to the Cloud
ltE
• SIM missing
• SIM PIN request
• SIM credit depleted
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
02913 03 2206
CONNECTION WITH CIRCULATION PUMPS, BURNERS, SOLENOID VALVES
VIA LE V IC ENZ A 1 4
ITALY
360 63 MARO S T ICA VI
N NINL L NO C1
VIA
ITA
36
N NINL L NO C1
Auxiliary relay
Contact for alarm signalling*
* Generates an alarm notification but does not deactivate the output relay (NO-C)
TYPES OF INSTALLATION
Tuotetiedot
Merkki: | Vimar |
Kategoria: | Termostaatti |
Malli: | 02913 |
Tarvitsetko apua?
Jos tarvitset apua merkille Vimar 02913 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Termostaatti Vimar Käyttöohjeet
12 Joulukuuta 2024
12 Joulukuuta 2024
11 Joulukuuta 2024
11 Joulukuuta 2024
11 Joulukuuta 2024
11 Joulukuuta 2024
11 Joulukuuta 2024
10 Joulukuuta 2024
10 Joulukuuta 2024
10 Joulukuuta 2024
Termostaatti Käyttöohjeet
- Termostaatti ORNO
- Termostaatti Siemens
- Termostaatti EBERLE
- Termostaatti Danfoss
- Termostaatti Heatit
- Termostaatti STI
- Termostaatti Drayton
- Termostaatti Jung
- Termostaatti Ambiano
- Termostaatti Xavax
- Termostaatti Remeha
- Termostaatti Heatmiser
- Termostaatti Hive
- Termostaatti GENERAL Life
- Termostaatti HomePilot
- Termostaatti Delta Dore
- Termostaatti Fenix
- Termostaatti H-Tronic
- Termostaatti Junkers
- Termostaatti Gewiss
- Termostaatti Ferroli
- Termostaatti Honeywell
- Termostaatti Horstmann
- Termostaatti Landis Gyr
- Termostaatti Salus
- Termostaatti Vaillant
- Termostaatti Theben
- Termostaatti Amfra
- Termostaatti Grasslin
- Termostaatti ELKO
- Termostaatti Orbis
- Termostaatti Vemer
- Termostaatti Technoline
- Termostaatti Drayton Erie
- Termostaatti Nefit
- Termostaatti Fantini Cosmi
- Termostaatti Saunier Duval
- Termostaatti Tado
- Termostaatti Rademacher
- Termostaatti Econo-Heat
Viimeisimmät Termostaatti Käyttöohjeet
10 Joulukuuta 2024
10 Joulukuuta 2024
10 Joulukuuta 2024
7 Joulukuuta 2024
6 Joulukuuta 2024
4 Joulukuuta 2024
4 Joulukuuta 2024
26 Lokakuuta 2024
26 Lokakuuta 2024
26 Lokakuuta 2024