DESKTOP UPS
Installation & Operation
UPS1DT550-1N
UPS1DT750-1N
Product Overview
Operation Display
1. Inspection
The following items are inside the box: UPS Unit, User Manual
•Remove the UPS from its package and inspect it for damage that may have occurred during
shipping. If any damage is discovered, re-pack the unit and return it to the place of purchase.
2. Connect to Utility Power
•Connect AC power cord to utility power. Then, the UPS will start to charge inside battery. For best
result, charge the battery for 6 hours prior to initial use.
3. Plug in Equipment
•Battery back-up Outlets (5)
•Connect computer and monitor to the “Battery Backup” outlets. These outlets provide battery
backup, EMI ltering, line conditioning, and surge protection. Battery power is automatically
provided in case of power failure.
•Surge-Protected Outlets (5)
•Connect a printer, fax machine, or scanner to the “Surge-protected” outlets. These outlets do not
provide power during power failure.
CAUTION: NEVER connect a laser printer or scanner to the battery backup sockets of UPS. The
equipment may draw signicantly power to overload the UPS
4. Turn On/O the UPS
•To turn on the UPS unit, press the power switch lightly. Then, the LED or LCD will light up. To turn
o the UPS unit, press the power switch again. Then, display will shut o.
1. LCD display or LED indicators
(Please check LED or LCD
section for the details)
2. Power Switch
3. AC input
4. Battery backup
5. Surge-protected outlets
6. USB port
7. RJ11/RJ45 in/out
UPS Mode DescriptionLCD
UPS Power ON When UPS is powered on, it will
enter this mode for 4 seconds
AC Mode
LCD information will be displayed
in the following order when LCD is
touched.
1. Output voltage
2. Input voltage
3. Load Level
4. Battery capacity
Overload in AC mode
icon will ash
When overload occurs, alarm will
beep every 0.5 seconds
Battery Mode
When batter level is low.
icon will ash.
Alarm will beep every 10 seconds
and LCD information will be
displayed in the following order
when LCD is touched
1. Output voltage
2. Input voltage
3. Load Level
4. Battery capacity
Overload in battery mode
icon will ash
When overload occurs, alarm will
beep every 0.5 seconds
*NOTE: If backlight shuts o, you may activate it by touching the screen
LED Indicators UPS1DT550-1N only
UPS1DT750-1N only
LED Alarm UPS Status
Green OFF The mains is normal and
UPS is operating normally
Yellow Sounds every 10 seconds Power failure occurs and
UPS is on battery mode
Yellow Sounds every second Low Battery
Green OFF UPS is o
Red Continuously Sounds UPS fault
LED on LED o LED Flashing
5. Install software (Optional for advanced users)
For optimal computer system protection, install UPS monitoring software to fully congure the UPS
system. Please follow steps below to download and install monitoring software.
1. Go to the website http://www.V7-world.com/downloads
2. Select ViewPower software for your operating system to download the software.
3. Follow the on-screen instructions to install the software.
Safety Information
• This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble the unit. The unit
contains no user replaceable parts. Only factory service personnel may perform repairs.
• During the installation of this equipment it should be assured that the sum of the leakage currents of
the UPS and the connected loads does not exceed 3.5mA.
• Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle
may result in shock hazard as well as violate local electrical codes.
• In the event of an emergency, press the “OFF” button and disconnect the power cord from the AC
power supply to properly disable the UPS.
• Do not allow any liquids or any foreign object to enter the UPS.
• Do not place beverages or any other liquid-containing vessels on or near the unit.
• This unit intended for installation in a controlled environment (temperature controlled, indoor area
free of conductive contaminants). Avoid installing the UPS in locations where there is standing or
running water, or excessive humidity.
• Do not plug the UPS input into its own output.
• Do not attach an extension cord, power strip, or surge protector to the UPS.
• Do not attach non-computer-related items, such as medical equipment, life-support equipment,
microwave ovens, or vacuum cleaners to UPS.
• Do not dispose of batteries in a re as they may explode.
• A battery can present a risk of electrical shock and high short circuit current. The following
precautions should be observed when working on batteries:
1. Remove watches, rings, or other metal objects from the hands.
2. Use tools with insulated handles.
3. Wear rubber gloves and boots.
4. Do not lay tools or metal parts on top of batteries.
5. Disconnect charging source prior to connecting or disconnecting batteries terminal.
• Internal battery voltage is 12VDC Sealed, lead-acid, 6-cell battery.
• Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries
and the required precautions. Keep unauthorized personnel away from batteries.
• When replacing batteries, replace with the same number and type of sealed lead-acid battery.
• Do not open or mutilate the battery or batteries. Release electrolyte is harmful to the skin and eyes.
It may be toxic.
• Attention, hazardous through electric shock. Also with dis- connection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should be
therefore disconnected in the plus and minus pole at the connectors of the battery when mainte-
nance or service work inside the UPS is necessary.
• To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing
the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater
or furnaces.
• Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
Troubleshooting
Problem Possible Cause Solutions
Nothing is displayed on
the panel
The UPS is not on Press the power switch again to turn on
the UPS
Battery voltage is too low Charge the battery at least 6 hours
Battery fault Replace the battery
The UPS always on
battery mode Power cord is loose Re-plug the power cord
The UPS continuously
beeps
Please check the fault
code for the details Check the fault code table for details
Backup time too short
Battery voltage is too low Charge the battery at least 6 hours
Overload
Remove some unnecessary loads. Before
reconnecting equipment, please verify
that the load matches the UPS capability
specied in the specs.
Battery defect Replace the battery
* If any abnormal situations occur that are not listed above, please call for service immediately
Fault Codes
Fault Condition SolutionsLCD
Output short circuited
Disconnect short-
circuited loads and restart
the UPS
Overload fault
Disconnect all output
loads and restart the UPS
again
Overcharge Call for service
immediately
Bad or severely dis-
charged battery Replace battery
High output voltage fault Call for service
immediately
*If fault alarm occurs, please call for service immediately
08/16/2016
Tuotetiedot
Merkki: | V7 |
Kategoria: | UPS |
Malli: | UPS1DT550-1N |
Tarvitsetko apua?
Jos tarvitset apua merkille V7 UPS1DT550-1N esitä kysymys alla ja muut käyttäjät vastaavat sinulle
UPS V7 Käyttöohjeet
26 Lokakuuta 2024
26 Lokakuuta 2024
26 Lokakuuta 2024
UPS Käyttöohjeet
Viimeisimmät UPS Käyttöohjeet
22 Lokakuuta 2024
22 Lokakuuta 2024
22 Lokakuuta 2024