Hikmicro Pocket1 Käyttöohje
Hikmicro
Mittauslaitteet
Pocket1
Lue alta 📖 käyttöohje suomeksi merkille Hikmicro Pocket1 (49 sivua) kategoriassa Mittauslaitteet. Tämä opas oli hyödyllinen 13 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä
Sivu 1/49

Handheld Thermography Camera
HIKMICRO Pocket Series
User Manual

Handheld Thermography Camera User Manual
i
Legal Informaon
© 2022 Hangzhou Microimage Soware Co., Ltd. All rights reserved.
About this Manual
The Manual includes instrucons for using and managing the Product.
Pictures, charts, images and all other informaon hereinafter are for
descripon and explanaon only. The informaon contained in the
Manual is subject to change, without noce, due to rmware updates or
other reasons. Please nd the latest version of this Manual at the
HIKMICRO website ( hp://www.hikmicrotech.com).
Please use this Manual with the guidance and assistance of professionals
trained in supporng the Product.
Trademarks
and other HIKMICRO's trademarks and logos are
the properes of HIKMICRO in various jurisdicons.
Other trademarks and logos menoned are the properties of their
respecve owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS
MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE,
SOFTWARE AND FIRMWARE, ARE PROVIDED "AS IS" AND "WITH ALL
FAULTS AND ERRORS". HIKMICRO MAKES NO WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY,
SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE
USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKMICRO BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL,
INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS,
DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR
LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION,
WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING

Handheld Thermography Camera User Manual
ii
NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION
WITH THE USE OF THE PRODUCT, EVEN IF HIKMICRO HAS BEEN ADVISED
OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR
INHERENT SECURITY RISKS, AND HIKMICRO SHALL NOT TAKE ANY
RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR
OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK,
VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER,
HIKMICRO WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL
APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING
THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU
ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES
NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT
LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR
DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE
THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE
DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION,
THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL
WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR
EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF
HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE
APPLICABLE LAW, THE LATTER PREVAILS.

Handheld Thermography Camera User Manual
iii
Regulatory Informaon
FCC Informaon
Please take aenon that changes or modication not expressly
approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protecon against
harmful interference in a residenal installaon. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instrucons, may cause harmful
interference to radio communicaons. However, there is no guarantee
that interference will not occur in a parcular installaon. If this
equipment does cause harmful interference to radio or television
recepon, which can be determined by turning the equipment o and on,
the user is encouraged to try to correct the interference by one or more
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit dierent from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help
This equipment should be installed and operated with a minimum
distance 20cm between the radiator and your body.
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to
the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operaon.

Handheld Thermography Camera User Manual
iv
Note: Due to the device size limit, the above statement may not be
disclaimed on the device.
This equipment complies with FCC radiaon exposure limits set forth for
an uncontrolled environment.
EU Conformity Statement
This product and - if applicable - the supplied accessories too
are marked with "CE" and comply therefore with the
applicable harmonized European standards listed under the
Direcve 2014/30/EU (EMCD), Direcve 2014/35/EU (LVD),
Direcve 2011/65/EU (RoHS).
Restricons in the 5 GHz band:
According to Arcle 10 (10) of Direcve 2014/53/EU, when
operang in the 5150 to 5350 MHz frequency range, this
device is restricted to indoor use in: Austria (AT), Belgium (BE),
Bulgaria (BG), Croatia (HR), Cyprus (CY), the Czech Republic
(CZ), Denmark (DK), Estonia (EE), Finland (FI), France (FR),
Germany (DE), Greece (EL), Hungary (HU), Iceland (IS), Ireland
(IE), Italy (IT), Latvia (LV), Liechtenstein (LI), Lithuania (LT),
Luxembourg (LU), Malta (MT), Netherlands (NL), Northern
Ireland (UK(NI)), Norway (NO), Poland (PL), Portugal (PT),
Romania (RO), Slovakia (SK), Slovenia (SI), Spain (ES), Sweden
(SE), Switzerland (CH), and Turkey (TR).
The frequency bands and the nominal limits of transmied
power (radiated and/or conducted) applicable to this radio
device are the following:
2.4 G Wi-Fi (2.4 GHz to 2.4835 GHz)
20 dBm
Bluetooth (2.4 GHz to 2.4835 GHz)
20 dBm
5 G Wi-Fi (5.15 to 5.25 GHz)
23 dBm
5 G Wi-Fi (5.25 to 5.35 GHz)
23 dBm

