Panamax MD2-TL Käyttöohje

Lue alta 📖 käyttöohje suomeksi merkille Panamax MD2-TL (2 sivua) kategoriassa Ei luokiteltu. Tämä opas oli hyödyllinen 2 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/2
Cover can be flipped around 180
degrees to hide LEDs from front
straight-on view if desired.
Cover can be removed and painted to match
color of wall. Do not paint the sides, top or
bottom. Warranty will be voided.
Cover of MD2-C can easily be removed by
pulling cover at the 2 side indents ( ).1
Unit can be securely screwed into wall
outlet faceplate using either hole ( ) 2
indicated (screw is included).
1
2
1690 Corporate Circle, Petaluma, CA 94954 • 800-472-55555 • 707-283-5900 • Fax 707-283-5901 • www.panamax.com
INSTALLATION INSTRUCTIONS MD2-C
Bottom view of productTop view
of product
INS00877-A 1/10
CUSTOMER SUPPORT:
800-472-5555
FEATURES
COAX LINE
OUT TO
EQUIPMENT LEFT SIDE
OUTLET
GROUND
PLUG OUT
RIGHT SIDE
OUTLET
GROUND
PLUG DOWN
Side views of product
1. Turn off the equipment you are plugging into the MD2-C.
2. Plug the surge protector into the wall outlet. A red "Line Fault" light
indicates an improperly wired outlet that must be checked by a qualified
electrician.
3. If the blue light is on, plug your "Power On Protection OK"
equipment into the AC outlets on the surge protector.
4. For satellite, CATV or cable modem connections: The protection
circuitry is bi-directional; line and equipment cables may be attached to
either connector. See diagram for proper coax protection.
5. Turn the connected equipment ON and check for power and correct
operation.
Panamax surge protectors and the connected equipment must be indoors in a dry location and in the same building. Do not install any
Panamax product near heat emitting appliances such as a radiator or heat register. Do not install this product where excessive
moisture is present; for example, near a bathtub, sink, pool, basement floor, fish tank, etc.
It is not uncommon for a building to be improperly grounded. In order to protect your equipment, and validate the warranty, Panamax
products must be plugged into a properly grounded 3-wire outlet. Additionally, building wiring and grounding must conform to
applicable NEC (USA) or CEC (Canada) codes for the Panamax warranty to be valid.
Do not use 2-prong adapters with this product. If an extension cord is required, use only Panamax #GEC1410. If at any time your
surge protector indicates a Line Fault, call your electrician to correct the building wiring.
Note to CATV Installers
This reminder is provided to call the CATV System Installer's attention to Article 820-40 of the NEC that provides specific guidelines for
proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as
close to the point of cable entry as practical. A separate driven ground rod is not acceptable under the code.
POWER ON /
PROTECTION OK- (blue)
normally ON - indicates
that the power is on,
surge protector is
functioning properly,
and all connected
equipment is protected.
LINE FAULT INDICATOR-
(red) - If lit red, indicates
an improperly wired outlet. AC outlets are turned 90 degrees from one
another to accommodate different style
plugs or transformers.
Properly Connecting Your Surge Protector
To completely protect your equipment from power surges, every wire leading into or out of the equipment you want to protect must be connected to the
appropriate Panamax surge protector. Damaging lightning and power surges can get into your system through any AC power or signal line (phone lines,
grounding wires, coax cables, modem cables, etc.) connected to your electrical equipment.
The $100,000 Connected Equipment Protection Policy is invalid if any wire leading into or out of the equipment is not properly connected to the
appropriate Panamax surge protector(s). The surge protector must also be plugged into a properly wired and grounded outlet. Please see the warranty
for details or contact the Panamax Customer Relations department with questions.
Overview
Make sure you have the right surge protector to protect your electronic equipment. Panamax makes protectors for almost every type of electronic
equipment. Surge protectors that may look identical from the outside can be very different on the inside. It is very important to use the surge protector
designed for your application. Two-outlet surge protectors are not designed for use with systems having more than two AC powered components.
Panamax offers a wide range of surge protectors designed for use with larger systems. If you have any questions about which product is best for your
applications, please see our web site www.panamax.com or contact Panamax Customer Relations at 800-472-5555 (7:30 a.m. – 4:30 p.m. PST).
MD2-C
LINE
IN
LINE
OUT
COAX LINE
IN FROM
WALL
OPTIONS FOR SECURITY MOUNTING & FRONT COVER FACEPLATE
POWER ON
PROTECTION OK
LINE
FAULT
TYPICAL INSTALLATION
IMPORTANT SAFETY POINTS
PROPERLY GROUNDED
AC OUTLET
COAX
LINE IN
COAXIAL
WALL
OUTLET
MD2-C
AC LINE
TELEVISION
CABLE / SAT. BOX
