Akun laturi
LiFeKinnex
Lue alta 📖 käyttöohje suomeksi merkille Ergotron LiFeKinnex (3 sivua) kategoriassa Akun laturi. Tämä opas oli hyödyllinen 3 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä
Sivu 1/3

1 of 18
888-83-081-G-00 rev. B • 03/19
www.ergotron.com | USA: 1-800-888-8458 | Europe: +31 (0)33-45 45 600 | China: 400-120-3051 | Japan: japansupport@ergotron.com
Please review this manual before installing your equipment to learn how to use this product safely.
The LiFeKinnex Charger is designed to charge up to 4 LiFeKinnex Batteries simultaneously. (Battery Model FBP-1164, Part Number 916-333-00)
The charger can be placed on a desk or mounted fl ush on the wall.
This product is certifi ed according to IEC/EN 60601-1, as class I equipment.
AC input: 100-240V~ 50/60-Hz. Max amps: 4.8 - 2.1A.
Manufactured for Ergotron by Green Cubes Technology www.greencubestech.com
Patents Ergotron.com/patents
Batteries Sold Separately.
For the latest User Installation Guide please visit: www.ergotron.com
English, Español, Français, Deutsch, Nederlands, Italiano, Svenska, 日本語, 汉语
User's Guide
English
4-Bay Charger
Wall MountedDesk Top

2 of 18
888-83-081-G-00 rev. B • 03/19
Equipment Electrical Safety
WARNING: Failure to observe the following Electrical Safety notices can result in fi re or death by electric shock.
Electrical cables can be hazardous. Misuse can result in fi re or death by electrical shock.
• Inspect power cables thoroughly before each use.
• Do not use cables that are damaged.
• Insert the plug completely into the outlet.
• Grasp the plug to remove from the outlet.
• Do not unplug by pulling on the cable.
• Do not use excessive force to make connections.
• Do not plug the cable into an extension cable.
• Do not remove, bend or modify any metal prongs or pins of cable.
• Do not drive, drag or place objects over the cable.
• Do not walk on the cable.
• Avoid overheating.
• Do not run cable through doorways, holes in ceilings, walls or fl oors.
Keep away from water.
• Do not use it when wet.
• Do not place in close proximity to fl ammable liquids or gases.
WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is
necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
WARNING: Use of accessories, transducers and cables other than those specifi ed or provided by the manufacturer of this equipment could result in increased
electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
CAUTION: The power disconnect for this equipment is the AC power cable.
The socket outlet should be easily accessible and should be installed near the equipment.
Do not use this unit outdoors.
Never unplug this product from the outlet when your hands are wet.
Any modifi cations made to this device that are not approved, may void the authority granted to the user by the FCC to operate this equipment.
Ensure the product is connected to an outlet having the same confi guration as the plug. No adapter should be used with this product.
Ergotron does not accept any liability for damage if the unit is misused, incorrectly operated or inadequately repaired. Under these circumstances the warranty will be
void.
CAUTION: To avoid the potential to pinch cables it is important to
follow the cable routing instructions in this manual. Failure to follow
these instructions may result in equipment damage or personal injury.
DANGER! Electrical cables can be hazardous.
Misuse can result in fi re or death by electrical shock.
These symbols alert users of a safety
condition that demands attention. All users
should be able to recognize and understand
the signifi cance of the following Safety
Hazards if encountered on the product or
within the documentation. Children who
are not able to recognize and respond
appropriately to Safety Alerts should not use
this product without adult supervision!
Hazard Symbols Review
Safety Symbol Signal Word Level of Hazard
INSTRUCTIONS Refer to instruction manual/booklet.
Follow instructions for use.
CAUTION
A CAUTION indicates either potential damage to
hardware or loss of data and tells you how to avoid the
problem.
WARNING A WARNING indicates either potential for property
damage, personal injury, or death.
DANGER A DANGER indicates a hazardous situation that, if not
avoided, will result in death or serious injury.

