INSTALLATION INSTRUCTIONS FOR PART TRIGGER
METRA. The World’s best kits.™ metraonline.com1-800-221-0932 © COPYRIGHT 2004-2013 METRA ELECTRONICS CORPORATION
REV. 12/30/2013 INSTTRIGGER
CAUTION: Metra recommends disconnecting the
negative battery terminal before beginning any
installation. All accessories, switches, and especially
air bag indicator lights must be plugged in before
reconnecting the battery or cycling the ignition.
NOTE: Refer to the instructions included with the
aftermarket radio.
The “Trigger is a universal module the provides 14 different preset functions that are
activated from a positive or negative trigger. In addition, to the preset features, the
Trigger has 8 custom modes with customizable settings that allows the installer to
utilize their imagination.
KIT FEATURES
• Cutting tool • Crimping tool • Tape • Connectors
(example: butt-connectors, bell caps, etc.)
TOOLS REQUIREd
APPLICATIONS
N/A - Universal module TRIGGER
INTERFACE COMPONENTS
TRIGGER
Table of Contents
General
Pin diagram ....................................................................................................... 3
Mode descriptions and wiring instructions .....................................................3-8
Mode 1: Retained accessory power .................................................................... 4
Mode 2: Delayed amp turn-on ............................................................................ 4
Mode 3: Low voltage turn-on ............................................................................. 4
Mode 4: Latched outputs .................................................................................... 4
Mode 5: GMLAN aftermarket amp turn-on .......................................................... 5
Mode 6: Active edge pulse generator .................................................................. 5
Mode 7: Turn-off delay ....................................................................................... 6
Mode 8: Double pulse latch ................................................................................ 6
Mode 9: Double pulse to one-second output ....................................................... 6
Mode 10: Theft detection/closed loop trigger ...................................................... 7
Mode 11: Channel expander ............................................................................... 7
Mode 12: Simple data detector (amp turn-on signal from data) ................................ 7
Mode 13: Long delayed turn-off (for headlights) .................................................... 8
Mode 14: Dome light delay ................................................................................. 8
Mode 15: Custom program ................................................................................. 8
Custom program modes
Custom Mode 1: Channel expander, latched ....................................................8-9
Custom Mode 2: Channel expander, pulsed ........................................................ 9
Custom Mode 3: Delayed turn-off ..................................................................... 10
Custom Mode 4: Delayed turn-on ..................................................................... 10
Custom Mode 5: Delayed three-output delay/pulse width, edge driven
(for use with linear actuators) ..........................................................................10-11
Custom Mode 6: Generic three-output delay/pulse width, level driven (validity) .... 11
Custom Mode 7: Square wave-generator (sounds horns, blinks lights) .............11-12
Custom Mode 8: Multiple pulse generator ........................................................ 12
TRIGGER
Pin diagram
Note:
Pin-1 needs to be attached to ground and pin-11 needs to be attached to 12
volt constant on all configurations listed below.
Metra recommends using a single pulse double throw relay in every application
(Metra part # E-123).
Default: E-brake emulator
Description: Emulates an e-brake signal for use in RV’s, off road vehicles,
and exhibition vehicles.
Connections:
Interface wiring To
Pin-6 (Green) Aftermarket radios parking brake input
Pin-7 (Red) Aftermarket radios parking brake input
Pin-8 (Blue) Foot brake of radio
Pin-9 (Brown) Vehicles accessory or ignition
Mode descriptions and
wiring instructions
Pin-1: Black (chassis ground)
Pin-2: Purple (configuration input)
Pin-3: White (configuration input)
Pin-4: Pink (configuration input)
Pin-5: Orange (configuration input)
Pin-6: Green ((-) output 500mA max)
Pin-7: Red ((-) output 500mA max)
Pin-8: Blue ((+) output 2 amp max)
Pin-9: Brown (+ 0.8- 16v input trigger)
Pin-10: Gray (- input trigger)
Pin-11: Yellow (12 volt constant/switched)
TRIGGER
(Mode descriptions and wiring instructions continued on next page)

Tuotetiedot

Merkki: AXESS
Kategoria: Ei luokiteltu
Malli: TRIGGER

Tarvitsetko apua?

Jos tarvitset apua merkille AXESS TRIGGER esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Ei luokiteltu AXESS Käyttöohjeet

AXESS

AXESS AXDSPX-BM1 Käyttöohje

25 Lokakuuta 2024
AXESS

AXESS AXDIS-BW122 Käyttöohje

15 Lokakuuta 2024
AXESS

AXESS 99-3303 Käyttöohje

15 Lokakuuta 2024
AXESS

AXESS AXBT-MZ2 Käyttöohje

15 Lokakuuta 2024
AXESS

AXESS AX-ALOC618 Käyttöohje

15 Lokakuuta 2024
AXESS

AXESS ANC-GMH3 Käyttöohje

15 Lokakuuta 2024
AXESS

AXESS ANC-GMH2 Käyttöohje

15 Lokakuuta 2024
AXESS

AXESS ANC-CHH2 Käyttöohje

15 Lokakuuta 2024
AXESS

AXESS AX-AB-CH3 Käyttöohje

15 Lokakuuta 2024
AXESS

AXESS AX-AB-CH4 Käyttöohje

15 Lokakuuta 2024

Ei luokiteltu Käyttöohjeet

Viimeisimmät Ei luokiteltu Käyttöohjeet