Operating instructions
Evaluation system for flow sensors
SR0152
704949 / 01 07 / 2013
UK

2
1 Preliminary note
The operating instructions are part of the unit. They contain information about the
correct handling of the product. Read them before use to get familiar with operat-
ing conditions, mounting and operation. Adhere to the safety instructions. The
operating instructions are made for authorised persons according to the EMC and
low voltage guidelines.
Contents
1 Preliminary note 2 ...................................................................................................
2 Safety instructions 3 ...............................................................................................
3 Function and features 4 ..........................................................................................
4 Mounting ..............................................................................................................4
4.1 Mounting of the sensors 5 ................................................................................
5 Electrical connection 5 ............................................................................................
5.1 Terminal connection 6 .......................................................................................
5.2 Power supply (Power) 6 ..................................................................................
5.3 Connection of sensors 7 ...................................................................................
5.4 Relay outputs 7 ................................................................................................
6 Settings ...............................................................................................................7
7 Operation ............................................................................................................8
7.1 Function diagram flow monitoring 8 .................................................................
8 Maintenance, repair, disposal 9 .............................................................................
9 Technical data and scale drawing 9 ........................................................................

3
UK
2 Safety instructions
• Adhere to the operating instructions. Non-observance of the instructions,
operation which is not in accordance with use as prescribed below, wrong in-
stallation or incorrect handling can affect the safety of operators and machinery.
• The unit must only be installed, connected and put into operation by a qualified
electrician as during the installation dangerous voltages may be exposed. The
safe function of the unit and the plant is only guaranteed when installation is
correctly carried out.
• Disconnect the unit externally before handling it. Also disconnect any indepen-
dently supplied relay load circuits.
• Be careful when handling the unit once power is applied. This is only allowed
by qualified personnel due to the protection rating IP 20.
• The design of the unit corresponds to protection class II (EN 61010) except for
the terminal blocks. Protection against accidental contact (safety from finger
contact to IP20) for qualified personnel is only ensured if the terminals have
been completely inserted. For this reason the unit must always be installed in a
control cabinet which can only be opened with a tool, for pollution degree 2 and
overvoltage category II.
• For DC units the external 24 V DC supply must be generated and supplied ac-
cording to the requirements for safe extra-low voltage (SELV) since this voltage
is provided near the operating elements and at the terminals for the supply of
sensors without further protection measures.
• In case of malfunction of the unit or queries please contact the manufacturer.
Any tampering with the device can seriously affect the safety of operators and
machinery. This is not permitted and leads to an exclusion of liability and war-
ranty.
Tuotetiedot
Merkki: | IFM |
Kategoria: | Mittauslaitteet |
Malli: | SR0152 |
Tarvitsetko apua?
Jos tarvitset apua merkille IFM SR0152 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Mittauslaitteet IFM Käyttöohjeet

5 Joulukuuta 2024

5 Joulukuuta 2024

5 Joulukuuta 2024

5 Joulukuuta 2024

5 Joulukuuta 2024

5 Joulukuuta 2024

5 Joulukuuta 2024

5 Joulukuuta 2024

5 Joulukuuta 2024

5 Joulukuuta 2024
Mittauslaitteet Käyttöohjeet
- Mittauslaitteet ORNO
- Mittauslaitteet EBERLE
- Mittauslaitteet Hazet
- Mittauslaitteet Fluke
- Mittauslaitteet Megger
- Mittauslaitteet Kogan
- Mittauslaitteet Festo
- Mittauslaitteet AkYtec
- Mittauslaitteet Voltcraft
- Mittauslaitteet Klein Tools
- Mittauslaitteet PeakTech
- Mittauslaitteet Clean Air Optima
- Mittauslaitteet Chauvin Arnoux
- Mittauslaitteet CSL
- Mittauslaitteet Milwaukee
- Mittauslaitteet Elgato
- Mittauslaitteet Kern
- Mittauslaitteet Ansmann
- Mittauslaitteet Einhell
- Mittauslaitteet Mitsubishi
- Mittauslaitteet PCE
- Mittauslaitteet Noyafa
- Mittauslaitteet Megasat
- Mittauslaitteet Reely
- Mittauslaitteet Joy-it
- Mittauslaitteet Basetech
- Mittauslaitteet Gossen Metrawatt
- Mittauslaitteet TFA
- Mittauslaitteet PCE Instruments
- Mittauslaitteet Sauter
- Mittauslaitteet Owon
- Mittauslaitteet Extech
- Mittauslaitteet Techno Line
- Mittauslaitteet Murideo
- Mittauslaitteet Stabila
- Mittauslaitteet Uni-T
- Mittauslaitteet Sonel
- Mittauslaitteet Flir
- Mittauslaitteet Steinberg
- Mittauslaitteet Testo
- Mittauslaitteet Burg-Wachter
- Mittauslaitteet Metrix
- Mittauslaitteet Technics
- Mittauslaitteet Brookhuis
- Mittauslaitteet Toolland
- Mittauslaitteet Angler
- Mittauslaitteet Testboy
- Mittauslaitteet Ebro
- Mittauslaitteet Wachendorff
- Mittauslaitteet Crowcon
- Mittauslaitteet DriveTest
- Mittauslaitteet PQ Plus
- Mittauslaitteet Intact
- Mittauslaitteet Aeroqual
- Mittauslaitteet Helvi
- Mittauslaitteet Aerospace Logic
- Mittauslaitteet MGL Avionics
- Mittauslaitteet Dostmann Electronic
- Mittauslaitteet Kopp
- Mittauslaitteet Kübler
- Mittauslaitteet HT Instruments
- Mittauslaitteet Rotronic
- Mittauslaitteet Ideal
- Mittauslaitteet CEM
- Mittauslaitteet Jonard Tools
- Mittauslaitteet Testec
- Mittauslaitteet Eastron
- Mittauslaitteet GW Instek
- Mittauslaitteet Beha-Amprobe
- Mittauslaitteet Hikmicro
- Mittauslaitteet Camille Bauer
- Mittauslaitteet Siglent
- Mittauslaitteet PICO
- Mittauslaitteet Ermenrich
- Mittauslaitteet Adwa
Viimeisimmät Mittauslaitteet Käyttöohjeet

14 Tammikuuta 2025

14 Tammikuuta 2025

14 Tammikuuta 2025

14 Tammikuuta 2025

14 Tammikuuta 2025

14 Tammikuuta 2025

14 Tammikuuta 2025

14 Tammikuuta 2025

14 Tammikuuta 2025

14 Tammikuuta 2025