Whirlpool MSA 3G3F IX Käyttöohje

Whirlpool Uuni MSA 3G3F IX

Lue alta 📖 käyttöohje suomeksi merkille Whirlpool MSA 3G3F IX (14 sivua) kategoriassa Uuni. Tämä opas oli hyödyllinen 3 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/14
www.whirlpool.eu/register
Health & Safety, & Use Care and Installation Guides
Consignes d’installation, utilisation et sécurité,
Guía de salud seguridad instalación y , uso cuidado y y de
Guia de Saúde e Seguraa, Utilização e
Manutenção e Instalação
      
SAFETY INSTRUCTIONS IMPORTANT TO BE READ AND OBSERVED
These instructions are valid if the country
symbol appears on the appliance. If the symbol
does not appear on the appliance, please refer
to the technical instructions which will provide
the necessary instructions concerning
modification of the appliance to the conditions
of use of the country.
CAUTION : Use of the gas cooking appliance
results in the production of heat, moisture and
products of combustion in the room in which it
is installed. Ensure that the kitchen is well
ventilated, especially when the appliance is in
use: keep natural ventilation holes open or install
a mechanical ventilation device (mechanical
extractor hood). Prolonged intensive use of the
appliance may call for additional ventilation,
such as opening a window, or more effective
ventilation, for example increasing the level of
mechanical ventilation (if possible).
Failure to follow the information in this
manual exactly may cause a fire or explosion,
resulting in property damage or personal injury.
Before using the appliance, read these safety
instructions. Keep them nearby for future
reference.
These instructions and the appliance itself
provide important safety warnings, to be
observed at all times. The manufacturer declines
any liability for failure to observe these safety
instructions, for inappropriate use of the
appliance or incorrect setting of controls.
Very young children (0-3 years) should be
kept away from the appliance. Young children
(3-8 years) should be kept away from the
appliance unless continuously supervised.
Children from 8 years old and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and knowledge
can use this appliance only if they are supervised
or have been given instructions on safe use and
understand the hazards involved. Children must
not play with the appliance. Cleaning and user
maintenance must not be carried out by children
without supervision.
WARNING: The appliance and its accessible
parts become hot during use. Care should be
taken to avoid touching heating elements.
Children less than 8 years of age must be kept
away unless continuously supervised.
Never leave the appliance unattended during
food drying. If the appliance is suitable for probe
usage, only use a temperature probe
recommended for this oven - risk of fire.
Keep clothes or other flammable materials
away from the appliance, until all the components
have cooled down completely - risk of fire.
Always be vigilant when cooking foods rich in
fat, oil or when adding alcoholic beverages - risk
of re. Use oven gloves to remove pans and
accessories. At the end of cooking, open the
door with caution, allowing hot air or steam to
escape gradually before accessing the cavity -
risk of burns. Do not obstruct hot air vents at the
front of the oven - risk of fire.
Exercise caution when the oven door is in the
open or down position, to avoid hitting the door.
When you place the rack inside, make sure that
the stop is directed upwards and in the back of
the cavity.
The device shall not be operated for more 15 s. If
after 15s the burner has not lit, stop operating
the device and open the compartment door
and/or wait at least 1 min before attempting a
further ignition of the burner.
PERMITTED USE
CAUTION: The appliance is not intended to be
operated by means of an external switching
device, such as a timer, or separate remote
controlled system.
This appliance is intended to be used in
household and similar applications such as: staff
kitchen areas in shops, offices and other working
environments; farm houses; by clients in hotels,
motels, bed & breakfast and other residential
environments.
No other use is permitted (e. g. heating
rooms).
This appliance is not for professional use.
Do not use the appliance outdoors.
Do not store explosive or ammable
substances (e. g. gasoline or aerosol cans) inside
or near the appliance - risk of fire.
INSTALLATION
The appliance must be handled and installed
by two or more persons - risk of injury. Use
protective gloves to unpack and install - risk of
cuts.
The electrical and gas connections must
comply with local regulations.
Installation, including water supply (if any),
EN
electrical connections and repairs must be
carried out by a qualified technician. Do not
