Jotul GF 300 BV Allagash Käyttöohje
Lue alta 📖 käyttöohje suomeksi merkille Jotul GF 300 BV Allagash (28 sivua) kategoriassa Liesi. Tämä opas oli hyödyllinen 3 henkilölle ja sai 4.5 tähden keskimäärin 2 käyttäjältä
Sivu 1/28
1
137945_22 GF 300 BV 01/22
Installation and
Operation Instructions
Jøtul GF 300 BV Ver. 2
Allagash
Natural Vent Gas Stove
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
– Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
– In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall
be installed in the same room as the
appliance.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or loss of life.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or
mobile home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is
supplied with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
2
137945_22 GF 300 BV 01/22
We recommend that
our gas products be
installed and serviced by
professionals who are
certified in the U.S. by
the National Gas stove
Institute® (NFI) as NFI Gas
Specialists.
58.68%
Jøtul GF 300 BV
Installation Requirements for the
Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GASFITTER WHEN
INSTALLED IN THE COMMONWEALTH OF
MASSACHUSETTS.
MA Approval Code G3-0817-12
1. If there is not one already present, on each
floor level where there are bedroom(s),
a carbon monoxide detector and alarm
shall be placed in the living area outside
the bedroom(s). The carbon monoxide
detector shall comply with NFPA 720
(2005 Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses the
appliance or equipment;
b) Be either hard-wired or battery
powered or both; and
c) Shall comply with NFPA 720 (2005
Edition).
3. A Product-approved vent terminal must
be used, and if applicable, a Product-
approved air intake must be used.
Installation shall be in strict compliance
with the manufacturer’s instructions. A
copy of the installation instructions must
remain with the appliance or equipment
at the completion of the installation.
THIS OWNER’S MANUAL PROVIDES INFORMATION TO ENSURE
SAFE INSTALLATION AND EFFICIENT, DEPENDABLE OPERATION
OF YOUR GAS STOVE. PLEASE READ THESE INSTRUCTIONS IN
THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE
USING OR SERVICING THIS APPLIANCE.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION
OF THIS APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION WILL VOID THE WARRANTY,
CERTIFICATION AND LISTING OF THIS APPLIANCE.
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED SERVICE AGENCY.
Suggested Tools for
Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shut-off valve -
T-Handle required in Massachusetts
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10 mm open end wrench
• 1/2”, 7/16” open end wrench
• Phillips head screwdriver
• Flat head screwdriver
• 1/4” nut driver
• Gloves
• Safety glasses
• Torx T-20 screwdriver
• Tin snips
PLEASE NOTE:
It is normal for smoke and odor to occur during
the initial stages of operation, depending upon
temperatures generated over time. This “curing”
condition can be alleviated by promoting fresh
air circulation within the immediate vicinity of
the appliance.
Based on CSA P.4.1-15
3
137945_22 GF 300 BV 01/22
Table of Contents
Service Tools .............................................2
Specifications 4 ............................................
General Information 5 ................................
Unpacking Your Stove ............................5
Safety Information 5 ..................................
Installation Requirements
Location 6 ................................................
Hearth Requirements 6 ........................
Clearances 7 .............................................
Mantel & Trim 7 ......................................
Alcove 7 ....................................................
Vent Requirements 8 ..................................
Fuel Conversion 11 ........................................
Gas Supply Connection 13 ..........................
Gas Pressure 14 ............................................
Log Set Installation 15 .................................
Flame Adjustment 16 ................................
Optional Wall Thermostat ....................16
Remote Control 16 .......................................
Decorative Pipe 17 .......................................
System Check 17 ...........................................
Stove Operation 18 ......................................
Maintenance 19 ...........................................
Annual Cleaning 19 .................................
Glass Replacement 19 .............................
Optional Blower 20 ...................................
Optional Antique Brick Kit 22 ..................
High Altitude Adjustment 23 ...................
Mobile Home Installation 23 ...................
Illustrated Parts Breakdown 24 ................
Replacement Parts List 25 ..........................
Warranty Statement 26 .............................
Lighting Instructions ............................ 27
Jøtul GF BV Allagash
Natural Vent Gas Stove
300
Manufactured and Distributed by:
Jøtul North America
55 Hutcherson Dr.
Gorham, Maine 04038
Test Standards
This appliance complies with National Safety
standards and is tested and listed by Intertek
Testing Services of Middleton, Wisconsin to
ANSI Z21.88-2019 • CSA 2.33-2019,
and CAN/CSA 2.17-M91.
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE
OR ITS COMPONENTS. ANY MODIFICATION
OR ALTERATION WILL VOID THE WARRANTY,
CERTIFICATION AND LISTING OF THIS APPLIANCE.
Your stove has a unique serial number stamped on the
rating plate which is hung on the back. Please record
the serial number in the space below. You may also wish
to attach your purchase receipt to this page for future
reference.
MODEL NAME: Jøtul GF 300 BV Gas Stove
SERIAL NUMBER:_______________________________
DATE OF PURCHASE:____________________________
AUTHORIZED DEALER:__________________________
ADDRESS ___________________________________
PHONE: ____________________________________
INSTALLER:__________________________________
FUEL TYPE:____________________________________
FUEL CONVERSION: NO _______ YES_____
NOTES:________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
Tuotetiedot
Merkki: | Jotul |
Kategoria: | Liesi |
Malli: | GF 300 BV Allagash |
Tarvitsetko apua?
Jos tarvitset apua merkille Jotul GF 300 BV Allagash esitä kysymys alla ja muut käyttäjät vastaavat sinulle
Liesi Jotul Käyttöohjeet
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
Liesi Käyttöohjeet
Viimeisimmät Liesi Käyttöohjeet
25 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
23 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024
16 Lokakuuta 2024