Flir MR40 Käyttöohje

Lue alta 📖 käyttöohje suomeksi merkille Flir MR40 (6 sivua) kategoriassa Mittauslaitteet. Tämä opas oli hyödyllinen 2 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/6
User Manual
Pen Moisture
Meter
MODEL MR40
Introduction
Thank you for choosing the FLIR MR40 Pen Moisture Meter with high power
flashlight. The MR40 measures moisture content (MC) in wood, brick, con-
crete and other building materials and traces leakage inside walls, ceilings,
and floors.
Description
1. Electrode pins protective cap
2. Power/Display Hold button
3. Display Hold icon
4. Moisture Reading
5. Battery status icon
6. Pocket clip
7. Flashlight ON/OFF button
8. Battery compartment cap
9. Flashlight
Operation
CAUTION
Electrode pins are extremely sharp. Use protective cap when instrument is not in use.
1. Long press the Power button to switch MR40 ON/OFF. The LCD displays
two blinking dashes, % symbol, and battery status icon. The MR40 auto-
matically switches OFF after 3 minutes.
2. Remove the protective cap to expose the electrode pins.
3. Carefully push pins into material under test. Insert pins perpendicular to
wood’s fiber structure.
4. Take several readings in various locations for the best representation of
the moisture present.
5. Read the LCD as follows:
Low pitch single beep indicates moisture from 5 to 12%.
High pitch single beep indicates moisture from 13 to 60%.
High pitch rapid beeping indicates moisture > 60% ( displayed).OL
6. Short press the Power/Hold button to freeze a reading ( icon is dis-H
played). Press again to exit.
7. Long press the flashlight button to switch the light ON or OFF.
8. Replace the protective cap when finished.
#NAS100218; r. AD/97201/97216; en-US 1
Battery Check and Replacement
The displayed battery bar indicates battery status. When the battery indicator
has no bars and is flashing, replace the batteries. To replace batteries, twist
off the battery compartment end-cap and replace the two AAA batteries, ob-
serving correct polarity. Secure the compartment before use.
Do not dispose of used batteries or rechargeable batteries in house-
hold waste.
Specifications
Display LCD
Measurement type Electrical resistance
Range 5 to 60% MC (moisture content)
Accuracy
5 to 30% MC: ±2% of reading
30 to 60% MC: Reference only
Note: Displayed reading is for Group 9/Building Materials, including plywood, drywall, and
oriented strand board (OSB). For other materials, download the MR40 Material Conver-
sion Chart (publication MR40-AN01): http://flir.custhelp.com/app/account/fl_downloads
Resolution 1%
Electrode pins Integrated, replaceable
Auto Power OFF (APO) After three (3) minutes
Power supply 2 x 1.5 V AAA batteries
Battery status indicators Battery bar icon
Meter housing Impact-proof plastic
Dimensions 7.6 x 1.0 x 0.8 in. (192.8 x 26.1 x 31.2 mm)
Weight 2.8 oz. (80 g) with batteries
Limited 3–Year Warranty
This product is protected by FLIR’s Limited 3-Year Warranty. Visit
www.flir.com/testwarranty to read the warranty document.
Customer Support
Customer Support Telephone List https://support.flir.com/contact
Repair, Calibration, and Technical Support https://support.flir.com
#NAS100218; r. AD/97201/97216; en-US 2

Tuotetiedot

Merkki: Flir
Kategoria: Mittauslaitteet
Malli: MR40

Tarvitsetko apua?

Jos tarvitset apua merkille Flir MR40 esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Mittauslaitteet Flir Käyttöohjeet

Flir

Flir MR40 Käyttöohje

5 Tammikuuta 2025
Flir

Flir Cx5 Käyttöohje

27 Lokakuuta 2024

Mittauslaitteet Käyttöohjeet

Viimeisimmät Mittauslaitteet Käyttöohjeet

Sauter

Sauter FA 50 Käyttöohje

4 Tammikuuta 2025
Sauter

Sauter 281-101 Käyttöohje

3 Tammikuuta 2025
Sauter

Sauter TI-HED Käyttöohje

3 Tammikuuta 2025
Sauter

Sauter HEA 100 Käyttöohje

3 Tammikuuta 2025
Sauter

Sauter 283-502 Käyttöohje

3 Tammikuuta 2025
Sauter

Sauter FC 1K-BT Käyttöohje

3 Tammikuuta 2025
Sauter

Sauter 283-302 Käyttöohje

3 Tammikuuta 2025
Sauter

Sauter TVL-XL Käyttöohje

3 Tammikuuta 2025
Sauter

Sauter 281-301 Käyttöohje

3 Tammikuuta 2025