Handheld Thermography Camera User Manual
v
5 G Wi-Fi (5.47 to 5.725 GHz)
23 dBm
5 G Wi-Fi (5.725 to 5.85 GHz)
14 dBm
Direcve 2012/19/EU (WEEE Direcve): Products marked with
this symbol cannot be disposed of as unsorted municipal
waste in the European Union. For proper recycling, return this
product to your local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated collecon
points. For more informaon see: www.recyclethis.info
Direcve 2006/66/EC and its amendment 2013/56/EU
(Baery Direcve): This product contains a baery that
cannot be disposed of as unsorted municipal waste in the
European Union. See the product documentation for specic
baery informaon. The baery is marked with this symbol,
which may include leering to indicate cadmium (Cd), lead
(Pb), or mercury (Hg). For proper recycling, return the battery
to your supplier or to a designated collecon point. For more
informaon see:www.recyclethis.info
Industry Canada ICES-003 Compliance
This device complies with Industry Canada licence-exempt RSS
standard(s). Operaon is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that
may cause undesired operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables
aux appareils radioexempts de licence. L'exploitation est autorisée aux
deux condions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est suscepble d'en compromere le
fonconnement.

Handheld Thermography Camera User Manual
vi
This equipment complies with IC RSS-102 radiaon exposure limits set
forth for an uncontrolled environment.
ce matériel est conforme aux limites de dose d'exposion aux
rayonnements, CNR-102 énoncée dans un autre environnement.
(i) The device for operaon in the band 5150-5250 MHz is only for indoor
use to reduce the potenal for harmful interference to co-channel mobile
satellite systems;
(ii) The maximum antenna gain permied for devices in the bands
5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit;
and
(iii) The maximum antenna gain permied for devices in the band
5725-5825 MHz shall comply with the e.i.r.p. limits specied for
point- -point and non point- -point operaon as appropriate. to to
(i)Les disposifs fonconnant dans la bande 5150-5250 MHz sont
réservés uniquement pour une ulisaon à l'intérieur an de réduire les
risques de brouillage préjudiciable aux systèmes de satellites mobiles
ulisant les mêmes canaux.
(ii) Le gain d'antenne maximal autorisé pour les appareils dans les bandes
5250-5350 MHz et 5470-5725 MHz doivent respecter le pire limiter; et
(iii) Le gain d'antenne maximal autorisé pour les appareils dans la bande
5725-5825 MHz doivent respecter le pire limites spéciées pour le
point-à-point et l'exploitaon non point à point, le cas échéant.
Users should also be advised that high-power radars are allocated as
primary users (i.e. priority users) of the bands 5250-5350 MHz and
5650-5850 MHz and that these radars could cause interference and/or
damage to LE-LAN devices.
Les ulisateurs de radars de haute puissance sont désignés ulisateurs
principaux (c.-à-d., qu'ils ont la priorité) pour les bandes 5250-5350 MHz

Handheld Thermography Camera User Manual
vii
et 5650-5850 MHz et que ces radars pourraient causer du brouillage
et/ou des dommages aux disposifs LAN- EL.
KC
B급 기기: 이 기기는 가정용(B급) 전자파적합기기로써 주로 가정에서
사용하는 것을 목적으로 하며, 모든 지역에서 사용할 수 있습니다.

