Panasonic WH-UXZ12KE5 Käyttöohje

Panasonic Ilmastointi WH-UXZ12KE5

Lue alta 📖 käyttöohje suomeksi merkille Panasonic WH-UXZ12KE5 (56 sivua) kategoriassa Ilmastointi. Tämä opas oli hyödyllinen 4 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/56
Operating Instructions
Air-to-Water Hydromodule + Tank
Model No.
Indoor Unit
WH-ADC0912K6E5UK
Outdoor Unit
WH-UXZ09KE5
WH-UXZ12KE5
WH-UDZ12KE5
ENGLISH
Before operating the system, please read these
operating instructions thoroughly and keep them
for future reference.
WEB-ACXF55-35801-EN
2
Table of contents
System overview, Operating conditions ............................3
Safety precautions .......................................................4-16
Remote Controller buttons and display .....................17-18
Initialization .....................................................................19
Quick Menu ....................................................................20
How to use the Quick Menu ......................................21-25
Menus ........................................................................26-47
For user
1 Function setup ...................................................26-27
1.1 Weekly timer
1.2 Holiday timer
1.3 Quiet timer
1.4 Quiet priority
1.5 Room heater
1.6 Tank heater
1.7 Sterilization
1.8 DHW mode
2 System check ......................................................... 28
2.1 Energy monitor
2.2 System information
2.3 Error history
2.4 Compressor
2.5 Heater
3 Personal setup ...................................................29-30
3.1 Remote control No.
3.2 Touch sound
3.3 LCD contrast
3.4 Backlight
3.5 Backlight intensity
3.6 Clock format
3.7 Date & Time
3.8 Language
3.9 Unlock password
4 Service contact .......................................................30
4.1 Contact 1 / Contact 2
For installer
5 Installer setup > System setup ..........................31-41
5.1 Optional PCB connectivity
5.2 Zone & Sensor
5.3 Heater capacity
5.4 Anti freezing
5.5 DHW capacity
5.6 Buffer tank connection
5.7 Base pan heater
5.8 Alternative outdoor sensor
5.9 Bivalent connection
5.10 External SW
5.11 Solar connection
5.12 External error signal
5.13 Demand control
5.14 SG ready
5.15 External compressor SW
5.16 Circulation liquid
5.17 Heat-Cool SW
5.18 Force heater
5.19 Force defrost
5.20 Defrost signal
5.21 Pump owrate
5.22 DHW Defrost
5.23 Heating control
5.24 External meter
5.25 Electrical anode
6 Installer setup > Operation setup ......................42-46
6.1 Heat
6.2 Cool
6.3 Auto
6.4 Tank
7 Installer setup > Service setup ..........................46-47
7.1 Pump maximum speed
7.2 Pump down
7.3 Dry concrete
7.4 Service contact
8 Installer setup > Remote control setup ...................47
Cleaning instructions .................................................48-49
Troubleshooting .........................................................50-51
Information .................................................................52-53
Thank you for purchasing Panasonic product.
Installation Instructions attached.
Serial number and production year please refer to name plate.
Before use, make sure the system has been installed correctly by an
authorised dealer according to the given instructions.
Panasonic Air-to-Water is a split system, consisting of two units: indoor and outdoor units. The indoor unit consist of the hydromodule
and 200L sanitary water tank.
These operating instructions describe how to operate the system using the indoor and outdoor units.
As for the operation of other products such as radiator, external thermo controller, and under oor units, refer to the operating instructions
of each product.
System could be locked to operate in HEAT mode and disable COOL mode.
Some functions described in this manual may not be applicable to your system.
Ensure that incoming water is clean. When water tapped from a private well or spring water, it may be necessary to supplement with an
extra water lter.
Do avoid using water containing salt, acid, and other impurities which may corrode the tank and its component.
Consult your nearest authorised dealer for further information.
Operating conditions
HEATING (TANK) HEATING (CIRCUIT) *1, *2 COOLING (CIRCUIT)
Water outlet temperature (°C)
(Min. / Max.) - / 65*320 / 55 (Below Ambient -15 °C) *4
20 / 60 (Above Ambient -10 °C) *
45 / 20
Outdoor ambient temperature (°C)
(Min. / Max.)
-28 / 35 (WH-UXZ series)
-25 / 35 (WH-UDZ series) 10 / 43
When the outdoor temperature is out of the range in the table, the heating capacity will drop signi cantly and the outdoor unit may stop
operating for its protection.
The unit will restart automatically after the outdoor temperature returns to the speci ed range.
*1 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*2 Only displayed when COOL mode is unlocked (This means when COOL mode is available)
*3 Above 55 °C, only possible with backup heater operation.
