Thank you for purchasing the Quiet-Cool Series™ ICOMP-COOL Component Cooler.
Please read these instructions thoroughly before installing this product.
PRODUCT FEATURES
- Extends equipment life.
- Removes heat directly from the source.
- Up to ten individual ICOMP-COOLs can
be run from one power supply. 3-1/8”
[79 mm]
3-3/16”
[81 mm]
5/8” [16 mm]
SPECIFICATIONS
MODEL POWER
REQUIREMENTS CFM dBA @ 1 METER
ICOMP-COOL 7.5 VDC @ 70mA 8
Per Fan 19
ICOMP-COOL-E 7.5 VDC @ 70mA 8
Per Fan
ICOMP-COOL-3 7.5 VDC @ 210mA 8
Per Fan
19
24
- Fan turns on at 87ºF [30.5ºC] and turns off at 85ºF [29.4ºC]
- LED illuminates green when fan activates, and
red when fan deactivates
LED
Page 2
middl ea tlan tic.co m
m
i
d
dl
ea t
la
n
tic .
co
m
PARTS
FAN UNIT
QTY
- ICOMP-COOL 1
- ICOMP-COOL - 3 3
- ICOMP-COOL - E 0
ADHESIVE BACKED FEET
QTY
- ICOMP-COOL 8
- ICOMP-COOL - 3 24
- ICOMP-COOL - E 8
WIRE TIE MOUNT
- ICOMP-COOL 5
- ICOMP-COOL - 3 15
- ICOMP-COOL - E 5
QTY
POWER SUPPLY
QTY
- ICOMP-COOL 1
- ICOMP-COOL - 3 1
- ICOMP-COOL - E 0
WIRE TIE
- ICOMP-COOL 5
- ICOMP-COOL - 3 15
- ICOMP-COOL - E 5
QTY
JUMPER CORD
- ICOMP-COOL 0
- ICOMP-COOL - 3 2
- ICOMP-COOL - E 1
QTY
1) Locate the hot spot on your component. (FIGURE A)
2) Clean area with provided alcohol wipe.
3) Remove paper covering adhesive ring. (FIGURE B)
4) Position ICOMP-COOL with power jack facing rear of component.
(FIGURE C) Press down to adhere.
TIP: If your cabinet does not have doors or sides, you may prefer to
position the unit so the air flows in a different direction.
5) Select appropriate wall plug for your region and install in provided
power supply.
6) Connect ICOMP-COOL to power source using provided Power
Supply.
NOTE: Wire Ties and Wire Tie Mounts are provided for cable
management.
FIGURE A
ADHESIVE
RING
FIGURE B
FIGURE C
INSTALLATION
Page 3
NOTE: If extra clearance between components is required to
accommodate the ICOMP-COOL, apply Adhesive
Backed Feet on the feet of the upper component with
adhesive side up. (FIGURE D)
Two Feet are provided for each location, but only one
per location may be required.
ADHESIVE
FOOT
FIGURE D
ICOMP-COOL-3 INSTALLATION (FIGURE E)
1) Install individual ICOMP-COOL units on equipment as required.
2) Using provided Jumper Cords, chain individual ICOMP-COOL units together.
3) Connect Power Supply to power source.
FIGURE E
ICOMP-COOL-E INSTALLATION (FIGURE F)
1) Using provided Jumper Cord,
connect ICOMP-COOL-E to
pre-installed ICOMP-COOL.
FIGURE F

Tuotetiedot

Merkki: Middle Atlantic
Kategoria: Hardwarekoeling
Malli: ICOMP-COOL

Tarvitsetko apua?

Jos tarvitset apua merkille Middle Atlantic ICOMP-COOL esitä kysymys alla ja muut käyttäjät vastaavat sinulle




Hardwarekoeling Middle Atlantic Käyttöohjeet

Hardwarekoeling Käyttöohjeet

Viimeisimmät Hardwarekoeling Käyttöohjeet