Handheld Thermography Camera User Manual
viii
Symbol Convenons
The symbols that may be found in this document are dened as follows.
Symbol
Descripon
Danger
Indicates a hazardous situaon which, if not
avoided, will or could result in death or serious
injury.
Cauon
Indicates a potenally hazardous situation which, if
not avoided, could result in equipment damage,
data loss, performance degradaon, or unexpected
results.
Note
Provides addional informaon to emphasize or
supplement important points of the main text.

Handheld Thermography Camera User Manual
ix
Safety Instrucon
These instrucons are intended to ensure that user can use the product
correctly to avoid danger or property loss.
Laws and Regulaons
●
Use of the product must be in strict compliance with the local electrical
safety regulaons.
Transportaon
●
Keep the device in original or similar packaging while transporng it.
●
Keep all wrappers aer unpacking them for future use. In case of any
failure occurred, you need to return the device to the factory with the
original wrapper. Transportaon without the original wrapper may
result in damage on the device and the company shall not take any
responsibilies.
●
DO NOT drop the product or subject it to physical shock. Keep the
device away from magnec interference.
Power Supply
●
Input voltage should meet the Limited Power Source (3.85 VDC, 570 mA)
according to the IEC62368 standard. Please refer to technical
specicaons for detailed informaon.
●
Make sure the plug is properly connected to the power socket.
●
DO NOT connect multiple devices to one power adapter, to avoid
over-heang or re hazards caused by overload.
●
Use the power adapter provided by a qualied manufacturer. Refer to
the product specicaon for detailed power requirements.
Baery
●
Improper use or replacement of the baery may result in explosion
hazard. Replace with the same or equivalent type only. Dispose of used
baeries in conformance with the instrucons provided by the baery

Handheld Thermography Camera User Manual
x
manufacturer.
●
The built-in baery cannot be dismantled. Please contact the
manufacture for repair if necessary.
●
For long-term storage of the baery, make sure it is fully charged every
half year to ensure the baery quality. Otherwise, damage may occur.
●
Use the baery provided by a qualied manufacturer. Refer to the
product specicaon for detailed baery requirements.
●
DO NOT charge other baery types with the supplied charger. Conrm
there is no ammable material within 2 m of the charger during
charging.
●
DO NOT place the baery near heang or re source. Avoid direct
sunlight.
●
DO NOT swallow the battery to avoid chemical burns.
●
DO NOT place the baery in the reach of children.
●
When the device is powered o and the RTC battery is full, the me
sengs can be kept for 6 months.
●
In the rst use, charge the device for more than 2.5 hours in the
power-o status.
●
The lithium baery voltage is 3.85 V, and the battery capacity is 00 21
mAh.
●
The baery is cerfied by UL2054.
Maintenance
●
If the product does not work properly, please contact your dealer or the
nearest service center. We shall not assume any responsibility for
problems caused by unauthorized repair or maintenance.
●
A few device components (e.g., electrolyc capacitor) require regular
replacement. The average lifespan varies, so periodic checking is
recommended. Contact your dealer for details.
●
Wipe the device gently with a clean cloth and a small quantity of
ethanol, if necessary.
●
If the equipment is used in a manner not specified by the manufacturer,
the protecon provided by the device may be impaired.

Handheld Thermography Camera Pocket Series User Manual
22
Chapter 6 Connect Bluetooth
You can record and hear the sound contained in the videos via bluetooth
headsets aer pairing the device with bluetooth headsets successfully.
Steps
1. Select from the main menu.
2. Go to . Local Seings → Connect Bluetooth→
3. Tap to enable the bluetooth.
Note
You can also press to quit pairing.
The device will search the nearby enabled bluetooth headsets and pair
them automacally.
Result
Aer pairing you can record and hear the sound via the headsets while
recording and playing the video or image.

Handheld Thermography Camera Pocket Series User Manual
23
Chapter 7 Set LED Light
Tap the ashlight buon on the swipe-down menu to enable the LED
light.

