Winland Temp Alert TA-1 Käyttöohje

Winland Ilmankostutin Temp Alert TA-1

Lue alta 📖 käyttöohje suomeksi merkille Winland Temp Alert TA-1 (4 sivua) kategoriassa Ilmankostutin. Tämä opas oli hyödyllinen 3 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/4
Powerless Temperature Monitoring with Single Output
SPECIFICATIONS
Power Requirement No power required to operate.
Operating Temperature 50 to 130° F (10 to 54° C); non-condensing environments only.Alarm Use:
Alarm contacts may not function outside of this range.
-30 to 130° F (-34 to 54° C); non-condensing environments only.Display Use:
Low Limit Adjust Range -30 to 120° F (-34 to 49° C)
High Limit Adjust Range -20 to 130° F (-29 to 54° C)
Temp Accuracy ±3°F (±1.7° C)
Temp Response Time TC = 14 minutes
Temp Sensing Element Bimetallic Coil
Outputs Gold plated N.O. dry contacts (Not for high voltage use.)
Contact Output Rating 50mA @ 12VDC
Weight 6.5 oz (.18 kg)
Dimensions 6.25 x 3.75 x 2” (15.9 x 9.5 x 5.1 cm)
Material ABS
Mounting Key slot
CONTENTS
This package contains:
One (1) TA-1
Two (2) mounting screws and two (2) wall anchors
Mounting template (inside this Instruction Guide)
One (1) Installation/Operating Instructions Guide
TA-1
© 2012 Winland Electronics, Inc.
D-011-0113 Rev B (08/2012)
Tech Support 8:00am - 5:00pm Central Time
(800) 635-4269 • +1-507-625-7231 P
www.winland.com
INTRODUCTION
The Temp˚Alert ® has been designed for reliable monitoring of non-condensing (indoor only) environment
areas where high and low temperature limits are critical.
Select an acceptable temperature range by setting the adjustable high and low limit arms. If the monitored are
temperature either rises or falls to the limit arms, the temperature indicator will contact one of the limit arms.
This completes the circuit and provides you with a dry contact alarm signal. The TA-1 contacts are normally
open (N.O.) dry contacts rated at 50mA at 12 VDC . This output can be used to activate alarm systems, telephone
dialers, or other remote warning devices. Temp˚Alert ® is the ideal addition for any security system.
LOCATION
In specifying the location and number of TA-1s to install consider room size, effectiveness of the ventilation
system, and critical monitoring areas. If the building already has an energy management system, an easy rule
of thumb to follow is to install a TA-1 near each thermostat. It should be mounted on a wall or other vertical
surface in the area where temperature is to be monitored. Make sure it is well clear of windows, doors, or heat
sources that could cause an inaccurate reading of air temperature. When protecting a building against freeze
damage, always install at least one Temp˚Alert ® on every level of the home or business.
INSTALLATION
Items needed:
· Standard screwdriver · 11/32” wrench · 22-18 AWG twisted pair
STEP 1 – A TA-1 M STTACH TO OUNTING URFACE
Position the mounting template in the desired location and mark the mounting holes. Depending on the type
of surface you are mounting to, you may need to predrill holes to accept the mounting screws alone, or use the
plastic anchors and mounting screws. Drive the screws into the mounting surface, allowing approximately 3/16”
between the screw head and the mounting surface. (See Mounting Template below.) Engage the key slots on
the back of the TA-1 case with the screw heads and press down.
To insure proper operation, test weekly.
M TOUNTING EMPLATE
STEP 2 – M W CAKING THE IRING ONNECTIONS
Connect the TA-1 to your warning device by attaching a 22-18 AWG twisted pair cable from (2) front mounted
terminals of the TA-1 to an open zone on your alarm panel, telephone dialer, wireless transmitter, etc. See
Figure 1.
STEP 3 – S H L S PETTING THE IGH AND OW ET OINTS
Each limit arm is controlled by an adjustment screw. To set a limit arm, slightly loosen the appropriate locknut
(turn counter clockwise) with a 11/32” wrench (See Figure 2). Next, use a screwdriver to set the limit arm to the
desired temperature limit (See Figure 3). Once the arm is in the proper setting locations, retighten the locknut
(turn clockwise) (See Figure 4). Avoid over tightening of the locknut. Repeat this process until both temperature
limits have been set. Make sure to retighten the locknut when temp limits have been set. The TA-1 will not
function properly if the locknut is not retightened.
®
Low Limit Arm
Low Limit
Adjustment
High Limit
Arm
High Limit
Adjustment
Temperature Indicator
1 2 3
4 5 6
7 8 9
0
Panel / Dialer / Transmitter
Figure 1
O TPERATION AND ESTING ROCEDURES P
To manually activate the TA-1 for testing, loosen the locknut of one limit arm and use a screwdriver to move
the limit arm toward the temperature indicator until it makes contact and temporarily tighten the locknut. If
installed correctly, this test procedure should activate the warning device to which the TA-1 is connected. After
testing, loosen the locknut, return the limit arm to its original set point and tighten the locknut. The same test
procedure should also be repeated with the second limit arm to verify proper operation.
®
®
®
Figure 2 Figure 3 Figure 4
I :MPORTANT
Do not use the TA-1 in a cooler or freezer. Frost buildup and moisture
can cause the unit to malfunction. For cooler & freezer applications,
use an EnviroAlert® device with a remote probe.

Tuotetiedot

Merkki: Winland
Kategoria: Ilmankostutin
Malli: Temp Alert TA-1

Tarvitsetko apua?

Jos tarvitset apua merkille Winland Temp Alert TA-1 esitä kysymys alla ja muut käyttäjät vastaavat sinulle