IMPORTANT SAFETY INSTRUCTIONS:
1) Please read all instructions.
2) Keep these instructions for future reference.
3) Heed all warnings and safety instructions.
4) Follow all instructions.
5) Do not use the PLUGLOCK in or near water.
6) Always protect the power cord from being walked on or pinched particularly at receptacles, and at the point which the cord
exits the PLUGLOCK.
7) WARNING: This device must be connected to an AC outlet with a protective earth ground connection.
8) The AC plug shall remain unobstructed and readily operable.
9) WARNING: Do not expose to rain or moisture.
C A U T I O N
R I S K O F E L E C T R IC S H OC K
D O N O T O P E N
R IS Q U E D E C HO C E L E C T R IQ UE
N E PA S O UV R
IR
Core Brands / Furman /152908
INSTRUCTIONS
The PLUGLOCK is the secure solution to the “Wall Wart”
problem. Install the PLUGLOCK safely out of sight in the back
of your rig or component rack, and the five widely spaced
locking outlets secure all of your bulky transformers or tra-
ditional plugs in place. The sturdy, all steel construction and
circuit breaker protected design ensure maximum durability
while protecting your valuable electronic equipment from
power interruptions due to accidental cord disconnections.
The unique adjustable clamping system accommodates
transformers and traditional plugs from 0.4” to 2.1” above
each outlet. To adjust outlet clamps, simply turn thumbscrews
(located on rear panel) left (counterclockwise) to loosen,
adjust to your desired height, then turn thumbscrews right
(clockwise) to tighten and secure the transformer or plug in
place.
Note that the PLUGLOCK is a power distribution device only,
and offers no conditioning or surge protection functions,
making it an ideal extension to an existing Furman power
management component.
MAXIMUM LOAD:
The five outlets are protected by a circuit breaker rated at 15
Amps, which is equivalent to 1800 Watts at 120 Volts. If the
total load on the PLUGLOCK (combining all outlets) exceeds
15 Amps, the circuit breaker (located on the side panel) will
trip, cutting off power to all connected equipment. Should this
happen, reduce the load by unplugging one or more units
from the PLUGLOCK, then push the circuit breaker button in
to reset it. The PLUGLOCK is a cCSAus safety agency listed
product.
CAUTION:
Only for use with 15 Amp circuits utilizing a minimum of
14 AWG.
DIN-00036 - A
Furman, 1800 S. McDowell Blvd., Petaluma CA 94954 • www.furmansound.com • 800-472-5555
C US
© 2014 Core Brands LLC. All rights reserved. Furman is a registered trademark of Core Brands LLC a company of Nortek, Inc.

Tuotetiedot

Merkki: Furman
Kategoria: Ei luokiteltu
Malli: PLUGLOCK

Tarvitsetko apua?

Jos tarvitset apua merkille Furman PLUGLOCK esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Ei luokiteltu Furman Käyttöohjeet

Furman

Furman CN-2400S Käyttöohje

21 Lokakuuta 2024
Furman

Furman PST-8D Käyttöohje

21 Lokakuuta 2024
Furman

Furman SPR-16E i Käyttöohje

19 Lokakuuta 2024
Furman

Furman PLUGLOCK Käyttöohje

19 Lokakuuta 2024
Furman

Furman CN-3600SE Käyttöohje

19 Lokakuuta 2024

Ei luokiteltu Käyttöohjeet

Viimeisimmät Ei luokiteltu Käyttöohjeet