*4 Between outdoor ambient -10 °C and -15 °C, the water outlet temperature gradually decreases from 60 °C to 55 °C.
System overview
Radiator
Shower
Fan Coil
Unit
Floor
Heating
Outdoor Unit
Solar Panel
Power Supply
Indoor Unit
(Structure of the unit may vary depending
on the model)
Remote Controller
Front Plate
Tap
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.
Note:
Not recommended to open the Front Plate.
(For authorised dealer/specialist use only)
Children aged from 3 to 8 years are only allowed to operate the tap connected to the water heater.
3
6
Safety precautions
CAUTION
Indoor unit and outdoor unit
Do not wash the indoor unit with
water, benzine, thinner or scouring
powder to avoid damage or corrosion
at the unit.
Do not install the unit close to
any combustibles or at bathroom.
Otherwise, it may cause electric
shock and/or re.
Do not touch the sharp
aluminium n, sharp parts
may cause injury.
Do not use the system during
sterilisation in order to prevent
scalding with hot water, or
overheating of shower.
Do not dismantle the unit for cleaning
purpose to avoid injury.
Do not step onto an unstable bench
when cleaning the unit to avoid injury.
Do not place a vase or water
container on the unit. Water may enter
the unit and degrade the insulation.
This may cause an electric shock.
Prevent water leakage by ensuring
drainage pipe is:
-Connected properly,
-Kept clear of gutters and containers,
or
-Not immersed in water
After a long period of use or use with
any combustible equipment, aerate
the room regularly.
After a long period of use, make
sure the installation rack does not
deteriorate to prevent the unit from
falling down.
Remote Controller
Do not wet the Remote Controller.
Failure to do so may result in electric
shock and/or re.
Do not press the buttons on the
Remote Controller using hard and
sharp objects. Failure to do so may
cause damage to the unit.
Do not wash the Remote Controller
using water, benzine, thinner or
scouring powder.
Do not inspect or maintain the
Remote Controller by yourself.
Consult an authorised dealer in order
to prevent personal injury caused by
incorrect operation.
8
Safety precautions
Any part of refrigerating circuit
(evaporators, air coolers, AHU,
condensers or liquid receivers) or
piping should not be located in the
proximity of heat sources, open
ames, operating gas appliance or
an operating electric heater.
The user/owner or their authorised
representative shall regularly check
the alarms, mechanical ventilation
and detectors, at least once a
year, where as required by national
regulations, to ensure their correct
functioning.
A logbook shall be maintained. The
results of these checks shall be
recorded in the logbook.
In case of ventilations in occupied
spaces shall be checked to con rm
no obstruction.
Before a new refrigerating system
is put into service, the person
responsible for placing the system
in operation should ensure that
trained and certi ed operating
personnel are instructed on the
basis of the instruction manual
about the construction, supervision,
operation and maintenance of the
refrigerating system, as well as the
safety measures to be observed,
and the properties and handling of
the refrigerant used.
The general requirement of trained
and certi ed personnel are indicated
as below:
a) Knowledge of legislation,
regulations and standards
relating to ammable refrigerants;
and,
b) Detailed knowledge of and
skills in handling ammable
refrigerants, personal protective
equipment, refrigerant leakage
prevention, handling of cylinders,
charging, leak detection,
recovery and disposal; and,
c) Able to understand and to apply in
practice the requirements in the
national legislation, regulations
and Standards; and,
d) Continuously undergo regular
and further training to maintain
this expertise.
e) Air-conditioner piping in the
occupied space shall be installed
in such a way to protect against
accidental damage in operation
and service.
f) Precautions shall be taken to
avoid excessive vibration or
pulsation to refrigerating piping.
g) Ensure protection devices,
refrigerating piping and ttings
are well protected against
adverse environmental effects
(such as the danger of water
collecting and freezing in relief
pipes or the accumulation of dirt
and debris).
h) Expansion and contraction of
long runs piping in refrigerating
systems shall be designed and
installed securely (mounted
and guarded) to minimize the
likelihood hydraulic shock
damaging the system.
i) Protect the refrigerating system
from accidental rupture due to
moving furniture or reconstruction
activities.
j) To ensure no leaking, eld-made
refrigerant joints indoors shall
be tightness tested. The test
method shall have a sensitivity
of 5 grams per year of refrigerant
or better under a pressure of at
least 0.25 times the maximum
allowable pressure (>1.04 MPa,
max 4.15 MPa). No leak shall be
detected.

Tuotetiedot

Merkki: Panasonic
Kategoria: Ilmastointi