Handheld Thermography Camera Pocket Series User Manual
24
Chapter 8 Cast Screen
You can connect the device to your PC via a type-C cable, and cast the
real-me live view of the device to your PC through the UVC alarm client.
Then you can synchronously view the live view and parameters such as
the maximum temperature, the distance, and the emissivity on your PC.
Before You Start
Download the UVC Alarm Client from HIKMICRO oicial website, and
install the client on your PC. Refer to the user manual of the client for
detailed operaon.
Steps
1. Select from the main menu.
2. Go to Local Sengs → Connect Cast Screen→ .
3. Tap to enable the funcon.
4. Open UVC Alarm Client on your PC.
4. Connect the device to your PC via a type-C cable.
Result
The live view interface and parameters the current image will be of
synchronously displayed on your PC.

Handheld Thermography Camera Pocket Series User Manual
25
Chapter 9 Set Macro Mode
In the macro mode, you can focus extremely close on a very small object,
and the object appears much larger in the view (and in the nal image)
compared to the standard lens.
Before You Start
Install the macro lens before using this funcon. Refer to the quick start
guide of the macro lens for detailed operaon.
The macro lens is not included in the package. Please purchase it
separately. The recommended model is HM-P201- MACRO.
Steps
1. Select from the main menu.
2. Go to Local Sengs → Capture Sengs Macro Mode→ .
3. Tap to enable the funcon.
Note
●
Aer the macro mode is enabled only the emissivity can be modied. ,
Parameters such as distance, image mode, parallax correcon, and
measurement range cannot be modied.
●
Aer this funcon is disabled, the parameters will be restored to the
previous set values and the measurement range will be set to auto
switch.

Handheld Thermography Camera Pocket Series User Manual
26
Chapter Thermal View APP Connecon 10
The device supports both Wi-Fi connecon and hotspot. Connect the
device to HIKMICRO Viewer, and you can control the device via mobile
client.
10.1 Connect via Wi- Fi
Before You Start
Download and install HIKMICRO Viewer on your phone.
Steps
1. Select from the main menu.
2. Go to . Local Sengs → Connect → WLAN
3. Tap to enable Wi-Fi, and the searched Wi-Fi will be listed .
Figure 9-1 Wi-Fi List
4. Select the - connect . A so keyboard is displayed. Wi Fi to to
5. Enter the password by touching the screen.
Note
DO NOT tap or , or the password may be incorrect. enter space
6. Tap to save.

Handheld Thermography Camera Pocket Series User Manual
27
7. Launch the App and follow the startup wizard to create, and register an
account.
8 Add the device to online devices. .
Result
You can view the live view, capture snapshots, and record videos via the
App.
10.2 Connect via Hotspot
Before You Start
Download and install HIKMICRO Viewer on your phone.
Steps
1. Select from the main menu.
2. Go to . Local Seings → Connect → Hotspot
2. Tap to enable the hotspot function. The hotspot name is the last
9 digits of the device serial No.
3. Tap . A so keyboard is displayed. Set Hot Spot
Figure 9-2 Set Hotspot
4. Set the password for the hotspot.
Note
●
DO NOT tap or , or the password may be incorrect. enter space
Tuotetiedot
Merkki: | Hikmicro |
Kategoria: | Mittauslaitteet |
Malli: | Pocket1 |
Tarvitsetko apua?
Jos tarvitset apua merkille Hikmicro Pocket1 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Mittauslaitteet Hikmicro Käyttöohjeet

