WHALE UF2214 Käyttöohje

Lue alta 📖 käyttöohje suomeksi merkille WHALE UF2214 (8 sivua) kategoriassa Ei luokiteltu. Tämä opas oli hyödyllinen 3 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/8
1
INSTALLATION AND
OPERATION MANUAL
Whale®Pump Accumulator Kit
*The B’ suffix indicates that a bulk code is available
Model Number Description
Accumulator Kits (2ltr Tanks)
UF2214 3.0 GPM (11.5 ltrs), 12 V d.c., 2 bar (30 psi), 15mm Quick Connect Connections
UF2215 3.0 GPM (11.5 ltrs), 12 V d.c., 3 bar (45 psi), 15mm Quick Connect Connections
UF2224 3.0 GPM (11.5 ltrs), 24 V d.c., 2 bar (30 psi), 15mm Quick Connect Connections
UF2225 3.0 GPM (11.5 ltrs), 24 V d.c., 3 bar (45 psi), 15mm Quick Connect Connections
2
INSTALLATION AND OPERATION MANUAL
Whale®Accumulator Kit
Thank you for purchasing this Whale® product. For over 60 years, Whale® has led the way in the design and manufacture of freshwater
and waste systems including: pumps, plumbing, faucets and showers for low voltage applications. The company and its products have built
a reputation for quality, reliability and innovation backed up by excellent customer service.
For information on our full range of products visit www.whalepumps.com
1. LIST OF CONTENTS 7. WARNINGS 13. WINTERIZING
2. SPECIFICATION 8. PARTS LIST 14. SERVICE SUPPORT DETAILS
3. PRINCIPLES OF OPERATION 9. OPTIONAL EXTRAS 15. TROUBLE SHOOTING
4. TO THE USER 10. INSTALLATION 16. PATENTS AND TRADEMARKS
5. TO THE FITTER 11. INSTRUCTIONS FOR USE 17. WARRANTY STATEMENT
6. APPLICATION 12. MAINTENANCE 18. EU DECLARATION OF CONFORMITY,
STANDARDS AND APPROVALS
List of Diagrams
Fig. 1 Marine Typical Installation Fig. 3 Connecting the Strainer Fig 5 Wiring Diagram
Fig. 2 Pump Orientation Fig. 4 Dual Tank System
The Whale Accumulator Kit is designed for marine vessels for reliable and smooth consistent flow. The pump accumulator kit provides
smooth flow from the system with reduced pump cycling. Please refer to the specifications (section 2) for the model range.
Please read the following carefully before installation. WARNING: Please note that incorrect installation may invalidate the warranty.
Check that the product is suitable for the intended application, follow these installation instructions and ensure all relevant personnel read
the points listed below. Also ensure that these operating instructions are passed on to the end user.
The Whale® Accumulator Kit is designed for installation in recreational vessels for saltwater or freshwater use, with 12 V d.c. or 24 V d.c.
electrical supply only. If it is intended for use for any other purpose or with any other liquid, it is the user's responsibility to ensure that the
pump is suitable for the intended use and, in particular, that the materials are fully compatible with the liquids to be used.
1. This pump is designed for supplying water in a marine vessel. If it is intended for use for any other purpose it is the
user's responsibility to ensure that the pump is suitable for the intended use.
2. Not suitable for pumping flammable liquids, diesel, chemicals etc. Only suitable for freshwater.
3. A Whalstrainer fitted on the inlet side of the pump to prevent any dirt/debris entering the pump must be
4. With all applications, it is important that a system of safe working practice is applied to installation, use and
maintenance. Ensure the electric supply is turned off and water system is drained before installation. In order to
securely fasten the unit, ensure that the mounting surface is a minimum thickness of 19mm (¾") when fitted.
5. NOTE: Do not Must bescrew directly to the hull. mounted on a bulkhead or additional board.
6. Pump CAUTION: not intended for continuous use.
7. WARNING: must comply Fire hazard. Wiring with applicable electrical standards and include a properly sized fuse or circuit
breaker. Improper wiring can cause a fire resulting in injury or death. Switch off the power while making connections. Suggested
wiring information is given as guidance only. For full information, refer to the USCG, ABYC and ISO regulations for marine
