This product is intended for installation only by expert users. Please consult with a qualified technician for
installation. Improper installation may result in damage to your equipment.
1. Please carefully read the manual before beginning the installation process !
2. It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000.
3. DO NOT USE any kind of alcohol or alcohol derivatives with this reservoir or the acrylic tube may crack
and fail ! Do not clean it using alcohol either !
Pacific
RL120
Before Installation
Water Cooling Kit
Water Cooling Kit
Cautions: Make sure there's enough space when you start set up the LCS product
To ensure a clean loop,
flush and rinse your radiators
and water blocks with
distilled water before using.
Make sure the fittings are
screwed securely when
placing them onto
the radiator.
Attach the fans to the radiator
Attach fittings onto the pump
and reservoir
Attach the fittings to the inlet and
outlet of the waterblock.
Attach the waterblock onto the
motherboard by referring to the
enclosed manual.
Radiators Case Fan
Pump and Reservoir
Water Blocks
Installation Walkthrough (Example: Core V51)
Place the motherboard into the case. Position the radiator. Attach the pump and reservoir into
the chosen locations.
1

Cutting and Attaching the Tubing
Take out the cap from the fittings and place
the cap of the compression fitting over th e
tubing. Push the end of the tubing over the
barb; make sure the tu bing is a tight fit.
Slide the cap over the fitting and rotate it
clockwise until the tubing is sealed in place.
Connect the tubing and check all the
fittings are sealed. The loop orde r:
Pump Outlet > Water block
Connect the tubing and check all the
fittings are sealed. The loop orde r:
water black > radiator
Connect the tubing and check all the
fittings are sealed. The loop orde r:
radiator > Reservoir Inlet
3
3
2
2
1
1
4
Filling the System
Cautions:
1. Before filling the system, please make
sure that each fitting as well as unused
ports are completely sealed.
2. If there is any case of leaking,
immediately turn off the power and
clean the leak
3. If there's any related electronic parts
stained on liquid coolant, make sure to
completely clean and dry the
components. And then make sure they
all work well.
After switching off the po wer supply,
connect the PSU powe r cord and
product cables.
Use the refill bottle to fill coolant into the reservoir
Place your PSU outside of the case and attach it to
the pumps 4pin molex connector, turn on the power
of PSU and ma ke the rest of the system fills up.
Thermaltake recommends the following steps to be taken after completing your water loop setup
1. It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance
while preventing the entire cooling system – copper, brass, nickel, aluminum, and steel – from corrosion.
2. Fill the reservoir with coolant and cycle the power on and off several times while the pump pushing the coolant into the loop.
3. DO NOT let the pump run dry, when there is no liquid entering the pump turn off your power immediately
4. Fill the reservoir to the top as it will prevent air from going into the pump
5. If necessary tilt the system slightly from side to side to bleed the air out of the loop.
6. Place some paper towels under fittings and joining points to test for leaks.
7. Run the loop with the fill port open for about 24 hours to completely bleed the air out of the loop.
© 2015 Thermaltake Technology Co., Ltd. All Rights Reserved. www.thermaltake.com
Tuotetiedot
Merkki: | Thermaltake |
Kategoria: | Hardwarekoeling |
Malli: | Pacific RL120 |
Tarvitsetko apua?
Jos tarvitset apua merkille Thermaltake Pacific RL120 esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Hardwarekoeling Thermaltake Käyttöohjeet

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

1 Huhtikuuta 2025

30 Maaliskuuta 2025

29 Maaliskuuta 2025

29 Maaliskuuta 2025

29 Maaliskuuta 2025
Hardwarekoeling Käyttöohjeet
- Hardwarekoeling Apc
- Hardwarekoeling Gigabyte
- Hardwarekoeling Enermax
- Hardwarekoeling StarTech.com
- Hardwarekoeling Asus
- Hardwarekoeling Lian Li
- Hardwarekoeling Noctua
- Hardwarekoeling Zalman
- Hardwarekoeling Corsair
- Hardwarekoeling Daikin
- Hardwarekoeling Alphacool
- Hardwarekoeling DeepCool
- Hardwarekoeling MSI
- Hardwarekoeling SilverStone
- Hardwarekoeling Phanteks
- Hardwarekoeling EK Water Blocks
- Hardwarekoeling EVOLVEO
- Hardwarekoeling Middle Atlantic
- Hardwarekoeling Be Quiet!
- Hardwarekoeling Cryorig
- Hardwarekoeling Thermalright
- Hardwarekoeling Alpenföhn
- Hardwarekoeling Raijintek
- Hardwarekoeling Savio
- Hardwarekoeling AC Infinity
- Hardwarekoeling Antec
- Hardwarekoeling Chieftec
- Hardwarekoeling ALSEYE
- Hardwarekoeling Arctic Cooling
- Hardwarekoeling Scythe
Viimeisimmät Hardwarekoeling Käyttöohjeet

3 Huhtikuuta 2025

3 Huhtikuuta 2025

2 Huhtikuuta 2025

2 Huhtikuuta 2025

30 Maaliskuuta 2025

30 Maaliskuuta 2025

30 Maaliskuuta 2025

30 Maaliskuuta 2025

30 Maaliskuuta 2025

30 Maaliskuuta 2025