Symmons SCOT SLC-6000 Käyttöohje
Lue alta 📖 käyttöohje suomeksi merkille Symmons SCOT SLC-6000 (18 sivua) kategoriassa Nosturi. Tämä opas oli hyödyllinen 2 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä
Sivu 1/18
SCOT®/Metering
Model Numbers
Metering Lavatory Faucet
Operation & Maintenance Manual
SLC-6000 Series
Metering lavatory faucet features 4" centerset mount,
3/8" copper supply tubes and temperature limit stop.
Vandal resistant 0.5 gpm (1.9 L/min) aerator limits water
ow to a maximum of 0.25 gpc (0.95 L/cyl) @ 60 psi
with a maximum 30 second closing time. Faucet
constructed from brass, plated in standard
polished chrome nish.
Specification
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations.
5 Years - for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Compliance
Modifications
Note: Append appropriate -sufx to model number.
SLC-6000
SCOT Metering Lavatory Faucet
-DP 8" deck plate
-G Grid drain
-IPS 1/2" male IPS connections
-ML Maxline thermostatic mixing valve for
temperature selection
-MV Mechanical mixing valve for temperature
selection
-OFG Offset grid strainer
-QC Quick close cartridge
-STE 8" supply tube extensions with
compression couplings
-ASME A112.18.1/CSA B125.1
-NSF/ANSI 61.9, NSF/ANSI 372
Dimensions
Measurements
A Ø 1-7/8", 48 mm
B 3-3/4", 95 mm
C
Deck Thickness Ref.
Min. 1/2", 13 mm
Max. 1", 25 mm
D 1-3/8", 35 mm
E 2-1/8", 54 mm
F(2x) Hole Size
Ø 1/2", 13 mm
GHole Size
Ø 1-1/4", 32 mm
H 11", 279 mm
I4", 102 mm
J5-3/4", 146 mm
K 1-1/2", 38 mm
L 2-1/4", 57 mm
M 1-1/8", 29 mm
N 3-5/8", 92 mm
O 3/8", 10 mm
JJ
AA
BB
HH
DD
CC EE
GG
II
KK
LL
MM
NN
FF
OO
TAPETAPE
Note: Dimensions subject to change without notice.
2
Replacement Parts
Item Description Part Number
A
B
Handle
Set Screw RL-290
B Set Screw LL-27
C Cycle Timing Washers (7) LL-28
D
E
F
Nut
Limit Stop Washer
Limit Stop Washer, Fixed
RL-268
G Upper Housing LL-3N
G1 LL-48Upper Housing O-rings (3)
G1
H3
H4
H5
H10
Upper Housing O-rings (3)
Cartridge O-ring
Cartridge O-ring
Guide O-ring
Piston Quadring
RL-272
HCartridge
Quick Closing Cartridge
LL-1A
LL-1B
H1
H6
Control Spindle Kit
Piston Assembly RL-266
H2 Thrust Washer LL-35
H6 Piston Assembly LT-4AA
H11 Piston Spring/Cylinder RL-267
J0.5 gpm Vandal Resistant
Aerator Kit with Key RL-292
K
L
Check
Spring RL-269
R
S
T
Mounting Bracket
Spacer
Mounting Nut
SPF-KIT
W Check/Screen Assembly LL-71B
X1, X2 8" Deck Plate Assembly RL-291
Parts Breakdown
B
A
C
D
E
F
G
H
I
JK
M
L
O
N
P
Q
R
S
T
U
V
W
DO NOT
REMOVE TAPE
X1
X2
CAP AND CARTRIDGE ASSEMBLY
G1
H6
H11
G
H
H3
H4
H5
H7
H8
H9
H10
H12
H13
H14
H1
H2
Notes: 1) Apply plumber tape to all threaded connections.
2) Compression nuts (U) and ferrules (V) not included.
3
Installation / Tools Required
Water lines MUST be thoroughly ushed BEFORE and AFTER installing the faucet to prevent foreign matter i.e.
copper chips, sand, stones, etc. from clogging and possibly damaging the sealing surfaces of the cartridge.
Notes: 1) Recommended minimum operating water supply pressure is 40 psi.
2) Supply stop valves must have 3/8" O.D. compression outlet.
1
2
U
V
W
1
2
3
3
1) Remove compression nuts (U) and
ferrules (V) from supply stops. Install
check/screen assemblies (W) to
supply stops.
2) Install faucet (I), threaded rods (M),
mounting gasket (Q), and 3/8" copper
tubing (P) to deck surface.
M
1
3
R
2
S
T
4
3) Place mounting brackets (R) and
spacers (S) onto threaded rods (M).
Secure hardware by tightening
mounting nuts (T) clockwise.
33
1
2
U
P
V
W
2
A
J
1
3
4
5) Remove aerator (J). Turn handle (A)
to full cold position. Open supply,
holding down handle for 10 seconds.
Rotate handle to full hot position,
open supply and repeat above
procedure. Hold down handle and
rotate from left to right to ush lines
completely.
6) After faucet has been operated
through a number of cycles, and sup-
ply water temperature is at desired
levels, adjustments to these features
can be made (see page 4).
I
M
Q
P
Important: DO NOT REMOVE tape
on copper tubing.
Adjustable Wrench Allen Wrench: 2.5 mm Phillips Head Screwdriver Plumber Tape
4) Connect compression nuts (U) and
ferrules (V) to copper tubing (P).
Carefully bend copper tubing (P) to
meet check/screen assemblies (W).
Attach compression nuts to check/
screen assemblies.
7) Optional 8" Deck Plate: Remove
threaded rods (M) from faucet (I).
Install two screws (X2) through
bottom of deck plate (X1) into
faucet (I). Install faucet and deck
plate to deck surface.
3
3
I
M
1 2
X2
X1
I
Tuotetiedot
Merkki: | Symmons |
Kategoria: | Nosturi |
Malli: | SCOT SLC-6000 |
Tarvitsetko apua?
Jos tarvitset apua merkille Symmons SCOT SLC-6000 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Nosturi Symmons Käyttöohjeet
17 Joulukuuta 2024
17 Joulukuuta 2024
17 Joulukuuta 2024
17 Joulukuuta 2024
Nosturi Käyttöohjeet
- Nosturi IKEA
- Nosturi Delta
- Nosturi Moen
- Nosturi Hansgrohe
- Nosturi Elba
- Nosturi Graff
- Nosturi Grohe
- Nosturi Livarno Lux
- Nosturi Zip
- Nosturi Oliveri
- Nosturi ProFlo
- Nosturi Rohl
- Nosturi Jacuzzi
Viimeisimmät Nosturi Käyttöohjeet
17 Joulukuuta 2024
17 Joulukuuta 2024
17 Joulukuuta 2024
17 Joulukuuta 2024
17 Joulukuuta 2024
17 Joulukuuta 2024
16 Joulukuuta 2024
16 Joulukuuta 2024
16 Joulukuuta 2024
14 Joulukuuta 2024