3 of 18
888-83-081-G-00 rev. B • 03/19
Do not attempt to connect the charger in serial or parallel with any other charger. This system was not designed to serve this purpose.
This Charger shall be installed by qualifi ed personnel only. The system shall be always installed in the vertical direction as shown in the picture on cover page.
WARNING: DO NOT charge battery with any other charger.
WARNING: Battery contains magnets. Magnets may be harmful to persons with implanted medical devices. Keep battery at least 6" (152 mm) away from any
implanted medical devices.
WARNING: Keep battery and charger cool or at room temperature
Operating Temperature: 10°C to 40°C (50°F to 113°F)
Storage Temperature: -20°C to 45°C (-4°F to 113°F)
WARNING: Never attempt to open or service the battery.
WARNING: Never attempt to short circuit the battery or the charger intentionally.
WARNING: DO NOT drop, puncture or crush battery or expose to water.
WARNING: DO NOT dispose battery in fi re in any circumstances. Keep battery pack away from any hot source.
WARNING: DO NOT use battery if physical damage is evident.
To avoid risk of electric shock, do not expose electrical component to water, cleaning solution or other potentially corrosive liquids or substances.
To avoid risk of electric shock, this equipment must be connected to AC mains with protective earth.
WARNING: In rare case, if the charger and battery protection features fail, the battery may become overcharged and in some instances, it may become
extremely hot, possibly melting the plastics and releasing smoke.
If a battery begins to smoke or melts:
Unplug the charger, or if possible disconnect the battery from charger immediately.
Move the battery to a well-ventilated area.
Use a Carbon Dioxide, Dry Chemical, or appropriate foam fi re extinguisher to spray the hot battery. If a fi re extinguisher is not available, use copious amounts of
water, or cover the battery with sand. Exposure to vapor released from the battery is irritating to the eyes, skin, mucous membranes, and respiratory tract.
This may cause nausea, dizziness, and headache.
In case of direct contact to the battery's electrolyte:
Immediately fl ush eyes with water for at least 15 minutes.
Thoroughly rinse hands and other aff ected areas with water.
Promptly remove and wash any contaminated clothing.
In all cases, seek immediate medical attention!
Placement:
Do not expose the charger to direct sunlight or other heat source.
Ensure the operating environment is well ventilated to allow adequate dissipation of heat.
Ensure the charger's surrounding area is clean and free from moisture.
Do not put heavy objects on the charger.
AC Inlet power cords:
AC mains plug shall have the protective earth pin. By connecting the plug to the charger,
it shall have not more than 200mΩ to any part of the system metal case.
The connector shall be an IEC 60320 compliant C13 plug.
The power cords shall be IEC 60227 or HO5VV compliances.
Tuotetiedot
Merkki: | Ergotron |
Kategoria: | Akun laturi |
Malli: | LiFeKinnex |
Tarvitsetko apua?
Jos tarvitset apua merkille Ergotron LiFeKinnex esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Akun laturi Ergotron Käyttöohjeet

3 Huhtikuuta 2025
Akun laturi Käyttöohjeet
- Akun laturi DeWalt
- Akun laturi Hama
- Akun laturi Schwaiger
- Akun laturi IKEA
- Akun laturi StarTech.com
- Akun laturi APSystems
- Akun laturi Sony
- Akun laturi Nitecore
- Akun laturi Trust
- Akun laturi Husqvarna
- Akun laturi Voltcraft
- Akun laturi Panasonic
- Akun laturi Shure
- Akun laturi Growatt
- Akun laturi Deye
- Akun laturi Milwaukee
- Akun laturi Ansmann
- Akun laturi Anova
- Akun laturi Mophie
- Akun laturi Celly
- Akun laturi Dometic
- Akun laturi V7
- Akun laturi Jackery
- Akun laturi Bebob
- Akun laturi Ventev
- Akun laturi PDP
- Akun laturi Sungrow
- Akun laturi Vimar
- Akun laturi Mean Well
- Akun laturi Osram
- Akun laturi Savio
- Akun laturi Digipower
- Akun laturi EGO
- Akun laturi IDX
- Akun laturi Bolt
- Akun laturi Sandberg
- Akun laturi Cellular Line
- Akun laturi Alogic
- Akun laturi Watson
- Akun laturi Gp Batteries
- Akun laturi Apa
- Akun laturi Recom
Viimeisimmät Akun laturi Käyttöohjeet

3 Huhtikuuta 2025

30 Maaliskuuta 2025

29 Maaliskuuta 2025

10 Maaliskuuta 2025

20 Helmikuuta 2025

12 Helmikuuta 2025

8 Helmikuuta 2025

7 Helmikuuta 2025

7 Helmikuuta 2025

7 Helmikuuta 2025