AC LINE
COAX
LINE OUT
Limited Lifetime Product
Warranty*
$
100,000
Limited Connected
Equipment Protection Policy*
*See documentation on back side for details.
WARRANTY LIMITATION FOR INTERNET PURCHASERS
Panamax products purchased through the Internet do not carry a valid Product Warranty or Connected Equipment Protection Policy unless purchased from an Authorized Panamax Internet Dealer and the original factory
serial numbers are intact (they must not have been removed, defaced or replaced in any way). Purchasing from an Authorized Panamax Internet Dealer insures that the product was intended for consumer use, has passed
all quality inspections and is safe. Buying through auction sites or unauthorized dealers may result in the purchase of salvaged, failed and/or products not intended for use in the US. In addition, Authorized Panamax
Internet dealers have demonstrated sufcient expertise to insure warranty compliant installations. For a list of Authorized Panamax Internet Dealers go to www.panamax.com. If you have any questions regarding these
requirements, please contact Panamax Customer Relations.
Product Upgrade Program
If your Panamax power conditioner sacrices itself
while protecting your connected equipment, you have
an option to upgrade to the latest technology. Please
go to our web site www.panamax.com or contact
Panamax Customer Relations at 800-472-5555 for
details
.
Panamax Surge Protector
Limited Lifetime
Product Warranty
Panamax warrants to the purchaser of any standard
Panamax surge protector that the surge protector shall
be free of defects in design, material, or workmanship,
and Panamax will repair or replace any defective unit.
For product replacement see “NOTIFICATION” (3).
Panamax Surge Protector
Limited Connected Equipment
Protection Policy
It is the policy of Panamax that it will, at its election,
either replace, pay to replace at fair market value, or
pay to repair, up to the dollar amount specified below,
equipment that is damaged by an AC power, cable,
telephone, or lightning surge while connected to a
properly installed Panamax power conditioner. To be
eligible for compensation, repair and or replacement,
the power conditioner must shows signs of surge dam-
age or that it is operating outside of design specifi-
cations, relative to its surge protection capability, and
under all of the circumstances failed to protect your
connected equipment.
MD2-C $100,000
THE LIMITED CONNECTED EQUIPMENT
PROTECTION POLICY IS SUBJECT TO THE
FOLLOWING CONDITIONS AND LIMI TIONS TA
1. ORIGINAL OWNERSHIP REQUIREMENT:
2. PROPER INSTALLATION: Panamax AC protectors
must be directly plugged into a properly grounded
3-wire AC outlet. Extension cords*, non-grounded
two prong adapters, or other non-Panamax surge
products must not be used. Building wiring and other
connections to protected equipment must conform to
applicable codes (NEC or CEC). No other ground wires
or ground connections may be used. All wires (includ-
ing, e.g., AC power lines, telephone lines, signal/data
lines, coaxial cable, antenna lead-ins) leading into the
protected equipment must rst pass through a single
Panamax protector designed for the particular applica-
tion. The protector and the equipment to be protected
must be indoors in a dry location, and in the same
building. Panamax installation instructions and dia-
grams must be followed
3. NOTIFICATION: You must notify Panamax within
ten days of any event precipitating request for prod-
uct replacement or payment for connected equipment
damage. A return authorization (RA) number must first
be obtained from the Panamax Customer Relations
Department at www.panamax.com** before returning
the protector Panamax. At this time, you must notify
Panamax if you believe you have a claim for damaged
connected equipment. Once you obtain an RA number,
please mark the number on the bottom of the unit and
pack it in a shipping carton/box with enough packing
material to protect it during transit. The RA number
must also be clearly marked on the outside of the car-
ton. Ship the unit Panamax. Please note that you are to
responsible for any and all charges related to shipping
the unit to Panamax. If connected equipment damage
was indicated on your RA request, Panamax will mail
you claim kit to be completed and returned within 30
days. A connection di ram of your system will be ag
required as part of the claim kit. Be sure to note its
configuration before disconnecting your equipment.
4. DETERMINATION OF FAILURE: Panamax will
evaluate the protector for surge damage. The Panamax
protector must show signs of surge damage or must
be performing outside (>10%) of design specifications
relative to its surge protection capability. Opening the
enclosure, tampering with, or modifying the unit in any
way shall be grounds for an automatic denial your
request for payment. Panamax, after evaluating all in-
formation provided, will determine whether or not your
request is eligible for payment. If the surge protector
