1. Prepare the ceiling tile grid for a 1’ x 2’ or
2’ x 2’ installation.
2. Determine the correct mounting height of
the access point (AP) mounting plate.
Use the included standoffs for APs with
integrated antennas (Figure 1). For AP
installations using rubber duck antennas,
do not use the mounting plate standoffs
(Figure 2).
3. Secure the AP mounting plate on the
enclosure mounting plate (Figure 3) with
the appropriate hardware. For most
Cisco APs, the mounting holes are
already pre drilled into the mounting plate. -
For all other APs, use self tapping -
screws.
4. Install the desired door insert.
5. Place the enclosure into the ceiling tile
grid. Pull power and Ethernet
connections through the provided cord
grips as needed.
6. If desired, install the included ceiling tile
insert for a 2’ x 2’ installation.
7. Secure the enclosure to the ceiling
structure if required by local building
codes.
8. Connect the power and Ethernet to the
AP as recommended by the AP
manufacturer.
9. Install the AP onto the mounting plate.
10. Close the enclosure door and turn the
locking mechanism to lock the enclosure
door (Figure 4).
Figure 1
Figure 3
Figure 2
Figure 4
1. The ceiling tile enclosure has four holes in
the back for easy mounting (Figure 1).
2. There are two eyebolts provided along
with nuts, washers and lock washers to
secure the enclosure to your ceiling
structure based on your local building
codes (Figure 2).
3. Secure a nut, lock washer and washer to
the top of the eye bolt (Figure 3) Insert
into the hole of your choice on the back of
the enclosure.
4. Inside the enclosure, secure the bottom of
the eye bolt with a washer, lock washer
and nut (Figure 4).
5. Repeat the first four steps for the second
eye bolt to be placed in the hole of your
choice at the back of the enclosure.
6. Once eye bolts are installed, secure the
enclosure to the ceiling with wire or cable
through the eye bolts to the ceiling
structure per local building codes.
Figure 1
Figure 3
Figure 2
Figure 4