Thank you for purchasing the QBP Series Quiet Blower Panel. Please read these instructions thoroughly
before installing/operating this product
PRODUCT FEATURES
- Quiet even at full speed: proportional speed assures the quietest operation possible
- Low power consumption: blower only runs as needed and spins as fast as required by the heat
load presented
- Proprietary blowers provide high static pressure to maintain airflow even in crowded racks. Superior
to axial fans for maintaining airflow in restricted conditions
- Attractive appearance complements finished rack appearance
- 100 CFM free air rating
(International Models)
(C)
(D)
(B)
(A)
(G)
A) CONTROL CIRCUIT VENT: Allows for air flow to the control circuit. DO NOT BLOCK!
B) TURN ON TEMPERATURE: The blowers will turn on at 87° F (30.5° C) and run proportionately from
87° F (30.5° C) to 95° (35° C). At 95° F and above , the blowers will run at full speed. The blowers will
stop running at 85° F (29.4° C).
C) PRODUCT REVISION: Current revision of your QBP series model.
D) MANUFACTURING DATE CODE: Denotes the date the QBP series models was manufactured.
E) TEMPERATURE PROBE: Temperature detection probe, nine feet long.
F) POWER CONNECTOR: Connects to the provided power supply.
G) POWER LED: Blue LED that illuminates when the unit is receiving power.
FRONT VIEW
BOTTOM VIEW
(ONLY ONE FAN HAS THE TEMPERATURE
PROBE AND POWER CONNECTOR AS SHOWN)
PRODUCT CALLOUTS
(F)
(E)
Page 2
1) Install the QBP series model directly above heat producing equipment. Run the temperature probe to
the heat source. Plug the power supply into the power source and into the unit. (FIGURE A)
1) Install the QBP series model with the blower intakes facing the top of the rack. Ensure there is a vent
panel installed at the bottom of the rack to allow for air flow (or equivalent venting). Mount the
temperature probe at the highest available location in the rack. Plug the power supply into the power
source and into the unit. (FIGURE B)
APPLICATIONS
(FIGURE A)
(FIGURE B)
VENT PANEL
For thermal management guidelines visit our web site to view our thermal management white paper
http://www.middleatlantic.com/pdf/ThermalManagement.pdf
Page 3
REMOVING HEAT FROM A POPULATED RACK
REMOVING HEAT FROM A SINGLE COMPONENT
IN IONTER ATN AL M ELS Y: OD ONL S t te l g for yelec appropria wal plu ou regior n.

Tuotetiedot

Merkki: Middle Atlantic
Kategoria: Prosessorikoeler
Malli: IQBP-2

Tarvitsetko apua?

Jos tarvitset apua merkille Middle Atlantic IQBP-2 esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Prosessorikoeler Middle Atlantic Käyttöohjeet

Prosessorikoeler Käyttöohjeet

Viimeisimmät Prosessorikoeler Käyttöohjeet