Broan 770RLTK Käyttöohje
Lue alta 📖 käyttöohje suomeksi merkille Broan 770RLTK (12 sivua) kategoriassa Tuuletin. Tämä opas oli hyödyllinen 2 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä
Sivu 1/12

MODELS 770RLTK, 770RLTKC, 770RNLTK
Register this product at www.broan.com/register or www.nutone.com/reg-
ister. For Warranty Statement, or to order Service Parts: go to www.broan.
com and type the Model in the “Model Search” field at the top of the page.
Broan, 926 W. State Street, Hartford, WI 53027 800-558-1711 or
888-336-3948
1
Ventilation Fan with Decorative Light
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PER-
SONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from be-
ing switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not install in a bathtub or shower enclosure.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently protected.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
2. This product is designed for installation in FLAT CEILINGS ONLY. Do
not mount this product in a wall.
3. The light fixture assembly must be mounted to the fan housing assembly
included with this product. Do not mount the light fixture assembly to
a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
5. Please read specification label on product for further information and
requirements.
TYPICAL INSTALLATIONS
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
HOUSING
2 x 4
CEILING
JOIST or
TRUSS
MOUNTING
TABS
POWER CABLE ADDITIONAL
FRAMING
2 x 4
CEILING
JOIST or
TRUSS
CEILING
MATERIAL
GRILLE
PAN
GLASS
LIGHT SHADE
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
HOUSING MOUNTED
TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
* Additional framing must be a 2x6 (minimum height).
*
*
SUSPENDED CEILINGS
Housing hung with wires -
3-point mount.
PLAN THE INSTALLATION
ROOF CAP*
(with built-in
damper)
WALL CAP*
(with built-in
damper)
4-IN. ROUND
ELBOWS*
4-IN. ROUND
DUCT*
FAN
HOUSING
Seal gaps
around
housing.
Seal duct
joints with
tape.
Keep duct
runs short.
INSULATION
(Place around and
over fan housing.)
POWER
CABLE*
*Purchase
separately.
OR
INSTALL THE HOUSING
1. Choose the location for your fan in the ceiling. For best possible
performance, use the shortest possible duct run and a minimum
number of elbows.
2. Position mounting brackets
against joist so that bottom
edge of housing will be flush
with finished ceiling.
Additional positioning
feature for 5/8”, 1”, &
1-1/4” thick ceiling material:
Holes in corners of housing
are labeled with various ceiling
material thicknesses. Position
housing so bottom edge of joist is visible through a matched
set of holes. The housing is now in the proper position for that
ceiling material thickness.
Additional positioning feature for 1/2” thick ceiling material:
Bend two tabs, on side of housing,
900 outward. Lift housing until
tabs contact underside of joist.
Mark the keyhole slot on both mounting brackets.
New Construction
5/8
1
1-1/4
TAB
HOLES
BOTTOM EDGE OF JOIST
- PLEASE NOTE -
THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 6
JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTALLATION, MOUNT
THE VENTILATOR TO THE ADDITIONAL FRAMING IN THE SAME MAN-
NER. (Additional framing must be a 2x6 (minimum height).

