Jotul F 100 Nordic QT Käyttöohje

Jotul Liesi F 100 Nordic QT

Lue alta 📖 käyttöohje suomeksi merkille Jotul F 100 Nordic QT (24 sivua) kategoriassa Liesi. Tämä opas oli hyödyllinen 2 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/24
Jøtul F 100 Nordic QT
Woodburning Stove
Installation and Operating Instructions
for the United States and Canada
tul F 100
Nordic QT
The Jøtul F Nordic QT non-catalytic 100
stove is listed to burn solid wood only.
Do not burn any other fuels.
Read this entire manual before you install
and use this appliance.
Save these instructions for future
reference and make them available to
anyone using or servicing the stove.
This wood heater requires periodic
inspection and repair for proper
operation. See this manual for specific
maintenance information. It is against
federal regulations to operate this wood
heater in a manner inconsistent with the
operating instructions in this owner’s
manual.
Télécharger la version française de ce manuel à ladresse
www. jotul.ca.
2
139678 06 100-R F 1/20
Table of Contents
General Information
Standards 2 .....................................................................................
Combustion Specifications 3 ......................................................
Codes 3 .............................................................................................
Safety Notices 4 ..............................................................................
1.0 Installation
Flue Collar Installation 4 ...............................................................
Ash Lip 5 ...........................................................................................
Door Knob 5 ....................................................................................
Chimney Connector 5 ....................................................................
Flue Collar Heat Shield 5 ..............................................................
2.0 Chimney Requirements
Masonry Chimneys 6 ....................................................................
Prefabricated Chimneys.............................................................6
Chimney Height 6 ...........................................................................
Wall Pass-Throughs 7 .....................................................................
3.0 Connecting to the Chimney
Masonry Chimney 8 ......................................................................
Hearthmount / Fireplaces 8 .........................................................
Prefabricated Chimneys.............................................................9
4.0 Clearances to Combustibles
Floor Protection 9 ...........................................................................
Clearances to Walls and Ceilings 10 .............................................
Alcove Installation 10 .......................................................................
Clearance Chart 12 ...........................................................................
Clearance Diagrams 13 ....................................................................
5.0 Operation
Combustion Efficiency 14 ..............................................................
CO Emissions 14 ................................................................................
Wood Fuel and Performance 14 ....................................................
Break-in Procedure 15 .....................................................................
Starting / Maintaining the Fire 16 ................................................
Formation of Creosote 16 ...............................................................
Adding Fuel 16 ..................................................................................
6.0 Maintenance
Ash Removal 17 .................................................................................
Glass Care 17 ......................................................................................
Chimney 17 ........................................................................................
7.0 General Maintenance
Enamel 18 ..........................................................................................
Annual Inspection 18 ......................................................................
Gaskets 18 ...........................................................................................
8.0 Accessories
Stove-top Thermometer ............................................................18
Flue Collar Heat Shield 18 ...............................................................
9.0 Warranty ..........................................................................19
10.0 Illustrated Parts List ............................................... 22-23
Standards
The Jøtul F Nordic QT solid fuel heater has been 100
tested and listed to :
U.S. Standards: ANSI/UL 737 and ANSI/UL 1482.
Canadian Standards:
CAN/ULC-S627-M and CAN/ULC-S628-M00 93
Certified Safety Tests performed by:
Intertek Testing Services, Middleton,
Wisconsin U.S.A.
Manufactured by:
Jøtul North America, Inc.
55 Hutcherson Drive
Gorham, Maine 04038, USA
and
Jøtul AS, P.O. Box 1411, Fredrikstad, Norway
A French language version of fhis manual is available to
download at www. jotul. ca.
Télécharger la version française de ce manuel à l’adresse
www. jotul.ca.
NOTE: It is normal for a new, painted stove to emit
odor and smoke during initial fires, depending
upon temperatures over time. This is caused by
the curing of the high temperature paint and
manufactureing materials. This condition can be
alleviated by opening a window or door to provide
additional ventilation.
WARNING !
THIS WOOD HEATER HAS A MANUFACTURER-
SET MINIMUM LOW BURN RATE THAT MUST
NOT BE ALTERED. IT IS AGAINST FEDERAL
REGULATIONS TO ALTER THIS SETTING
OR OTHERWISE OPERATE THIS WOOD
HEATER IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL.
This heater meets the 2015 U.S.
Environmental Protection Agency’s
emission limits for wood heaters
manufactured after May 15, 2015.
This heater may not be sold
after May 15, 2020.
THE JØTUL F WOOD HEATER IS NOT 100
APPROVED FOR USE IN MOBILE HOMES.
3
139678-R06 F 100 1/20
Check Building Codes
When installing, operating and maintaining your
Jøtul F Nordic QT woodstove, follow the guidelines 100
presented in these instructions, and make them avail-
able to anyone using or servicing the stove.
Your city, town, county or province may require a building
permit to install a solid fuel burning appliance.
In the U.S., the National Fire Protection Associations
Code, NFPA 211, Standards for Chimneys, Fireplaces, Vents
and Solid Fuel Burning Appliances, or similar regulations,
may apply to the installation of a solid fuel burning
appliance in your area.
In Canada, the guideline is established by the CSA
Standard, CAN/CSA-B365-M93, Installation Code for
Solid-Fuel-Burning Appliances and Equipment.
Always consult your local building inspector or authority
having jurisdiction to determine what regulations apply
in your area.
22 1/2
570 mm
20 3/4”
527 mm
18 1/2
469 mm
Rear Exit
Centerline
13 1/2
347 mm
17 1/2
445 mm
24”
610 mm
Combustion Specifications
Jøtul F Nordic QT100
Heat Output Range:1 7,700 to 27,400 BTU/hr.
Max. Heat Output: 35,000 BTU/hr.
Heating Capacity:2 Up to 800 sq. ft.
Maximum Burn Time:2 Up to 6 hours
EPA Efficiency:3 HHV: 72.85% LHV: 78.75%
CO Emissions:4 113.99 g/hr
Pariculate Emissions:5 3.0 g/hr
Fuel: Up to 16” Logs (406 mm)
.
1 results are determined during specific Heat Output Range
emissions tests established by the EPA.
The Maximum Heat Output value is representative of a more
frequent re-fueling cycle than specified in the EPA High Heat
Output test method.
2 Heating Capacity and Maximum Burn Time will vary depend-
ing on design of home, climate, wood type and operation
3 EPA Validated Efficiency:
High Heat Value and Low Heat Value are obtained per CSA
B415.1-10 test method. HHV calculation encompasses all
products of combustion, including H2O condensation. LHV
calculation includes H2O in its vapor state. Simply put, HHV
assumes all the water component is in a liquid state (con-
densed) at the end of combustion and that heat recovered
from condensation can be put to use.
4 rate results from Test Method Carbon Monoxide Emissions
CSA B415.1-10.
5. rate is obtained using EPA Test Method Particulate Emissions
28-5H.

Tuotetiedot

Merkki: Jotul
Kategoria: Liesi
Malli: F 100 Nordic QT

Tarvitsetko apua?

Jos tarvitset apua merkille Jotul F 100 Nordic QT esitä kysymys alla ja muut käyttäjät vastaavat sinulle