shows no signs of AC power or signal line surge dam-
age and is working within design specifications, Pana-
max will return the unit to you with a letter explaining
the test results and notifying you of the rejection your of
claim. Exceptions: If a dealer or installer replaces the
protector for the customer, replacement will be re-
turned to the dealer installer; or if the protector is a
pre-1996 model, it will be replaced; or, for a Canadian
customer, the protector will be replaced. Panamax
reserves the right to inspect the damaged connected
equipment, parts, or circuit boards. Please note that
you are responsible for any and all charges related to
shipping the damaged equipment to Panamax. Pana-
max also reserves the right to inspect the customer’s
facility. Damaged equipment deemed uneconomical to
repair must remain available for inspection by Pana-
max until the claim is finalized.
5. REQUEST YMENTS: PA Once Panamax has deter-
mined that you are entitled to compensation, Panamax
will, at its election, either pay you the present fair mar-
ket value of the damaged equipment, or pay for the
cost of the repair, or send you replacement equipment,
or pay the equivalence of replacement equipment.
6. OTHER INSURANCE/WARRANTIES: This coverage
is secondary to any existing manufacturer’s warranty,
implied or expressed, or any insurance and/or service
contract that may cover the loss.
7. EXCLUSIONS: THE PANAMAX CONNECTED
EQUIPMENT PROTECTION POLICY DOES NOT
APPLY TO: Service charges, installation costs, rein-
stallation costs; setup cost; diagnostic charges; peri-
odic checkups; routine maintenance; loss of use of the
product; costs or expenses arising out of reprogram-
ming or loss of programming and/or data; shipping
charges or fees; service calls; loss or damage occa-
sioned by fire, theft, ood, wind, accident, abuse or
misuse, and products subject to manufacturer’s recall
or similar event.
8. DISPUTE RESOLUTION: Any controversy or claim
arising out of or relating to Panamax’s Connected
Equipment Protection Policy, or the alleged breach
thereof, shall be settled by arbitration administered by
the American Arbitration Association under its Com-
mercial Arbitration Rules. You may file for arbitration
at any AAA location in the United States upon the pay-
ment of the applicable filing fee. The arbitration will be
conducted before a single arbitrator, and will be limited
solely to the dispute or controversy between you and
Panamax. The arbitration shall be held in any mutually
agreed upon location in person, by telephone, or online.
Any decision rendered in such arbitration proceedings
will be nal and binding on each of the parties, and
judgment may be entered thereon in a court of com-
petent jurisdiction. The arbitrator shall not award either
party special, exemplary, consequential, punitive, in-
cidental or indirect damages, or attorney’s fees. The
parties will share the costs of arbitration (including the
arbitrators fees, if any) in the proportion that the nal
award bears to the amount of the initial claim.
-
THE LIMITED PRODUCT WARRANTY IS THE ONLY
WARRANTY PROVIDED WITH THIS PANAMAX
PRODUCT AND ANY OTHER IMPLIED OR EX-
PRESSED WARRANTIES ARE NON-EXISTENT.
This warranty may not be modified except in writing,
signed by an officer of the Panamax Corporation.
* The use of a Panamax extension cord or equiva-
lent (UL or CSA listed, minimum 14AWG, 3-wire
grounded) will not invalidate the warranty.
** Forms are available on the Panamax web site
for requesting RAs and opening a claim for con-
nected equipment damage.
MODEL - MD2-C
DOC. NO. IWS00877_EN REV. A
Effective Date 1/21/10
www.panamax.com
800-472-5555
Panamax’s connected equipment limited protection
policy extends to the original purchaser of the
Panamax product only and is non-transferable.
Original purchase receipts must accompany any
product return or claim for connected equipment
damage.
9. GENERAL: If you have any questions regarding the
product warranty or the connected equipment pro-
tection policy, please contact the Panamax
Customer Relations Department at www.panamax.
com.
The Limited Product Warranty and L i f e t i m e
L im i t e d Connected Equipment Policy herein super-
sede all previous warranties and/or Connected Equip-
ment repair/replacement policies.

Tuotetiedot

Merkki: Panamax
Kategoria: Ei luokiteltu
Malli: MD2-TL

Tarvitsetko apua?

Jos tarvitset apua merkille Panamax MD2-TL esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Ei luokiteltu Panamax Käyttöohjeet

Panamax

Panamax MD2-AV Käyttöohje

11 Joulukuuta 2024
Panamax

Panamax MD2-TL Käyttöohje

11 Joulukuuta 2024
Panamax

Panamax MOD-DT4 Käyttöohje

11 Joulukuuta 2024
Panamax

Panamax MOD-AT8110 Käyttöohje

11 Joulukuuta 2024
Panamax

Panamax MOD-AT4 Käyttöohje

11 Joulukuuta 2024
Panamax

Panamax M4LT-EX Käyttöohje

11 Joulukuuta 2024
Panamax

Panamax MIP-20LT Käyttöohje

11 Joulukuuta 2024

Ei luokiteltu Käyttöohjeet

Viimeisimmät Ei luokiteltu Käyttöohjeet