2
3. Set housing aside and
drive nails partially
into joist at the top of
both keyhole marks.
4. Hang housing from
nails and pound nails
tight. To ensure a
noise-free mount,
pound another nail
through the top hole of
each mounting tab.
Existing Construction
2. In attic, position mounting brackets against joist. Trace outline
of housing on ceiling material.
1. Choose the location for your fan/light in the ceiling. For best
possible performance, use the shortest possible duct run and a
minimum number of elbows.
3. Set housing aside and cut ceiling opening slightly larger than
marked.
4. Place housing in
opening so that its
bottom edge is flush
with finished ceiling.
Nail to joist through
keyhole on both
sides. To ensure a
noise-free installation,
drive another nail
through the top hole
of each mounting
bracket.
5. Additional mounting holes are provided for installations where
access from above is inconvenient or not possible. Nail or screw
housing directly to joists or framing.
ADDITIONAL
MOUNTING
HOLES
New Construction
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK RED
GROUND
(bare)
WIRING
PLATE
120 VAC
LINE IN
BLUE BLACK
RECEPTACLE
(FAN)
WHITE
RECEPTACLE
(LIGHT)
CONNECT THE WIRING
1. Wire unit following diagram above. Run electrical cable as direct
as possible to unit. Do not allow cable to touch sides or top of
unit after installation is complete.
INSTALL THE DUCTWORK
FLUSH
NOTE: The duct connector has a
counter-balanced damper flap. The
flap will be “open” approx. 1” when
duct connector is attached to hous-
ing. This design permits insulation
to be in direct contact with fan/
light housing per UL (Underwrit-
ers Laboratories) standards. The
slightest backdraft, however, will
close the damper flap, preventing air
from entering unit or finished space.
1. Snap the damper/duct connector onto housing. Make sure that
tabs on the connector lock into slots in housing. Top of damper/
duct connector should be flush with top of housing.
NOTE: Make sure damper flap is in place inside of duct connector.
If it is not: Squeeze top and bottom of connector to
snap flap
back into place.
2. Connect 4” round duct to damper/duct connector and extend
duct to outside through a roof or wall cap. Check damper to make
sure that it opens freely. Tape all duct connections to make them
secure and air tight.

3
1. Locate the grille
pan over the
fan housing and
connect the wiring
harness plug into
white receptacle in
the fan housing.
2. Insert rod through
washer and
through center
hole of grille pan.
3. Thread rod onto grille
screw in housing,
until pan is tight
against ceiling. Do not
overtighten mounting
rod.
4. Install bulb. Use 60-watt
(maximum), E26 base
bulb.
5. Place rim of glass shade
into opening of two
stationary hooks. Pull
out the spring-loaded
hook and latch hook over
rim of glass shade.
6. Restore electrical power and check operation of the unit.
GRILLE
PAN
GRILLE
SCREW
WASHER
ROD
GLASS SHADE
MOTOR
MOUNTING
PLATE
GLASS
SHADE
GRILLE
PAN
ROD
WASHER
60 WATT MAX.
E26 BASE BULB
STATIONARY
HOOKS
SPRING-LOADED
HOOK
USE AND CARE
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND LOCK OUT
SERVICE PANEL BEFORE CLEANING OR SERVICING THIS UNIT.
BULB REPLACEMENT
Remove glass shade. Replace bulbs as required. Replace glass shade.
Use 60-watt (maximum), E26 type, bulb .or energy efficient equivalent
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble motor.
CLEANING
TO CLEAN GLASS SHADE AND GRILLE PAN:
Remove glass shade. Shade can be wiped clean with a mild detergent
solution or glass cleaner and dried with a soft cloth. Remove bulb. Grille
pan may be gently vacuumed and wiped clean with a soft cloth. Never
use abrasive cloth, steel wool pads or scouring powders on glass shade
or grille pan. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IM-
MERSED IN WATER.
TO CLEAN FAN ASSEMBLY:
Remove grille pan and unplug fan assembly (black receptacle). Gently
vacuum fan, motor and interior of housing. METAL AND ELECTRICAL
PARTS SHOULD NEVER BE IMMERSED IN WATER.
1102078B
ATTACH THE GRILLE PAN
AND GLASS SHADE
Tuotetiedot
Merkki: | Broan |
Kategoria: | Tuuletin |
Malli: | 770RLTK |
Tarvitsetko apua?
Jos tarvitset apua merkille Broan 770RLTK esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Tuuletin Broan Käyttöohjeet

