Growatt ATS-US Käyttöohje

Lue alta 📖 käyttöohje suomeksi merkille Growatt ATS-US (2 sivua) kategoriassa Ei luokiteltu. Tämä opas oli hyödyllinen 3 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/2
Introduction
1
1
1
11.
.
.
..
The location of ATS-US in the system
2
2
2
22.
.
.
..
The Auto Transfer Transformer (ATS-US) controls the switch of the contactors to provide power to the critical load stated as EPS Emergency
Power Supply load in both grid-tied and off-grid conditions. There is a contactor in ATS-US to provide user a simple connection. ATS-US is
operating with PCS inverter for the purpose of providing the split phase power when grid accidentally or unexpectedly goes off. This
approach allows the home critical contunously to be supplied.
Configuration
3
3
3
33.
.
.
..
As shown in chart 2.1, the input side of ATS-US is connected with
EPS output of hybrid inverter and grid, the output side is
connected with critical load stated as EPS load. EPS Load is set
default to connect with Grid power.If Grid is lost, EPS Load will
turn the switch to EPS output of hybrid inverter. And there is a
transformer in ATS-US, it can transform 240V to 120/240V split
phase to provide the power to critical load.
AC
Brea k er
Brea k er
Hybrid Invert er
DC
Brea k er
AC
Brea k er
Sens or
Load
PV Array Battery
EPS Grid
Elec tr ic al Grid
ATS E
Load
EPS
Auto transformer
RS D1
Model name
ATS-US
Grid Rated Voltage
240V
Grid Rated Frequency
50 /60Hz
Grid Rated Current
21 a.c.A ,48 a.c.A
EPS Rated Voltage
240V
EPS Rated Frequency
50 /60Hz
EPS Rated Current
21 a.c.A,48 a.c.A
Load Rated Voltage
120/240V
Load Rated Current
21 a.c.A,48 a.c.A
Load Rated power(L-L)
5000VA,11400VA
Load Rated balanced power(L-N)
5000VA,11400VA
Load Rated unbalanced power(L-N)
3000W
Cooling Concept
Natural
Ingress Protection
IP65/NEMA type 4X
Installation
Wall Mountable
Operation Ambient Temperature
- ℃~ ℃(25 +50 -13 to+122°F)
Weight
15.6kg/34.3lb
Size
480*275*105mm/18.9*10.8*4.1in
General Information - Parts List
4
4
4
44.
.
.
..
Part List
Item
Item Name
Qty
Item
Item Name
Qty
A
ATS-US (Auto
Transfer
Transformer
1
E
Fixing screws
2
B
User Manual
1
/
/
/
C
Anchor Bolt
3
/
/
/
D
Key
2
/
/
/
Dimension & Weight
5
5
5
55.
.
.
..
Dimension (L x W x H): 480*275*105mm/18.9*10.8*4.1in
Weight: 15.6KG/34.3lb
Tools
6
6
6
66.
.
.
..
NO.
1
2
3
4
Wall Mount Installation
7
7
7
77.
.
.
..
a. Please reserve the space of 300mm (11.81in) from ATS-US.
b. Place the wall bracket horizontally on the wall and mark the
position of 3 holes for screws.
c. Remove the wall mount and drill 3 holes were marked, Drill
holes with φ10 drill Depth: at least 40mm (1.575in).
d. First knock expansion pipe into the hole with Rubber
hammer and then place the wall bracket align with the marked
position on the wall. Last, screw the self-tapping screwing into
the expansion pipe.
e. Tighten the screws on both sides of the wall bracket.
Open the ATS-US
8
8
8
88.
.
.
..
As shown above, please put the key into the Keyhole on the ATS-
US top right and bottom right and clockwise rotation to 90°.The
cover can be opended. Rotate 90 ° counterclockwise to remove the
key. The cover can be pressed directly to close the cover.
(E)
(D)
(A) (C)
(B)
ab
ab
ab
ab
Above a ATS 5000T-US,b:ATS 11400T-US :
ATS -US Series Quick Guide
ab
ATS-US usage methods
1
1
1
110
0
0
00.
.
.
..
Wiring Connection
9
9
9
99.
.
.
..
9.1 W
W
W
WWi
i
i
iir
r
r
rre
e
e
ees M
s M
s M
s Ms Ma
a
a
aak
k
k
kki
i
i
iin
n
n
nng
g
g
gg
1. Wires be low are needed before installation.
Cable des cription
Cable
Type
Conductor Cross-
section al Area Range
Source
AC GRID power
cable
1.Use cables that can with stand
90°C (194 °F) or 105°C (221°F).
2.use four single-core outdoor
copper ca bles (L1, N, L2, PE).
L1, N, L2:106 AWG
PE: 6 AWG
Purchas ed by
custome r
EPS power c able
1.Use cables that can with stand
90°C (194 °F) or 105°C (221°F).
2.Two single-core outdoor copper
cables (L 1 and L2)
126 AWG
Purchas ed by
custome r
EPS outpu t power
cable
1.Use cables that can with stand
90°C (194 °F) or 105°C (221°F).
2.use four single-core outdoor
copper ca bles (L1, N, L2, PE).
L1, N, L2:106 AWG
PE: 6 AWG
