Jotul GF 300 DV Allagash Käyttöohje
Lue alta 📖 käyttöohje suomeksi merkille Jotul GF 300 DV Allagash (32 sivua) kategoriassa Liesi. Tämä opas oli hyödyllinen 4 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä
Sivu 1/32
Jøtul GF 300 DV
Allagash
Direct Vent Gas Stove
Steel Burner
v.2
Installation and
Operation Instructions
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
– Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
– In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall
be installed in the same room as the
appliance.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or loss of life.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or
mobile home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is
supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Conforms to ANSI Z21.88-2019 • CSA 2.33-2019,
and CAN/CGA 2.17-M91.
For stoves Serial Number 42005149 and above
137775-Rev 28 GF 300 DV 01/22
We recommend that
our gas products be
installed and serviced by
professionals who are
certified in the U.S. by
the National Fireplace
Institute® (NFI) as NFI Gas
Specialists.
65.75%
Jøtul GF 300 DV MV
THIS OWNER’S MANUAL PROVIDES INFORMATION TO
ENSURE SAFE INSTALLATION AND EFFICIENT, DEPENDABLE
OPERATION OF YOUR FIREPLACE INSERT. PLEASE READ
THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM
AVAILABLE TO ANYONE USING OR SERVICING THIS GAS
INSERT.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION
OF THIS APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION WILL VOID THE WARRANTY,
CERTIFICATION AND LISTING OF THIS APPLIANCE.
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED SERVICE AGENCY.
Suggested Tools for
Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shut-off valve -
T-Handle required in Massachusetts
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10 mm open end wrench
• 1/2”, 7/16” open end wrench
• Phillips head screwdriver
• Flat head screwdriver
• 1/4” nut driver
• Gloves
• Safety glasses
• Torx T-20 screwdriver
• Tin snips
Installation Requirements for the
Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GAS-FITTER WHEN
INSTALLED IN THE COMMONWEALTH OF
MASSACHUSETTS.
1. If there is not one already present,
on each floor level where there are
bedroom(s), a carbon monoxide detector
and alarm shall be placed in the living
area outside the bedroom(s). The carbon
monoxide detector shall comply with
NFPA 720 (2005 Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses the
appliance or equipment;
b) Be either hard-wired or battery
powered or both; and
c) Shall comply with NFPA 720 (2002
Edition).
3. A Product-approved vent terminal must
be used, and if applicable, a Product-
approved air intake must be used.
Installation shall be in strict compliance
with the manufacturer’s instructions. A
copy of the installation instructions must
remain with the appliance or equipment
at the completion of the installation.
Based on CSA P.4.1-15
PLEASE NOTE:
Initial Break-in
It is normal for smoke and odor to occur during the initial
stages of operation, depending upon temperatures
generated over time. This “curing” condition can be
alleviated by promoting fresh air circulation within the
immediate vicinity of the appliance.
Operation Sound
Please be aware that cast iron and steel components
expand and contract with temperature fluctuations that
are often accompanied by “creaking” or “pinging” sounds.
This is the result of natural
thermal activity.
The optional blower fan
will also generate a slight
hum at the low setting and
progressively increase with the
velocity of forced air.
3
137775-Rev 28 GF 300 DV 01/22
Table of Contents
Service Tools .............................................2
Specifications 4 ............................................
General Information 5 ................................
Safety Information 6 ..................................
Installation Requirements
Location 6 ................................................
Hearth Protection 6 ...............................
Clearances 7 .............................................
Mantel & Trim 7 ......................................
Alcove 7 ....................................................
Vent Requirements 8 ..................................
Adding Restriction 8 ...............................
Vertical Termination 9 ...........................
Co-linear Termination 12 ....................
Coaxial Chimney Conversion 13 .......
Horizontal Termination 14 ....................
Vent Terminal Clearances 15 ................
Mobile Home Installation 16 ....................
Fuel Conversion 16 .......................................
Gas Connection 18 .......................................
Gas Pressure 19 ............................................
High Altitude Adjustment 19 ...................
Air Shutter Adjustment 20 ......................
Wall Thermostat .................................... 20
Remote Control 20 ......................................
Log Set Installation 21 ................................
System Check 22 ..........................................
Operation 23 .................................................
Maintenance 24 ...........................................
Glass Replacement 24 .............................
Optional Blower Installation 25 ..............
Optional Brick Kit Installation ............27
Illustrated Parts Breakdown 28 ................
Replacement Parts List 29 .........................
Warranty Statement 30 .............................
Lighting Instructions 31 ..............................
Jøtul GF DV Allagash 300
Direct Vent Gas Heater
Manufactured and Distributed by:
Jøtul North America
55 Hutcherson Dr.
Gorham, Maine 04038
Certified Test Standards
This appliance complies with National Safety standards
and is tested and listed by Intertek Testing Services of
Middleton, Wisconsin to ANSI Z21.88-2019 / CSA 2.33-2019,
and CAN/CGA 2.17-M91.
Your stove has a unique serial number stamped on the
rating plate which is hung on the back. Please record
the serial number in the space below. You may also wish
to attach your purchase receipt to this page for future
reference.
MODEL NAME: Jøtul GF DV Allagash Gas Stove300
SERIAL NUMBER:_______________________________
DATE OF PURCHASE:____________________________
AUTHORIZED DEALER:__________________________
ADDRESS ___________________________________
PHONE: ____________________________________
INSTALLER:__________________________________
FUEL TYPE:____________________________________
FUEL CONVERSION: NO _______ YES_____
NOTES:________________________________________
______________________________________________
______________________________________________
Tuotetiedot
Merkki: | Jotul |
Kategoria: | Liesi |
Malli: | GF 300 DV Allagash |
Tarvitsetko apua?
Jos tarvitset apua merkille Jotul GF 300 DV Allagash esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Liesi Jotul Käyttöohjeet
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
Liesi Käyttöohjeet
Viimeisimmät Liesi Käyttöohjeet
25 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024