Important Safety Information .................3
Installation Instructions ........................... 4
Controls ..........................................................8
Controls and Operating Functions ..... 9
On Board Diagnostics .............................. 11
Fault Codes ................................................. 12
Wiring Diagram ......................................... 13
Testing the Thermostat ..........................14
Troubleshooting ........................................ 16
Limited Warranty ...................................... 17
Consumer Support ................................... 18
49-5000400 Rev. 5
05-21 GEA
THERMOSTAT
OWNER’S MANUAL
& INSTALLATION
INSTRUCTIONS
RARWT_ _ (Single Zone Smart T.Stat)
RARMC_ _ (Standard Ceiling Control)
RAREC3A (Standard Ceiling Control)
RAREC2A (Direct Wire or Smart T.Stat)
RAREC1A (RV-C or Smart T.Stat Control)
Write the model and serial numbers
here:
Model # ____________________
Serial # ____________________
You can find them on a label on the
thermostat.
GE is a trademark of the General Electric Company.
Manufactured under trademark license.
Single Zone RV
249-5000400 Rev. 5
THANK YOU FOR MAKING GE
APPLIANCES A PART OF YOUR RV.
Whether you grew up with GE Appliances, or this is
your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and
design that goes into every GE Appliances product,
and we think you will too. Among other things,
registration of your appliance ensures that we can
deliver important product information and warranty
details when you need them.
49-5000400 Rev. 5 3
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING FIRE AND SHOCK HAZARD
Ŷ
Always turn off power at the main power supply before
installing, cleaning or removing the thermostat.
Ŷ
Do not use on voltages over 12 VDC. Higher voltages will
damage the thermostat and could cause shock or fire hazards.
Ŷ
All wiring must conform to local and national electrical and
building codes.
Ŷ
Use this thermostat only as described in this manual.
Specications
Electrical Rating:
12 VDC (Operating Range from 10.5 VDC - 15.5 VDC)
Wall Thermostat Terminations:
0V (GND), Signal (COMMS), +12VDC
Recommended Wire Sizes:
Operating Ranges Setpoint Ranges
Cooling 60ºF–115ºF 15ºC–46ºC 60ºF–85ºF 15ºC–30ºC
Heat-Pump 25ºF–85ºF -4ºC–30ºC 40ºF–85ºF 5ºC–30ºC
Furnace See Owner’s Manual 40ºF–85ºF 5ºC–30ºC
CIRCUIT WIRE GAUGE Copper Wire Type
115 VAC Control Power 12awg SOLID
12 VDC Control Power 14awg~18awg STRANDED
12 VDC Thermostat 18awg~22awg SOLID
COMMUNICATION CONNECTIONS
Ceiling
Control
GEA Smart
Wall
Thermostat
(RARWT_ _)
5 Wire
Direct
Connect
RV-C
Network
RV-C Room
Sensor
Compatible
(RARES1_)
Aux.
Furnace
Connection
Auto Gen
Start
Connection
RARMC2A_ X X
RAREC3A_ X X
RAREC2A_ X X X X
RAREC1A_ X X X X X

Tuotetiedot

Merkki: Café
Kategoria: Ei luokiteltu
Malli: RARWT2W

Tarvitsetko apua?

Jos tarvitset apua merkille Café RARWT2W esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Ei luokiteltu Café Käyttöohjeet

Café

Café RARWT2W Käyttöohje

5 Tammikuuta 2025
Café

Café CXADTH1PMBT Käyttöohje

10 Joulukuuta 2024
Café

Café CXLB3H3PMBT Käyttöohje

10 Joulukuuta 2024
Café

Café CX153P4MWM Käyttöohje

10 Joulukuuta 2024
Café

Café CXWS0H0PMBT Käyttöohje

10 Joulukuuta 2024
Café

Café CXWD0H0PMBT Käyttöohje

10 Joulukuuta 2024
Café

Café CX152P4MWM Käyttöohje

10 Joulukuuta 2024

Ei luokiteltu Käyttöohjeet

Viimeisimmät Ei luokiteltu Käyttöohjeet