Purchas ed by
custome r
2. Use the di agonal plier t o trip 15mm of insulation from one s ide of the 10AWG wires (7pcs).
Use the diagonal plier to trip one side of GND wire about 7mm (3 pcs).
9.2 B
B
B
BBA
A
A
AAC
C
C
CCK
K
K
KKU
U
U
UUP
P
P
PP C
C
C
C Co
o
o
oon
n
n
nnn
n
n
nne
e
e
eec
c
c
cct
t
t
tti
i
i
iio
o
o
oon
n
n
nn
1.Use the screwdriver to l oosen screws in positions L1 an d L2 at the contactor’s BACKU P inpu ts.
2 Insert L 1 and L2 of the backu p conductors into the BACKUP input te rminals of L1 an d L2..
3 Tighten to 2.5Nm..
4 Use the sc rewdriver to se cure the backup EGC to the ground ing bus bar..
9.4 L
L
L
LLO
O
O
OOA
A
A
AAD C
D C
D C
D CD Co
o
o
oon
n
n
nnn
n
n
nne
e
e
eec
c
c
ccr
r
r
rri
i
i
iio
o
o
oon
n
n
n n
After connecting th e ATS-US internal wire, close the cover and the GR ID and EPS end of th e ATS-US are respectively connected with the AC
GRID and EPS output of inverter, EPS load end access load. Run the system, loa ded into normal o peration.
Trouble shooting
1
1
1
111
1
1
11.
.
.
..
1. In the pro cess of use, if EPS l oad does not work in on-grid cond ition, pleas e turn off the inverter and turn off the switch of grid input. Then
open the ATS-US cov er, check the GRID a nd EPS LOAD line is connected properly.
2. If there is no power in load in off-grid conditio n, please turn off the inverter and open the ATS-US cover, check the control line, the EPS
wiring and the EPS LOAD wiring is properly.
1. Please use the equipme nt within the scope of specification. Excess ive current or voltage may caus e device damage.
2. To avoid persona l injury due to energy hazard, remove wristwa tches and jewelry when repair ing. Use tools with insulated handles.
3.The rated power o f secondary side L1-N and L2-N cou ld up to 5KVA respectively,and power difference b etween the t ow split phases can not
exceed 3KW.
4.Don't c onnect N of ATS together wi th N of grid.
5.Don't c onnect N of ATS to PE of ATS or PE of grid.
6. Repair is to be performe d only by qualified technical p ersonal autho rized by manufacturer.
The rated b alanced powe r(L-N)means t he Load of L1-N and L2-N is equal.
The rated u nbalanced po wer(L-N)means the load of L1-N and L2-N is different.
Caution
1
1
1
112
2
2
22.
.
.
..
GR-UM-1 98-A-06
a
8b
8
a
b
9.3 G
G
G
GGR
R
R
RRI
I
I
IID C
D C
D C
D CD Co
o
o
oon
n
n
nnn
n
n
nne
e
e
eec
c
c
cct
t
t
tti
i
i
iio
o
o
oon
n
n
n n
b
a b
b
a
9.5 C
C
C
CCh
h
h
hhe
e
e
eec
c
c
cck
k
k
kki
i
i
iin
n
n
nng
g
g
gg
Please ma ke sure that all w iring in the ATS-US is tightened.
Picture above a:ATS 5000T-US, b:ATS 11400T-US
10AWGab
8AWG
10AWGa b
8AWG
10AWGa b
8AWG
10AWGab
8AWG
10AWGab
8AWG
Picture above a ATS 5000T-US, b ATS 11400T-US : :
Picture above a ATS 5000T-US, b ATS 11400T-US : :
a
Growatt New Energy
Downloa d
Manual
1. Use the sc rewdriver to lo osen screws in positions L1 and L2 at the contactor's GRID inputs.
2. Insert L1 and L2 of the GRID conductors in to the GRID input terminals of L1 and L 2.
3. Tighten to 2.5Nm.
4. Use scre wdriver to secu re the GRID EGC to the grounding bus bar.
1. Use the sc rewdriver to lo osen the three s crews on the LOAD t erminals.
2. Insert L1, L2, and N of the LOAD conductors i n to the L1 ,L2, and LOAD terminals.
3. Tighten to 3.5Nm.
4. Use scre wdriver to secu re the LOAD EGC to the grounding bu s bar.

Tuotetiedot

Merkki: Growatt
Kategoria: Ei luokiteltu
Malli: ATS-US

Tarvitsetko apua?

Jos tarvitset apua merkille Growatt ATS-US esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Ei luokiteltu Growatt Käyttöohjeet

Ei luokiteltu Käyttöohjeet

Viimeisimmät Ei luokiteltu Käyttöohjeet

Digitus

Digitus DA-90411 Käyttöohje

4 Joulukuuta 2024
Brandson

Brandson 306918 Käyttöohje

4 Joulukuuta 2024
MSI

MSI Force GC20 V2 Käyttöohje

4 Joulukuuta 2024
Hager

Hager LVTG1000CP Käyttöohje

4 Joulukuuta 2024
Hager

Hager RED113X Käyttöohje

4 Joulukuuta 2024
Hager

Hager TYA610A Käyttöohje

4 Joulukuuta 2024
Hager

Hager RED112X Käyttöohje

4 Joulukuuta 2024
Hager

Hager 80161869 Käyttöohje

4 Joulukuuta 2024
Hager

Hager 80162865 Käyttöohje

4 Joulukuuta 2024
Hager

Hager 80161865 Käyttöohje

4 Joulukuuta 2024