repair or replace any part of the appliance unless
specifically stated in the user manual. Keep
children away from the installation site. After un
packing the appliance, make sure that it has not
been damaged during transport. In the event of
problems, contact the dealer or your nearest
After-sales Service. Once installed, packaging
waste (plastic, styrofoam parts etc.) must be
stored out of reach of children - risk of suffocation.
The appliance must be disconnected from the
power supply before any installation operation
- risk of electric shock. During installation, make
sure the appliance does not damage the power
cable - risk of fire or electrical shock. Only activate
the appliance when the installation has been
completed.
WARNING : Modification of the appliance and
its method of installation are essential in order to
use the appliance safely and correctly in all the
additional countries.
Use pressure regulators suitable for the gas
pressure indicated in the instructions.
The room must be equipped with an air
extraction system that expels any combustion
fumes.
The room must also allow proper air
circulation, as air is needed for combustion to
occur normally. The ow of air must not be less
than 2 m³/h per kW of installed power.
The air circulation system may take air directly
from the outside by means of a pipe with an
inner cross section of at least 100 cm²; the
opening mustnot be susceptible to blockages.
The system can also provide the air needed
for combustion indirectly, i. e. from adjacent
rooms fitted with air circulation tubes as
described above. However, these rooms must
not be communal rooms, bedrooms or rooms
that may present a fire hazard.
Liquid petroleum gas sinks to the floor as it is
heavier than air. Therefore, rooms containing
LPG cylinders must also be equipped with vents
to allow gas to escape in the event of a leak. This
means LPG cylinders, whether partially or
completely full, must not be installed or stored
in rooms or storage areas that are below ground
level (cellars, etc.). It is advisable to keep only the
cylinder being used in the room, positioned so
that it is not subject to heat produced by external
sources (ovens, replaces, stoves, etc.) which
could raise the temperature of the cylinder
above 50°C.
Should you find it difficult to turn the knobs for the
burner, please contact the After-sales Service, who can
replace of the burner tap if found to be faulty.
The openings use for the ventilation and dispersion of
heat must never be covered.
Carry out all cabinet cutting works before
fitting the appliance in the furniture and remove
all wood chips and sawdust.
Do not remove the appliance from its polystyrene
foam base until the time of installation.
After installation, the bottom of the appliance
must no longer be accessible - risk of burn.
Connection with rigid pipe (copper or steel):
If the gas pressure is different from the
recommended pressure, a suitable pressure
regulator must be tted to the inlet pipe in
accordance with the current National
Regulations. Use an appropriate cabinet to
ensure that the appliance operates properly: to
install the oven under the counter (see diagram)
or in a kitchen unit, the cabinet must have the
dimensions as the picture.
To ensure adequate ventilation, the back panel
of the cabinet must be removed. It is advisable
to install the oven so that it rests on two strips of
wood, or on a completely at surface with an
opening of at least 45 x 560 mm as the picture.
Do not install the appliance behind a
decorative door - risk of fire.
If the appliance is installed under the worktop,
do not obstruct the minimum gap between the
worktop and the upper edge of the oven - risk of
burns.
GAS CONNECTION
WARNING : Prior to installation, ensure that
the local distribution conditions (type of gas and
gas pressure) and the configuration of the
appliance are compatible.
Check that the pressure of the gas supply is
consistent with the values indicated in Table 1
(“Burner and nozzle specifications”).
WARNING : The configuration conditions of this
appliance are stated on the label (or data plate).
WARNING : This appliance is not connected to
a combustion products evacuation device. It
must be installed and connected in accordance
with current installation regulations. Particular
attention must be paid to the relevant
requirements regarding ventilation.
If the appliance is connected to liquid gas, the
regulation screw must be fastned as tightly as
possible.

Tuotetiedot

Merkki: Whirlpool
Kategoria: Uuni
Malli: MSA 3G3F IX

Tarvitsetko apua?

Jos tarvitset apua merkille Whirlpool MSA 3G3F IX esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Uuni Whirlpool Käyttöohjeet

Uuni Käyttöohjeet

Viimeisimmät Uuni Käyttöohjeet