applications and wiring gauges, connectors and fuse protection.
All Whale® Accumulator Kits Qty 1 Whale® Accumulator Kit Qty 1 Whale® Strainer
UF2214 / UF2224 only Qty 1 Equal Straight Qty 1 Inline Check Valve
AK1316 Replacement Head Kit WF1530 Whale Aquasource Clear Water Filter 15mm
2. SPECIFICATION
1. LIST OF CONTENTS
Product Code UF2214 (B) UF2215 (B) UF2224 (B) UF2225 (B)
Pressure Pump UF1214 UF1215 UF1224 UF1225
Accumulator Tank Size 2 ltrs (0.53 US Gals)
Open Flow Rate (per minute) 11.5 ltrs (3.0 US Gals)
Voltage 12 V d.c. 24 V d.c.
Recommended Fuse Rating 10 Amp Automotive 5 Amp Automotive
Cut Out Pressure 2 bar (30psi) 3 bar (45psi) 2 bar (30psi) 3 bar (45psi)
Weight 3.9kg (8.59lbs)
Factory Pre-charge 1.5 bar (22 psi) 2.2 bar (32psi) 1.5 bar (22 psi) 2.2 bar (32psi)
Inlet and Outlet Size Whale® Quick Connect 15mm Female Connections
Materials in contact with Liquid Glass-filled Polypropylene, Santoprene, Nitrile®, Stainless Steel, Butyl
Minimum Wire Size 2.5mm² (13 AWG)
Maximum Head 20m (66ft) 30m (99ft) 20m (66ft) 30m (99ft)
Maximum LIft 3m (10ft)
3. PRINCIPLES OF OPERATION
4. TO THE USER
5. TO THE FITTER
6. APPLICATION
7. WARNINGS
8. PARTS LIST
9. OPTIONAL EXTRAS
3
NOTE - Always disconnect power sources before
installing. Incorrect installation will invalidate
warranty.
The Whale® Accumulator Tank Kit is designed for
use in a marine application only.
10.i Mounting Instructions
Step 1 Locate in a dry position with adequate ventilation and no more than 3m (9ft)
above the water tank. In normal use, ensure the pump cannot be submerged in
water.
Step 2 Ensure the accumulator kit is mounted free of obstacles and accessible for
maintenance.
Step 3 The pump can be mounted horizontally or vertically. We recommend that the
pump head is mounted below motor level (Figure 2). For advice on your specific
installation, please contact Whale® support.
Step 4 There are 4 mounting holes in the accumulator tank base. Use 4 self-tapping
stainless steel screws and washers to fasten base to solid surface and support
the accumulator securely (Figure 2).
10.ii Plumbing
Check pump flow direction (as indicated on pump body) and ensure
that a strainer (supplied with retail pump) is attached to the pump head
inlet (Figure 3).
Never use pipe sealant or sealing tapes on threaded adaptors, as these
may enter the pump and cause failure.
Ensure a double click into Quick Connect connections (Figure 3).
Please note: Some installations may require a dual tank system to ensure flow
consistency. Dual tanks are required in systems where there are more outlets working
simultaneously.
In a dual tank system, the two accumulator kits plumbed into the same system onmust be
the outlet side but maintain inlet source through plumbing - this will allowdifferent
sufficient water to enter each pump.
In a dual tank system, the master tank will turn on with every use. When more outlets are
opened, the second accumulator kit will begin to operate at intervals which will ensure
consistent smooth flow throughout your system.
Twist
Deck
Shower
Swan Neck
Faucet
Elite
Faucet
Elegance
Combination
Mixer
Thermostatic
Mixer
Expansion
Vessel
Water Tank
Accumulator
Non Return
Valve
Quick
Connect
Elbow
Quick Connect
Equal Tee
Shut
off
valve
Stem Shut
off Valve
Fig. 1a Typical Installation in a
Marine System
(Illustration for guidance purposes only)
Fig 2 - Recommended Kit Mounting Orientation
Fig 3 - Attaching The Strainer
Secure
the pump
Double click for a
secure connection
10. INSTALLATION
Fig 4 - Dual Tank System
Master Kit - UF2215 or UF2225
Secondary Kit - UF2214 or UF2224
Dual System Master Kit Secondary Kit
12 V d.c. System UF2215 UF2214
24 V d.c. System UF2225 UF2224
Non-return Valve

Tuotetiedot

Merkki: WHALE
Kategoria: Ei luokiteltu
Malli: UF2214

Tarvitsetko apua?

Jos tarvitset apua merkille WHALE UF2214 esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Ei luokiteltu WHALE Käyttöohjeet

Ei luokiteltu Käyttöohjeet

Viimeisimmät Ei luokiteltu Käyttöohjeet