D O M E C A M E R A
I N S T R U C T I O N M A N U A L
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and maintenance
(servicing) instructions in the literature
accompanying the appliance.
CAUTION
CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning flash with arrowhead symbol, within
an equilateral triangle, is intended to alert the user
to the presence of uninsulated "dangerous
voltage" within the product's enclosure that may
be of sufficient magnitude to constitute a risk of
electric shock to persons.
T N D 4 0 0 4
CAUTION
· Do not use any power supply other than
specified.
WARNING
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE.
* The CAUTION label is attached on the back
of camera.
INFORMATION
This equipment has been tested and
found to comply with the limits for Class A
digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to
provide reasonable protection against
harmful interference when the equipment
is operated in a commercial environment.
This equipment generates, use, and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a
residential area is likely to cause harmful
interference in which case the user will be
required to correct the interference at his
own expense.
USER-INSTALLER CAUTION: Your
authority to operate this FCC verified
equipment could be voided if you make
changes or modifications not expressly
approved by the party responsible for
compliance to Part of the FCC Rules.
- 1 -
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings, install in accordance with the manufacture's instructions.
8. Do not install near heat sources such a radiators, heat registers, stoves or other apparatus (including
amplifiers) that produce heat.
9. Only use attachment/accessories specified by the manufacturer.
10. Unplug this apparatus during lighting storms or when unused for long periods of time.
11. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged
in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have
been fallen onto the apparatus, the apparatus has been exposed to rain or moisture, does not operate
normally, or has been dropped.
- 2 -
1. Appearance view
2. Specifications
106 (4.2)
SR53 (2.1)
SR56 (2.2)
Unit : mm (inch)
Model
Power source
Power consumption
Pick-up device
Effective picture element
Scanning area
Scanning system
Scanning frequency
Sync. system
Resolution
S/N ratio
Standard illumination
AGC
Sens-up
White balance
Backlight control (BLC)
Iris level adjustment
VIDEO OUT terminal
Lens
Angle of view
Iris
Appearance color
Dimensions
Weight
Ambient temperature
Ambient humidity
TND4004
DC 12V (DC 11V-35V) or AC 24V (AC 15V-27V) 60Hz ± 0.5Hz
Approx. 3.5W
1/3" Color interline-transfer CCD
768 (H) X 494 (V)
4.88mm (H) X 3.66mm (V)
2:1 interlaced
LL : 15.75kHz (H), 60Hz (V) / INT : 15.734kHz (H), 59.94Hz (V)
Line-Lock/Internal (Factory-set at Line-Lock)
470TV lines (H), 350TV lines (V)
More than 48dB
150 lx (F1.4 under incandescent lamp)
Built-in
Provided (Factory-set at OFF)
ATW/AWC/manual/Preset (Factory-set at ATW)
Provided (Factory-set at OFF)
Provided (volume adjustment)
VBS 1V (p-p) 75
F 1.4, f = 2.8 ~ 6mm
Horizontal : 47° (TELE) ~ 96° (WIDE)
Vertical : 36° (TELE) ~ 72° (WIDE)
Auto
Main body : White
Cover : Black
Diameter : 116mm (4.6") Height : 106mm (4.2") without protruded part
0.5 kg (1.1 lbs)
-10°C ~ +50°C (14°F~122°F)
30% ~ 90%
Note : Weight and dimensions are approximate.
Design and specifications are subject to change without prior notice.

Tuotetiedot

Merkki: Elmo
Kategoria: Ei luokiteltu
Malli: TND4004

Tarvitsetko apua?

Jos tarvitset apua merkille Elmo TND4004 esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Ei luokiteltu Elmo Käyttöohjeet

Elmo

Elmo P30 Käyttöohje

16 Lokakuuta 2024
Elmo

Elmo EV-200 Käyttöohje

16 Lokakuuta 2024
Elmo

Elmo PentaClass A Käyttöohje

16 Lokakuuta 2024
Elmo

Elmo HV-C1000XG Käyttöohje

16 Lokakuuta 2024
Elmo

Elmo TND4004 Käyttöohje

16 Lokakuuta 2024
Elmo

Elmo ESD-CC1 Käyttöohje

16 Lokakuuta 2024
Elmo

Elmo Chroma Quad4 Käyttöohje

16 Lokakuuta 2024
Elmo

Elmo EV-368 Käyttöohje

16 Lokakuuta 2024

Ei luokiteltu Käyttöohjeet

Viimeisimmät Ei luokiteltu Käyttöohjeet