11 Tammikuuta 2025

11 Tammikuuta 2025

11 Tammikuuta 2025

11 Tammikuuta 2025

1 Tammikuuta 2025
Mittauslaitteet Käyttöohjeet
- Mittauslaitteet MSW
- Mittauslaitteet Stamos
- Mittauslaitteet ORNO
- Mittauslaitteet EBERLE
- Mittauslaitteet Hazet
- Mittauslaitteet Fluke
- Mittauslaitteet IFM
- Mittauslaitteet Megger
- Mittauslaitteet Kogan
- Mittauslaitteet Festo
- Mittauslaitteet Topex
- Mittauslaitteet AkYtec
- Mittauslaitteet Voltcraft
- Mittauslaitteet NEO Tools
- Mittauslaitteet Panasonic
- Mittauslaitteet Klein Tools
- Mittauslaitteet Schneider
- Mittauslaitteet PeakTech
- Mittauslaitteet Clean Air Optima
- Mittauslaitteet Flex
- Mittauslaitteet Chauvin Arnoux
- Mittauslaitteet CSL
- Mittauslaitteet Milwaukee
- Mittauslaitteet Elgato
- Mittauslaitteet Kern
- Mittauslaitteet Ansmann
- Mittauslaitteet Einhell
- Mittauslaitteet Mitsubishi
- Mittauslaitteet PCE
- Mittauslaitteet Noyafa
- Mittauslaitteet Megasat
- Mittauslaitteet Reely
- Mittauslaitteet Rigol
- Mittauslaitteet Joy-it
- Mittauslaitteet Logilink
- Mittauslaitteet Basetech
- Mittauslaitteet Gossen Metrawatt
- Mittauslaitteet TFA
- Mittauslaitteet PCE Instruments
- Mittauslaitteet Sauter
- Mittauslaitteet Owon
- Mittauslaitteet Extech
- Mittauslaitteet Techno Line
- Mittauslaitteet Murideo
- Mittauslaitteet Stabila
- Mittauslaitteet Grundfos
- Mittauslaitteet Vemer
- Mittauslaitteet Uni-T
- Mittauslaitteet Sonel
- Mittauslaitteet Flir
- Mittauslaitteet Steinberg
- Mittauslaitteet Testo
- Mittauslaitteet Burg-Wachter
- Mittauslaitteet Metrix
- Mittauslaitteet Technics
- Mittauslaitteet Brookhuis
- Mittauslaitteet Toolland
- Mittauslaitteet Kyoritsu
- Mittauslaitteet Angler
- Mittauslaitteet Testboy
- Mittauslaitteet Ebro
- Mittauslaitteet Wachendorff
- Mittauslaitteet Senseca
- Mittauslaitteet Crowcon
- Mittauslaitteet DriveTest
- Mittauslaitteet PQ Plus
- Mittauslaitteet Intact
- Mittauslaitteet Aeroqual
- Mittauslaitteet Helvi
- Mittauslaitteet Aerospace Logic
- Mittauslaitteet MGL Avionics
- Mittauslaitteet Dostmann Electronic
- Mittauslaitteet Kopp
- Mittauslaitteet Kübler
- Mittauslaitteet HT Instruments
- Mittauslaitteet Rotronic
- Mittauslaitteet Ideal
- Mittauslaitteet CEM
- Mittauslaitteet Jonard Tools
- Mittauslaitteet Phoenix Contact
- Mittauslaitteet Victron Energy
- Mittauslaitteet Testec
- Mittauslaitteet Eastron
- Mittauslaitteet GW Instek
- Mittauslaitteet Beha-Amprobe
- Mittauslaitteet Camille Bauer
- Mittauslaitteet Siglent
- Mittauslaitteet PICO
- Mittauslaitteet Enda
- Mittauslaitteet Ermenrich
- Mittauslaitteet Adwa
- Mittauslaitteet Tempo
- Mittauslaitteet Duro Pro
- Mittauslaitteet Aim TTi
- Mittauslaitteet BAXTER
- Mittauslaitteet Softing
- Mittauslaitteet Metrel
- Mittauslaitteet Mitutoyo
Viimeisimmät Mittauslaitteet Käyttöohjeet

3 Huhtikuuta 2025

3 Huhtikuuta 2025

3 Huhtikuuta 2025

3 Huhtikuuta 2025

3 Huhtikuuta 2025

3 Huhtikuuta 2025

3 Huhtikuuta 2025

3 Huhtikuuta 2025

3 Huhtikuuta 2025

3 Huhtikuuta 2025