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025
Tuuletin Käyttöohjeet
- Tuuletin NewAir
- Tuuletin Bosch
- Tuuletin BEKO
- Tuuletin Exquisit
- Tuuletin Café
- Tuuletin DeWalt
- Tuuletin Philips
- Tuuletin Thermex
- Tuuletin Hotpoint
- Tuuletin Cecotec
- Tuuletin Enermax
- Tuuletin Comfee
- Tuuletin Imarflex
- Tuuletin Kogan
- Tuuletin Solis
- Tuuletin Create
- Tuuletin Kichler
- Tuuletin Midea
- Tuuletin BlueBuilt
- Tuuletin Orbegozo
- Tuuletin NEO Tools
- Tuuletin Gemini
- Tuuletin Koenic
- Tuuletin Panasonic
- Tuuletin Lian Li
- Tuuletin Westinghouse
- Tuuletin Sencor
- Tuuletin Canarm
- Tuuletin Orava
- Tuuletin Mistral
- Tuuletin Khind
- Tuuletin EMOS
- Tuuletin Clean Air Optima
- Tuuletin Taurus
- Tuuletin Dimplex
- Tuuletin Ryobi
- Tuuletin Breville
- Tuuletin Bimar
- Tuuletin Sharkoon
- Tuuletin Gamdias
- Tuuletin Concept
- Tuuletin Livoo
- Tuuletin Brandson
- Tuuletin CSL
- Tuuletin Ausclimate
- Tuuletin Nevir
- Tuuletin Infiniton
- Tuuletin Ufesa
- Tuuletin Milwaukee
- Tuuletin Omega Altise
- Tuuletin Scarlett
- Tuuletin Daikin
- Tuuletin Rowenta
- Tuuletin Be Cool
- Tuuletin Thermaltake
- Tuuletin Master
- Tuuletin V-Tac
- Tuuletin Termozeta
- Tuuletin Hunter
- Tuuletin Ebm-papst
- Tuuletin DeepCool
- Tuuletin Nedis
- Tuuletin Magmatic
- Tuuletin Eldom
- Tuuletin Elba
- Tuuletin Vonroc
- Tuuletin ECG
- Tuuletin Renkforce
- Tuuletin Modern Fan Co.
- Tuuletin Quorum International
- Tuuletin Bestron
- Tuuletin Signature
- Tuuletin Soler And Palau
- Tuuletin Bionaire
- Tuuletin Toshiba
- Tuuletin S&P
- Tuuletin Eurolite
- Tuuletin Mystery
- Tuuletin Middle Atlantic
- Tuuletin Duracraft
- Tuuletin Mellerware
- Tuuletin Home Electric
- Tuuletin Tefal
- Tuuletin Perfect Aire
- Tuuletin Svan
- Tuuletin LifeSmart
- Tuuletin Izzy
- Tuuletin Honeywell
- Tuuletin Fantini Cosmi
- Tuuletin Lasko
- Tuuletin Be Quiet!
- Tuuletin Casablanca
- Tuuletin Biltema
- Tuuletin Emerio
- Tuuletin Prime3
- Tuuletin Yamazen
- Tuuletin KDK
- Tuuletin Vornado
- Tuuletin Keystone
- Tuuletin Savio
- Tuuletin Ardes
- Tuuletin Proline
- Tuuletin Soler & Palau
- Tuuletin Aspes
- Tuuletin Sôlt
- Tuuletin Unold
- Tuuletin Tornado
- Tuuletin Windmill
- Tuuletin Premium
- Tuuletin ActiveJet
- Tuuletin Haus & Luft
- Tuuletin Ideal
- Tuuletin Baxi
- Tuuletin Aerian
- Tuuletin Gutfels
- Tuuletin Grunkel
- Tuuletin Duux
- Tuuletin Proficare
- Tuuletin Listo
- Tuuletin InLine
- Tuuletin Magnavox
- Tuuletin SHE
- Tuuletin Air&Me
- Tuuletin EWT
- Tuuletin Click
- Tuuletin Bestherm
- Tuuletin ThreeSixty
- Tuuletin Valueline
- Tuuletin PAX
Viimeisimmät Tuuletin Käyttöohjeet

2 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

31 Maaliskuuta 2025

30 Maaliskuuta 2025

30 Maaliskuuta 2025

30 Maaliskuuta 2025