Jotul GF 400 DV Sebago Käyttöohje

Jotul Liesi GF 400 DV Sebago

Lue alta 📖 käyttöohje suomeksi merkille Jotul GF 400 DV Sebago (32 sivua) kategoriassa Liesi. Tämä opas oli hyödyllinen 2 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä

Sivu 1/32
Installation and
Operation Instructions
Jøtul GF 400 DV Ver. 2
Sebago
Direct Vent Gas Stove
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall
be installed in the same room as the
appliance.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or loss of life.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or
mobile home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is
supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.











137750_Rev_22 GF 400 DV 01/22
We recommend that
our gas products be
installed and serviced by
professionals who are
certified in the U.S. by
the National Fireplace
Institute® (NFI) as NFI
Gas Specialists.
Installation Requirements
for the Commonwealth of
Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GASFITTER WHEN
INSTALLED IN THE COMMONWEALTH OF
MASSACHUSETTS.
1. If there is not one already present,
on each floor level where there are
bedroom(s), a carbon monoxide
detector and alarm shall be placed in
the living area outside the bedroom(s).
The carbon monoxide detector shall
comply with NFPA 720 (2005 Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses
the appliance or equipment;
b) Be either hard-wired or battery
powered or both; and
c) Shall comply with NFPA 720 (2002
Edition).
3. A Product-approved vent terminal
must be used, and if applicable, a
Product-approved air intake must
be used. Installation shall be in strict
compliance with the manufacturer’s
instructions. A copy of the installation
instructions must remain with
the appliance or equipment at the
completion of the installation.
THIS OWNER’S MANUAL PROVIDES INFORMATION TO
ENSURE SAFE INSTALLATION AND EFFICIENT, DEPENDABLE
OPERATION OF YOUR FIREPLACE INSERT. PLEASE READ
THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM
AVAILABLE TO ANYONE USING OR SERVICING THIS GAS
INSERT.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION
OF THIS APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION WILL VOID THE WARRANTY,
CERTIFICATION AND LISTING OF THIS APPLIANCE.
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED SERVICE AGENCY.
Suggested Tools for
Installation and Service
External regulator (for Propane only)
Piping which complies with local code
Manual shut-off valve -
T-Handle required in Massachusetts
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10 mm open end wrench
1/2”, 7/16” open end wrench
Phillips head screwdriver
Flat head screwdriver
1/4 nut driver
Gloves
Safety glasses
Torx T-20 screwdriver
Tin snips
PLEASE NOTE:
It is normal for smoke and odor to occur during
the initial stages of operation, depending upon
temperatures generated over time. This curing”
condition can be alleviated by promoting fresh
air circulation within the immediate vicinity of
the appliance.
61.53%
Jøtul GF 400 DV
Based on CSA P.4.1-15
3
137750_Rev_V GF 400 DV 10/21
Table of Contents
Service Tools .............................................2
Specifications 4 ............................................
General Information 5 ................................
Safety Information 6 ..................................
Installation Requirements
Location 6 ................................................
Hearth Protection 6 ...............................
Clearances 7 .............................................
Mantel & Trim 7 ......................................
Alcove 7 ....................................................
Vent Requirements 8 ..................................
Adding Restriction 8 ...............................
Vertical Termination 9 ...........................
Co-linear Termination 12 ....................
Coaxial Chimney Conversion 13 ......
Horizontal Termination 14 ....................
Vent Terminal Clearances 15 ................
Mobile Home Installation 16 ....................
Fuel Conversion 16 .......................................
Gas Connection 18 .......................................
Gas Pressure 19 ............................................
High Altitude Adjustment 19 ...................
Air Shutter Adjustment 20 ......................
Wall Thermostat .................................... 20
Remote Control 20 ......................................
Log Set Installation 21 ................................
System Check 22 ..........................................
Operation 23 .................................................
Maintenance 24 ...........................................
Glass Replacement 24 .............................
Optional Blower Installation 25 ..............
Optional Brick Kit Installation ............27
Illustrated Parts Breakdown 28 ................
Replacement Parts List 29 .........................
Warranty Statement 30 ............................
Lighting Instructions 31 ..............................
Jøtul GF DV Sebago 400
Direct Vent Gas Heater
Manufactured and Distributed by:
Jøtul AS
Fredrikstad, Norway
Jøtul North America
55 Hutcherson Dr.
Gorham, Maine 04038-2634
Test Standards
This appliance complies with National Safety standards
and is tested and listed by Intertek Testing Services of
Middleton, Wisconsin to ANSI Z21.88-2016,• CSA 2.33-2016
and CAN/CGA 2.17-M91.
DO NOT ATTEMPT TO ALTER OR MODIFY THE
CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS.
ANY MODIFICATION OR ALTERATION WILL VOID THE
WARRANTY, CERTIFICATION AND LISTING OF THIS
APPLIANCE.
Your stove has a unique serial number stamped on the
rating plate which is hung on the back. Please record
the serial number in the space below. You may also wish
to attach your purchase receipt to this page for future
reference.
MODEL NAME: tul GF DV Sebago Gas Stove400
SERIAL NUMBER:_______________________________
DATE OF PURCHASE:____________________________
AUTHORIZED DEALER:__________________________
ADDRESS ___________________________________
PHONE: ____________________________________
INSTALLER:__________________________________
FUEL TYPE:____________________________________
FUEL CONVERSION: NO _______ YES_____
NOTES:________________________________________
______________________________________________
______________________________________________

Tuotetiedot

Merkki: Jotul
Kategoria: Liesi
Malli: GF 400 DV Sebago

Tarvitsetko apua?

Jos tarvitset apua merkille Jotul GF 400 DV Sebago esitä kysymys alla ja muut käyttäjät vastaavat sinulle